Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 83 for “"pencil-beam"”.
-
Enhancement and Evaluation of Proton Pencil Beam Spot Placement Algorithms
… modulated proton therapy (IMPT) in the form of pencil beam scanning (PBS) has shown improvement in treatment plan quality as compared to conventional proton and photon-based radiotherapy techniques. However, in IMPT maintaining a sharp lateral dose falloff is crucial for sparing organs at risk …
-
Fixed and Scannable Pencil Beam Antennas using Metasurfaces and Metamaterial Structures
… led to a renewed interest in simple and low cost pencil beam antennas, that are capable of generating fixed/scannable pencil beams. Although traditional active phased arrays are technologically suitable for these applications, there are cases where other alternatives are more attractive, …
-
A Methodology for the Design of Spaceborne Pencil-Beam Scatterometer Systems
… decades. These previous systems have been "fan-beam" scatterometers, where multiple antennas placed in fixed positions are used. The fan-beam scatterometer approach, however, has disadvantages which limit its utility for future missions. An alternate approach, the conically-scanning …
-
Clinical implementation of quality-assured and optimized pencil beam scanning proton therapy for moving targets
… motion that occurred during the dynamic beam delivery. The algorithm was experimentally validated and provided accurate results under realistic clinical conditions for peak-to-peak motion amplitudes of up to 15 mm. Following the clinical implementation, the first patients receiving a …
-
Analysis of 2-axis pencil beam sonar microbathymetric measurements of mine burial at the Martha's Vineyard Coastal Observatory
… larger, 16 total object investigation. A 2-axis pencil beam sonar was deployed concurrently with the mine to obtain microbathymetric measurements of the scour pit development and the progression of mine burial. Data correction techniques to correct for beam pattern induced bathymetry errors and a …
-
Development of a Patient Machine Time Model to Evaluate Dose Perturbation by Respiratory Tumor Motion in Pencil Beam Scanning Proton Radiation Therapy
<p>The pencil beam scanning (PBS) modality for delivering intensity modulated proton radiation therapy is being adopted quickly. Drawing from the dosimetric advantages provided by the Bragg Peak, PBS proton therapy has been shown to produce dose distributions with improved healthy tissue …
-
Assessment of single-spot TOPAS MC simulation for proton pencil beam scanning in homogeneous and heterogeneous media and quantification of dosimetric impact of CT metal artifact on IMPT and VMAT plans
Proton pencil beam scanning (PBS) radiation therapy has become thriving worldwide. The accuracy of proton dose calculation that based on proper modeling for each single scanning spot as well as accurate CT image data is crucial. The goal of this work is first to investigate the lateral dose profile …
-
THE EFFECTIVENESS OF DUAL ENERGY X-RAY ABSORPTIOMETRY TO NON-INVASIVELY DETERMINE BODY COMPOSITION OF HYBRID STRIPED BASS
… and scanned with a Hologic model QDR-4500A fan beam DXA. When compared to proximate analysis, results produced significant correlations and regression equations for: water and protein compared to lean, grams of fat, and ash compared to bone mineral composition. The second study utilized four …
-
Extending the QuikSCAT Data Record with the Oceansat-2 Scatterometer
… the Ku-band SCP dataset of conically scanning pencil-beam scatterometers begun by the Seawinds scatterometer flown on the QuikSCAT mission 1999-2009. As a standard SCP product, a temporal resolution enhancement technique for the scatterometer image reconstruction (SIR) algorithm is applied to …
-
Digital Baseband Processing of a Mills' Cross Array Antenna
… The processor uses time modulation to scan the pencil beam produced by the array in a raster-like fashion over the prescribed sector. The scheme uses within-pulse scanning in order to avoid the loss of power in the fan beams outside the area covered by the pencil beam. This processor provides …
-
Techniques in dosimetry and 3-D treatment planning for stereotactic radiosurgery / radiotherapy / Mostofa Heydarian.
A method of calculating beam data using sector-integration of Monte Carlo-generated pencil beam kernels has been proposed. This technique can be used both for circular and irregular fields, however it is more useful in calculating dosimetry parameters for irregular fields where the shape of …
-
A Comparative Analysis of Water-Equivalent Path Length of Tissue Samples using a Fast Monolithic Proton Radiography System
… and CT scanner compatible with clinical pencil beam scanning (PBS) gantries. In this presentation, I demonstrate recent work on animal tissue samples using this scanner, including pork shoulder, pork ribs, and an in-tact pig head. A comparative analysis of RSP between x-ray CT and proton …
-
Convolution and model-based dose calculation methods in radionuclide and external-beam photon therapy
… radionuclide therapy cases, and to develop a pencil-beam dose kernel based calculation method for external photon therapy that also accounts for local variations in tissue material densities in 3D space. The variability of biological uptake and clearance of the therapy agent were analyzed in …
-
A determination of multiple scattering for a negative pion beam
… on the dose distributions resulting from pion beams incident on thick targets. The use of negative pions in radiotherapy requires a detailed knowledge of the distribution of dose and biological effect. Thus it is important to have an accurate description for the lateral distributions of pions …
-
2d dose measurement using a flat panel EPID
… spectrum and phantom material using a 6MV pencil beam. We found that flat panel EPID scatter kernel has as much as 80% more scattering power than the water scatter kernel in the region 1 cm away from the center of a 6MV pencil beam. This confirms that a flat panel EPID behaves significantly …
-
Standards in clinical dual energy x-ray absorptiometry
… fracture. The original technology was based on a pencil beam x-ray source but later systems use a fan beam. Additional functionality includes measurement of hand BMD and vertebral fracture assessment (VFA). Smaller devices have also been developed to measure BMD at peripheral sites in the body. As …
-
Self-Stabilizing Switched Beam Offset Reflector (3SBOR) Antenna: 10GHz Prototype Antenna Solution for Mobile Radar and Communication Applications
… which normally prevents the use of a high gain, pencil beam antenna.Through the use of accelerometers and position filtering, the antenna constantly switches its beam in order to maximise directivity in the intended direction. As a proof of concept, a 10 GHz, single dimension dish was built and …
-
Multi-layer Strip Ionization Chamber for Proton Quality Assurance and Imaging
… modality. Proton treatment is delivered via pencil beam scanning (PBS) technique, in which a pencil beam scans the target spot-by-spot and layer-by-layer. An effective quality assurance (QA) device is needed to verify the quality of treatment dose delivery. Current clinical practice employs …
Page 1 of 5