Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 944 for “"patch clamp"”.
-
Patch-clamp studies on schistosoma mansoni
Thesis (M.S.)--Michigan State University. Department of Zoology, 1990
-
INTEGRATED SILICON MICROPIPETTES FOR PATCH CLAMP APPLICATIONS
Patch clamping the electrophysiological properties of cells. Conventional patch clamp experiments require the careful manipulation of a glass micropipette to the membrane of an isolated cell under high power microscopy. Whilst the process is laborious, the exquisite sensitivity of the patch clamp …
-
Fluorescenční značení skleněných mikroelektrod pro systém patch clamp
… značenia sklenených mikroelektród pre systém patch clamp. Bližšie analyzuje možnosti vytvárania sklenených mikroelektród od výberu vhodného typu skla až po zostrojenie mikroelektródy, ktorá môže byť využitá v praxi pri experimentálnych meraniach. Etapy postupu vytvárania sklenených …
-
Automation of patch clamp investigations for neuro-physiological studies
<P>THE PATCH CLAMP TECHNIQUE IS AN IMPORTANT MEASUREMENT METHOD EMPLOYED IN THE AREA OF LIFE SCIENCES TO STUDY THE ELECTROPHYSIOLOGICAL RESPONSE OF CELLS WHEN SUBJECTED TO DIFFERENT STIMULI. A SUCCESSFUL PATCH ON ANY CELL IS DETERMINED BY 3 MAIN FACTORS, ONE OF WHICH IS THE SKILL OF THE PATCH CLAMP …
-
Walk-away automation of in-vitro patch-clamp electrophysiology
… for performing neuronal classification is patch-clamp recording, which allows single-cell profiling of neuronal morphology, electrical activity, genetic expression, and connectivity patterns; however the technique is highly manual and laborious, making it unsuitable for large-scale studies …
-
Development of planar patch clamp with potentiometric calcium ion-selective electrode
… gating the flow of ions in and out of the cell. Patch clamp technology has been the proven standard for fundamental studies of ion channel activities. However, the technique has some basic limitations: low throughput, time consuming nature of its process, need of highly skilled personnel and …
-
Silicon nanopore patch clamp device for measuring single ion channel activity
… the Nobel Prize for their invention of the patch clamp, which is based on the formation of a high resistance seal between a glass micropipette and a cell membrane. This transformative method allows low noise recording of current arising from single ion channels or from an entire cell and has …
-
TASK-5, a potential mitochondrial channel characterised by planar patch-clamp electrophysiology
… electron microscopy (TEM). Last, planar patch-clamping was performed on mitoplasts over-expressing TASK-5 to investigate whether the channel can elicit K+ currents. This was achieved by administrating a cocktail of channel blockers to mitoplasts and comparing residual current amplitudes …
-
Die Kinetik des heteromeren 5-HT3-Rezeptors: Untersuchungen mit Patch-Clamp-Technik und Computersimulationen
Der 5-HT3-Rezeptor gewinnt zunehmend pharmakologische Bedeutung, z.B. hinsichtlich der Wirkmechanismen von Antidepressiva. Diese wirken u.a. als 5-HT3-Rezeptor-Antagonisten oder hemmen die präsynaptische Serotonin-Wiederaufnahme. Darüber hinaus werden 5-HT3-Antagonisten in der Therapie des …
-
Binaural mechanism revealed with in vivo whole cell patch clamp recordings in the inferior colliculus
Many cells in the inferior colliculus (IC) are excited by contralateral and inhibited by ipsilateral stimulation and are thought to be important for sound localization. These excitatory-inhibitory (EI) cells comprise a diverse group, even though they exhibit a common binaural response property. …
-
Electrofisiología de células adrenocorticales: Estudio mediante el registro intracelular y la técnica de “patch clamp”
… iónica transmembrana mediante la técnica de “patch clamp”, incluyendo el diseño y construcción del equipo electrónico de registro. Este objetivo lo consideramos de gran importancia, no solo porque aporta una independencia conceptual y metodológica que es de gran importancia en nuestro medio, …
-
In vivo serial patch clamp robotics for cell-type identification in the mouse visual cortex
… and transform the highly manual art of obtaining patch-clamp electrophysiological recordings in vivo into a systematic, automated procedure. The patch clamp technique is the current gold standard for recording the intracellular electrical activity of individual cells and has the highest resolution …
-
Patch-Clamp Untersuchungen an Immunzellen: Beteiligung eines Ionenkanals als generelles Prinzip bei der Zellaktivierung durch mikrobielle Pathogenitätsfaktoren
… bacteria. In this work it is shown in patch-clamp experiments that the MaxiK channel is also activated by peptidoglycan (sPG), a cell wall component of Gram-positive bacteria, and the pro-inflammatory cytokine Interleukin-1 (IL-1). Cytokine release from human macrophages induced by each …
Page 1 of 48