Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 224 for “"peak value"”.

  1. Comparison of the force and torque transfer for different cam profiles

    … constant load applied to the groove cams, the peak value of the cycloidal cam's average torque was nearly 50% higher than the peak value of the sinusoidal cam. It was also observed that for the constant torque applied to the groove cams, the peak value of the force experienced by the follower …

    uoit Repository record for Comparison of the force and torque transfer for different cam profiles (opens in a new tab)

  2. A calculable impulse voltage calibrator

    … generates lightning impulses (LI) with known peak value (UP), front time (T1), and time to half value (T2); or switching impulses (SI) with known peak value (UP), time to peak (TP), and time to half value (T2). The peak voltages of the constructed devices range from 50 mV to 1000 V. The …

    aalto Repository record for A calculable impulse voltage calibrator (opens in a new tab)

  3. Avalanche Transistors And Diodes In A Transiecnt X-Ray Environment.

    … and incorporated in equivalent circuits. The peak value of the transient photocurrent increased up to the avalanche break­down voltage of the diode. An equivalent circuit is given for the region prior to breakdown, which indicates that this avalanche multiplied photocurrent can be inserted as …

    unm Repository record for Avalanche Transistors And Diodes In A Transiecnt X-Ray Environment. (opens in a new tab)

  4. Stable isotope stratigraphy across the Silurian-Devonian boundary in southern Oklahoma and subsurface west Texas

    … the Henryhouse-Haragan boundary that reaches a peak value (~ + 3.0%o) in the early Lochkovian Icrodiuspostwoschmidti zone. The 5'^C signature of the Frame Formation also shows a steady increase in 5'^C (~ + 3.0 %o) from the late Pridoli that reaches a peak value (~+ 5.0 %o) in the early …

    ttu Repository record for Stable isotope stratigraphy across the Silurian-Devonian boundary in southern Oklahoma and subsurface west Texas (opens in a new tab)

  5. Alternating currents in superconducting wires

    … niobium remained superconducting until the peak value of the 60 cps. magnetic field at some point on the wire surface had reached or exceeded the bulk critical field of niobium. For the lead alloy the peak value was higher than expected for pure lead. The d.c. transition currents were also …

    rice Repository record for Alternating currents in superconducting wires (opens in a new tab)

  6. Large Eddy Simulation and Wavelet Analysis of the Flow Field around a Surface Mounted Prism

    … The results show that the highest negative mean value of the pressure coefficient on the roof and the sides is about 30% larger in case two of turbulent inflow and takes place closer to the windward edge of the prism. Moreover, the pressure coefficients on the roof and sides of the prism in the …

    vt Repository record for Large Eddy Simulation and Wavelet Analysis of the Flow Field around a Surface Mounted Prism (opens in a new tab)

  7. Computational modelling of fluid load support in articular cartilage

    … models and the major finding were: • The peak value of fluid load support in both 2D and 3D fibrilreinforced models implementing DT-MRI data was increased to greater than 90% from around 60% in the isotropic poroelastic model, due to the reinforcement by collagen fibril. • The …

    whiterose Download PDF for Computational modelling of fluid load support in articular cartilage (opens in a new tab)

  8. Μελέτη της απόπτωσης υποπληθυσμών λευκοκυττάρων σε καρδιοχειρουργικούς ασθενείς

    … IL-8, IL-10, sFasL και TNFa) and its prognostic value for the postoperative development of cardiac patients.Methods: We studied 56 patients undergoing various cardiac surgery procedures with cardiopulmonary bypass (CPB). Apoptotic cells were double stained with Annexin V and propidium iodide and …

    greece Repository record for Μελέτη της απόπτωσης υποπληθυσμών λευκοκυττάρων σε καρδιοχειρουργικούς ασθενείς (opens in a new tab)

  9. The heat of mixing of diactone alcohol and water at 25 C

    … at 25°C over the entire concentration range. A peak value of 238 cal/mole solution was obtained at 0.67 mole fraction water the mixing of two moles water with one of diacetone alcohol.</p><p>Specific heat of diacetone alcohol-water mixtures was also measured at 25°C with the same apparatus.</p>

    njit Repository record for The heat of mixing of diactone alcohol and water at 25 C (opens in a new tab)

  10. Optimization of flight trajectories in a three-dimensional model of windshear flow field

    … the performance index being minimized is the peak value of the deviation of the absolute path inclination from a reference value; for the abort landing problem, the performance index being minimized is the peak value of the altitude drop. The resulting optimal control problems are Chebyshev …

    rice Repository record for Optimization of flight trajectories in a three-dimensional model of windshear flow field (opens in a new tab)

  11. Analysis of nonlinear RC op-amp oscillators utilizing phase space techniques

    … A design criterion is developed based upon the peak value of the output state variable and the input resistor to the op-amp. Describing function analysis demonstrates that the linearized differential equation closely follows a linear version of the nonlinear oscillator considered.</p>

    ut-knoxville Repository record for Analysis of nonlinear RC op-amp oscillators utilizing phase space techniques (opens in a new tab)

  12. Investigations into the xenon chloride excimer laser

    … nm laser output pulse had a fwhm of 20 ns and a peak power of 8.6 MW. When charged to 35 kV, the voltage inversion reached a peak of ~45 kV and dropped to zero in ~35 ns. The fwhm of the discharge current was 46 ns, with a peak current of 15.3 kA. The electron density in the discharge was …

    ubc Repository record for Investigations into the xenon chloride excimer laser (opens in a new tab) Download PDF for Investigations into the xenon chloride excimer laser (opens in a new tab)

  13. Pull-out behaviour of steel grid soil reinforcement in silty sand

    … angle but, it is not clarified whether the value of the friction angle should be taken as the peak value or the value at the critical state. Some of the published literature suggests that bearing resistance factor deduced from test results depends on overburden pressure which is …

    unsw Repository record for Pull-out behaviour of steel grid soil reinforcement in silty sand (opens in a new tab)

  14. Automatic Patent Classification Using Support Vector Machines And Its Applications

    … and 2007 shows that the quantity reaches its peak value in 2001 and follows a downward trend until 2006. Based on the patent identification result, we also run several economic analyses to verify the ABP development trend and investigate their characteristics.

    cornell Repository record for Automatic Patent Classification Using Support Vector Machines And Its Applications (opens in a new tab)

  15. The effect of whey protein on insulin and glucose responses in recreationally active males

    … as well as calculated area under the curve (AUC) values to compare differences between trials. WPH and WPC glycemic responses did not significantly differ from each other, but did differ from CHO (p<0.05). While peak insulin values were greatest following CHO ingestion (34.24±μIU/mL) (p<0.05), …

    twu Repository record for The effect of whey protein on insulin and glucose responses in recreationally active males (opens in a new tab)

  16. Conversion of liquid heptane to syngas through combustion in porous media

    … of the material properties. Various experimental values are compared to numerical results obtained from a porous media computational model. Hydrogen production increases with increasing equivalence ratio and mixture inlet velocity. However, hydrogen conversion efficiency reaches its peak value of …

    texas Repository record for Conversion of liquid heptane to syngas through combustion in porous media (opens in a new tab) Restricted access

  17. Studies of a xenon chloride laser

    … power of ≈ 7 MW. The discharge current reaches a peak value of 7.75 KA, with a rise time of 24 nsec, whereas the voltage reaches a maximum value of 29.1 KV, with a rise time of 111 nsec. By using a CO₂ Mach-Zehnder interferometer, the electron density was measured for the optimum mix …

    ubc Repository record for Studies of a xenon chloride laser (opens in a new tab) Download PDF for Studies of a xenon chloride laser (opens in a new tab)

  18. Experimental wave effect on vertical relative motion

    … carried out. A comparison of the most probable peak value of the different modes of motion indicates that the linear theory tends to overpredict.

    tamu Repository record for Experimental wave effect on vertical relative motion (opens in a new tab)

Page 1 of 12