Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 14 of 14 for “"passivhaus"”.
-
Estimated Benefits of Achieving Passivhaus and Net Zero Energy Standards in the Region of Waterloo Residential Sector and the Barriers and Drivers to Achieve Them
… a higher building standard, such as the Passivhaus (PH) and Net Zero Energy (NZE). The profile of the building envelope, including the initial CO2 emissions was compared against the requirements of the PH and NZE standards, using the Residential Energy Efficiency Project dataset …
-
Hygrothermal analysis of wooden frame and cross-laminated timber walls for energy efficiency and durability in Bhutanese climate
… ASHRAE standards and 85.8 kWh/m2a by using Passivhaus building envelope in cold climates, with energy savings of 51% and 62%, respectively. For warm and humid climates, the proposed building has energy demand of 168.7 kWh/m2a by following prescriptive ASHRAE standard and 151.2 kWh/m2a for …
-
Practices and technological change: The unintended consequences of low energy dwelling design
… how everyday life is performed. Specifically, a Passivhaus housing development is adopted as a case study in investigating the everyday consequences of advancing dwelling design. Passivhaus is a German energy efficiency building standard, employing very different technologies relative to …
-
An Investigation of Climatically Responsive Ultra-Low Energy Housing in Rural Scotland: a Case Study
… of the studies use a customised version of the Passivhaus Planning Package, an industry leading energy quantification methodology for heating energy calculations. A series of studies define the design envelope for achieving regional solutions by quantifying the relationship between the variation …
-
Life Cycle Optimization of a Zero Carbon Building for CO2e, Energy, and Cost Using Stochastic Controls for an Energy System Integrating a Heat Pump, Solar Air Wall, PV, and a Smart Grid-integrated Thermal Storage (SGTS) Hydronic Battery
… cycle GWP by 18.3% (LEED 2009 certified), 60.7% (PassivHaus 9.30), 96.9% (net zero) and 97.2% (zero carbon) compared to a home built to Alberta Building Code 2014 (base model – BM) over an 80 year life cycle. LCA of the ZC laneway house found a 94.4% reduction in GWP compared to the BM. In the BM, …
-
PHPP2E+: Employing dynamic building simulation while pursuing passive house certification
… monthly energy balance tool provided by the Passivhaus Institut (PHI) to verify the performance of the building according to the certification criteria, but nowadays due to climate change and the improvement of hourly dynamic simulations, more detailed analysis of the thermal processes within …
-
The Application of EnerPHit Standard to Residential Tower Blocks in the UK
… EnerPHit standard, which is an adaptation of the Passivhaus standard for retrofit. Currently, no single high-rise building in the UK has achieved this standard. The research focuses on the case study of Wilmcote House, a social housing tower block in Portsmouth owned and managed by Portsmouth City …
-
Detailed simulation of the indoor environment to aid ventilation system design in low energy houses
… model was created based on monitored data from a Passivhaus development in Scotland. Acceptance criteria for calibrating the model were defined, addressing the current absence of specific guidelines for model calibration based on the monitored indoor environment. Then, a review of current …
-
Accounting for carbon impacts in buildings: a rating procedure
… made. This included a detailed LCA of a PassivHaus built house in Wales. The simplification uses information available in current regulatory data used in the design process. It was found that a 75% accuracy can be achieved from only 5% of input data. The detailed LCA showed that the most …
-
Exploring the Passive House Framework in Cooling-Dominated Climates
… is important to study the Passive House concept (Passivhaus), and certification framework established in 1996. Passive Houses have been reported to save between 70 - 90% of the energy typically used in (residential) buildings, whilst maintaining acceptable comfort conditions. However, whilst such …
-
Il recupero sostenibile nelle 3 scale: alloggio, edificio, quartiere. 3 diversi approcci progettuali
… energetici di riferimento europei: il modello Passivhaus tedesco, il modello Minergie svizzero e il modello Casa Clima italiano e di questi si sono studiate alcune tra le più note realizzazioni. E’ stato, inoltre, affrontato il tema del risparmio energetico in edilizia dal punto di vista del …
-
Impact of future climate change on the building performance of a typical Canadian single-family house retrofitted to the PassiveHaus
As a response to the global warming, building sector aims to be more energy efficient. The adoption of some energy efficient measures may have potential negative impacts on the building performance under a changing future climate. This study investigates the impact of future climate changes on the …
-
A critical analysis of the passive house standard for the climates of the United States
"A ""passive house"" is a building that ""can provide the necessary heating, cooling, and dehumidification through supply air ventilation"" (Schneiders 2009). This study demonstrates that when using current technologies and practices, the functional definition of passive house as defined above by …
-
Environmentální řešení budovy divadelního sálu a ateliérů v Brně
Diplomová práce má dva cíle: V prvním řeší projektovou dokumentaci pro stavební povolení pro novostavbu budovy divadelního sálu s přilehlými ateliéry v Brně. Objekt je samostatně stojící, podsklepený, s jedním podzemním a pěti nadzemními podlažími. Důraz je kladen zejména na spojení funkčních …