Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 116 for “"passive samplers"”.

  1. Ammonia Sampling using Ogawa® Passive Samplers

    … to determine the efficacy of using the Ogawa® passive sampling device (PSD) to measure ammonia and to identify significant ammonia sources adjacent to Hillsborough and Tampa Bay. Ninety-four samplers were deployed over a 180-km2 area for two weeks in October 2001. Within the area sampled were …

    usf Repository record for Ammonia Sampling using Ogawa® Passive Samplers (opens in a new tab)

  2. Application of Passive Samplers for SARS-CoV-2 Wastewater Surveillance

    … composite sampling of wastewater using autosamplers is the preferred means for wastewater surveillance sample collection. Autosamplers however require a significant capital cost and furthermore some sampling locations are not amenable to autosampler deployment because of a lack of space and …

    ottawa-retro Repository record for Application of Passive Samplers for SARS-CoV-2 Wastewater Surveillance (opens in a new tab)

  3. SILICONE WRISTBAND PASSIVE SAMPLERS AND URINARY PHTHALATE METABOLITES IN CHILDREN WITH ASTHMA

    Background: Phthalates are endocrine disrupting chemicals ubiquitous in consumer products, personal care items, and building materials. Emerging evidence links phthalate exposure to respiratory inflammation and airway dysfunction, raising concern for children with pre-existing respiratory …

    jhu Repository record for SILICONE WRISTBAND PASSIVE SAMPLERS AND URINARY PHTHALATE METABOLITES IN CHILDREN WITH ASTHMA (opens in a new tab) Embargoed until 2027-05-01

  4. Silicone Wristbands as Passive Samplers for Quantitative Measurement of Wood Smoke Exposure

    Human exposure to biomass smoke is a health concern worldwide. Although many studies have measured particulate matter in wood smoke as a health concern, exposure to mutagenic and carcinogenic volatile and semivolatile compounds remains understudied. This research introduces a novel method of …

    montana Repository record for Silicone Wristbands as Passive Samplers for Quantitative Measurement of Wood Smoke Exposure (opens in a new tab)

  5. Silicone Wristbands as Passive Samplers for Quantitative Measurement of Wood Smoke Exposure

    Human exposure to biomass smoke is a health concern worldwide. Although many studies have measured particulate matter in wood smoke as a health concern, exposure to mutagenic and carcinogenic volatile and semivolatile compounds remains understudied. This research introduces a novel method of …

    montana-tech Repository record for Silicone Wristbands as Passive Samplers for Quantitative Measurement of Wood Smoke Exposure (opens in a new tab)

  6. Assessing Hyperlocal and Local Air Quality through Passive Samplers and Low-cost Monitors

    … domain in Louisville, Kentucky. Using a 60-site passive sampling network, annual and warm seasonal models (2019, 2021-2023) explained a large portion of spatial variability (Adjusted R2 = 0.56 – 0.76 for annual NOx, 0.56 – 0.63 for annual NO2, 0.57 – 0.71 for warm-season NOx, 0.49 – 0.59 for …

    wustl Repository record for Assessing Hyperlocal and Local Air Quality through Passive Samplers and Low-cost Monitors (opens in a new tab)

  7. Determination of groundwater velocity in-situ by using passive samplers at sediment water interface

    … and degradation coefficient. In this research, passive sampler (peepers) were used to determine the groundwater velocity insitu when the mass flux of the contaminants to surface water was low. This study suggested that the ability of the samplers to accurately capture produced tracer profiles …

    ttu Repository record for Determination of groundwater velocity in-situ by using passive samplers at sediment water interface (opens in a new tab)

  8. Assessing Diffusive Gradients in Thin Films Passive Samplers for PFAS Quantitation in Aqueous Systems

    Diffusive gradients in thin-films (DGT) passive samplers are an alternative to grab sampling for quantifying time-weighted average (TWA) concentrations of per- and polyfluoroalkyl substances (PFAS) in aqueous systems. DGTs may enable long-term PFAS site characterization in a more time and …

    arkansas Repository record for Assessing Diffusive Gradients in Thin Films Passive Samplers for PFAS Quantitation in Aqueous Systems (opens in a new tab)

  9. Assessing Occupational Exposure to Flame Retardants and Plasticizers using Silicone Passive Samplers and other Measurement Methods

    … facilities and nail salons using silicone passive samplers and other measurement methods, including dust collection and active air sampling. The thesis advances the understanding of the use of silicone passive samplers for measuring SVOC exposure in personal exposure monitoring and …

    toronto-retro Repository record for Assessing Occupational Exposure to Flame Retardants and Plasticizers using Silicone Passive Samplers and other Measurement Methods (opens in a new tab)

  10. Development and application of passive samplers for assessing air and freely dissolved concentrations of hydrophobic organic contaminants

    This research focuses on the use of passive sampling techniques to assess air concentration of hydrophobic organic contaminants (HOCs) such as the polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) around a confined disposal facility. An effective method for managing …

    ttu Repository record for Development and application of passive samplers for assessing air and freely dissolved concentrations of hydrophobic organic contaminants (opens in a new tab)

  11. Evaluation of perfluorinated compounds in sediment, water, and passive samplers collected from the Barksdale Air Force Base

    … were then compared to sediment and water column passive sampler data to determine if passive samplers could be used as a less invasive method for estimating PFC concentrations in the environment. The concentrations detected in sediment passive samplers were estimated to be more heavily influenced …

    ttu Repository record for Evaluation of perfluorinated compounds in sediment, water, and passive samplers collected from the Barksdale Air Force Base (opens in a new tab)

  12. Demonstration and Validation of the Use of Passive Samplers for Monitoring Soil Vapor Intrusion to Indoor Air

    … thesis documents a demonstration/validation of passive diffusive samplers for assessing soil vapor, indoor air and outdoor air concentrations of volatile organic compounds (VOCs) at sites with potential human health risks attributable to subsurface vapor intrusion to indoor air. The study was …

    waterloo Repository record for Demonstration and Validation of the Use of Passive Samplers for Monitoring Soil Vapor Intrusion to Indoor Air (opens in a new tab)

  13. Wristband Passive Samplers as Tools for Quantifying Chemical Exposure: Elucidating Mechanisms of Uptake and Expanding Target Chemicals

    … motivation for the use of silicone wristbands as passive samplers in chapter 1 and addresses these uncertainties which are outlined in the following specific chapters:2. Measurement of the effect of movement speed on SVOC uptake to unworn silicone wristbands. 3. Quantification of SVOC uptake from …

    duke Repository record for Wristband Passive Samplers as Tools for Quantifying Chemical Exposure: Elucidating Mechanisms of Uptake and Expanding Target Chemicals (opens in a new tab)

  14. APPLICATION OF PASSIVE SAMPLERS FOR EXPLORING REMEDIAL PROGRESS IN THE TORCH LAKE AOC AND INTERLAKE VARIABILITY OF PCBS

    … contamination and evolving restoration policy. Passive samplers deployed across sites and seasons (2024–2025) show total PCB concentrations ranging from below detection to 110 pg/L (mean = 16.8 pg/L), representing an approximate 90% decline since 2005. Comparisons with regional reference lakes …

    mtu Repository record for APPLICATION OF PASSIVE SAMPLERS FOR EXPLORING REMEDIAL PROGRESS IN THE TORCH LAKE AOC AND INTERLAKE VARIABILITY OF PCBS (opens in a new tab)

  15. Method Development for Quantifying Micropollutants in Water at Trace Levels with Diffusive Gradients in Thin-Films Passive Samplers

    … levels. Diffusive gradients in thin-films (DGT) passive samplers can achieve lower MDLs compared to grab sampling as they accumulate analyte mass over time through an exposure window of area, Ap. Here, DGT passive samplers were used to measure time-weighted average analyte concentrations (CDGT) …

    arkansas Repository record for Method Development for Quantifying Micropollutants in Water at Trace Levels with Diffusive Gradients in Thin-Films Passive Samplers (opens in a new tab)

  16. Application of diffusive gradient in thin-film passive samplers to assess mercury availability and mobility in a fresh water river system

    … of sediment, transportation, and processing. Passive sampling is an alternative technique that measures sediment porewater concentrations in-situ and without significant sample disturbance. One passive sampling technique for mercury in sediment porewater is Diffusive Gradient in Thin-Films …

    texas Repository record for Application of diffusive gradient in thin-film passive samplers to assess mercury availability and mobility in a fresh water river system (opens in a new tab)

Page 1 of 6