Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 10 of 10 for “"passive pumping"”.
-
Passive pumping, evaporation based system for multiscale thermal management
… evaporation and benefits from the associated passive pumping with an application of a rooftop solar radiation barrier in mind. By directing the incoming energy towards the phase change of water, lower surface temperatures can be maintained thus reducing heat transfer into the structure by …
-
A microfluidic culture for two populations of dorsal root ganglia for differential staining
… such as temperature, which requires external pumping or other applied forces. We demonstrated a pump-free device that exploits the surface energy stored in a liquid droplet to pump liquid in the channels. The fluid was pumped by using two droplets of unequal sizes connected via fluid filled …
-
Novel Approaches to Prepare and Utilize SERS Substrates: Multiplex Microfluidics and Nanotransfer Printing
… under easily manipulated conditions. A facile passive pumping method is used to deliver samples into the channels under flowing conditions that are highly conducive for SERS measurments.</p> <p>Also an unconventional nanofabrication approach is modified to produce efficient SERS substrates. …
-
Study of neutral transport and plasma fueling in the HIT-SI3 and HIT-SIU experiments
… the performance of a set of existing passive pumping volumes was considered. To gain insight into the performance of these volumes, and the conditions of the edge plasma region, the plasma inside one of these volumes was characterized using a triple Langmuir probe. A 1D plasma-neutral …
-
Microfluidic impedance biosensors for monitoring cancer cell behaviors
… V-shaped cell capturing structures and uses a passive pumping method. Using microfluidics without the requirement of physical connections to off-chip pneumatics, the proposed biosensor is capable of capturing single cells on top of MEAs with an efficiency of 70% to 100% for subsequent …
-
Coupling electrochemistry and microfluidics for biosensor development
… that could otherwise be limited by external pumping equipment. Similarly, the strategies described for interfacing microfluidic devices with the reported electrode arrays and platinum microelectrodes could be applied to other silicon microchips to accomplish precise control of fluid delivery …
-
Study and design of minimally instrumented microfluidic unit operations for a portable biosensor: mixing, pumping, and reaction
… unit operations that combined together, passively deliver analyte to a local, evanescent array coupled (LEAC) sensor. Specifically, this dissertation is focused on minimally instrumented mixing, pumping, and heterogeneous reaction strategies regarding fluids confined to microchannels …
-
The Study of Vacuum-Driven Microfluidic Networks and Their Pumping Methods
… vacuum-driven microfluidic networks and their pumping methods for sample preparation and potential application in point-of-care testing. The components used in the vacuum-driven microfluidics are studied to understand how to design microfluidic networks using vacuum-driven pumping. …
-
An Analysis of Capillary Flow in Finite Length Interior Corners
… usually only found on earth. It also provides a passive pumping mechanism due to geometry of a conduit. The driving force for this flow is a pressure difference due to local surface curvature gradients. An alternative reasoning is that due to the geometrical constraints the interior corner …
-
Passive fluid management in micro direct methanol fuel cells
This thesis describes the development of a passive micro direct methanol fuel cell (µDMFC) with stable runtime over 15 hours. The passive µDMFC is a combination of a state-of-the-art passive cathode design with a newly developed passive anode fuel supply method. This method is based on a liquid …