Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"pelvic phantom"”.

  1. Development and Implementation of The Use of Optically Stimulated Luminescent Detectors In The Radiological Physics Center Anthropomorphic Quality Assurance Phantoms

    … trials. Anthropomorphic quality assurance (QA) phantoms are one tool the RPC uses to remotely audit institutions, which include thermoluminescent dosimeters (TLDs) and radiochromic film. The RPC desires to switch from TLD as the absolute dosimeter in the phantoms, to optically stimulated …

    uthsc Repository record for Development and Implementation of The Use of Optically Stimulated Luminescent Detectors In The Radiological Physics Center Anthropomorphic Quality Assurance Phantoms (opens in a new tab)

  2. Validation of a navigated hip replacement surgery system

    … a VICON movement analysis system. An aluminium pelvic phantom was machined with high accuracy to perform the experiments. Data were captured simultaneously from both OrthoPilot and VICON systems. Distances between the anatomical land marks, which defines the anterior pelvic plane on the pelvic …

    strathclyde Repository record for Validation of a navigated hip replacement surgery system (opens in a new tab)

  3. Real-time ultrasound bone segmentation and robust US-CT registration for surgical navigation of pelvic fractures

    Surgically repairing pelvic fractures is complex and includes intensive use of ionizing X-rays. The surgery is prone to screw insertion errors, which can harm the patient. We aim to alleviate these issues by proposing ultrasound (US), instead of X-rays, to guide the surgery. However, US images are …

    ubc Repository record for Real-time ultrasound bone segmentation and robust US-CT registration for surgical navigation of pelvic fractures (opens in a new tab) Download PDF for Real-time ultrasound bone segmentation and robust US-CT registration for surgical navigation of pelvic fractures (opens in a new tab)

  4. Development of a pelvic floor measurement tool and ultrasound compatible model to guide the design of patient-specific pessaries

    Pelvic Organ Prolapse (POP) management relies on subjective diagnostic measurements and inefficient trial-and-error pessary fitting. This thesis establishes a patient-specific engineering workflow to address these limitations. First, a mechanical introitus measurement tool was prototyped using …

    guelph Repository record for Development of a pelvic floor measurement tool and ultrasound compatible model to guide the design of patient-specific pessaries (opens in a new tab) Embargoed until 2027-02-24

  5. Robotic Ultrasound Tomography and Collaborative Control

    … sufficiently accurate for tomography based on pelvic phantom testing. Future steps in system verification and validation are discussed, as is incorporation into feasibility studies to test the potential and utility of the system for future prostate malignancy diagnosis and staging in vivo.

    jhu Repository record for Robotic Ultrasound Tomography and Collaborative Control (opens in a new tab)

  6. NOVEL PHANTOMS FOR ROBUST MRI-BASED RADIOMICS IN ONCOLOGY

    … by visual inspection of the images. In pelvic and breast cancer, MRI-based radiomics has been investigated for its potential to describe the tumour heterogeneity, thus improving diagnosis, prognosis and early therapy assessment, and it has shown promising results. However, the process …

    milano Repository record for NOVEL PHANTOMS FOR ROBUST MRI-BASED RADIOMICS IN ONCOLOGY (opens in a new tab)

  7. Characterization of Optically Stimulated Luminescent Detectors In Photon & Proton Beams For Use In Anthropomorphic Phantoms

    … for protons, and for remote anthropomorphic phantom irradiations. The OSLDs used were aluminum oxide (Al2O3:C) nanoDots from Landauer, Inc. (Glenwood, Ill.) measuring 10x10x2 mm3. A square, 20(L)x20(W)x0.5(H) cm3 piece of solid water was fabricated with pockets to allow OSLDs and TLDs to be …

    uthsc Repository record for Characterization of Optically Stimulated Luminescent Detectors In Photon & Proton Beams For Use In Anthropomorphic Phantoms (opens in a new tab)

  8. Range Adaptive Proton Therapy For Prostate Cancer

    … placed inside the rectum of an anthropomorphic pelvic phantom. Photodiode-generated current signal was generated as a function of proton beam distal depth, and the spatial resolution of this technique was calculated by relating the variance in detecting proton spills to its maximum penetration …

    uthsc Repository record for Range Adaptive Proton Therapy For Prostate Cancer (opens in a new tab)

  9. 2D transit dosimetry using electronic portal imaging device

    … planes measured for a reference beam with water phantoms of known thicknesses. Two sets of coefficients were derived separately from calibration dose planes measured with EPID and ionisation chamber (IC) in water. Consequently, with two sets of coefficients, the EPL of any attenuator can be …

    glasgow Download PDF for 2D transit dosimetry using electronic portal imaging device (opens in a new tab)