Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 217 for “"perfusion imaging"”.
-
Peripheral perfusion imaging modeling
… for contrast-free ultrasonic per- fusion imaging. Novel pulsed-Doppler methods for perfusion imaging are val- idated using dialysis cartridges as perfusion phantoms. Techniques are exam- ined quantitatively at 5 and 12.5 MHz using phantoms with blood-mimicking fluid flow within cellulose …
-
Ultrasound tissue perfusion imaging
Enhanced blood perfusion in a tissue mass is an indication of neo-vascularity and potential malignancy. Ultrasonic pulsed Doppler imaging is a safe and economical modality for noninvasive monitoring of blood flow. However, weak blood echoes make it difficult to detect perfusion using standard …
-
A Comparison of Computational Perfusion Imaging Techniques
Dynamic contrast agent magnetic resonance perfusion imaging plays a vital role in various medical applications, including tumor grading, distinguishing between tumor types, guiding procedures, and evaluating treatment efficacy. Extracting essential biological parameters, such as cerebral blood flow …
-
Myocardial Perfusion Imaging With Rb-82 PET
Myocardial perfusion imaging (MPI) is an effective technique used to study the left ventricular ejection function (LVEF), myocardial perfusion, wall motion, and wall thickening. Positron emission tomography (PET) and single photon emission computed tomography (SPECT) are two modalities that can be …
-
Power doppler ultrasound for peripheral perfusion imaging
Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2023-12-04 without embargo terms
-
Perfusion imaging and tissue biomarkers for colorectal cancer
… in the treatment of colorectal cancer. Tumour perfusion and oxygenation is known to influence radiosensitivity and chemosensitivity. In this thesis, I propose that the evaluation of changes in tumour perfusion using perfusion CT (pCT) and dynamic contrast-enhanced (Dce) MRI can guide the …
-
Computed Tomography Perfusion imaging in acute ischemic stroke
… with maximum salvage of penumbra tissue. CTP perfusion imaging can be used to identify regions of core and penumbra after an acute stroke. This information increases confidence in stroke diagnosis, and can be used to guide management and for prognostication. The use of CTP before IV …
-
Electrical Impedance Tomography for Perfusion Imaging and Monitoring
… impedance tomography (EIT) is a medical imaging technology that uses boundary electrodes to inject stimulus currents and measure the resulting potential distributions. These potentials are measured using electrodes which are in turn used to reconstruct conductivity changes within the …
-
Quantifizierung der Myokardperfusion mittels Dual Saturation Time Perfusion Imaging
The Dual-Echo-Sequence to quantify myocardial perfusion was presented as an alternative to the prebolus-technique. The Arterial Input Function was determined using two different methods (‚KonFactor’- and ‚IndivFactor’-Method) in order to compare the calculated myocardial perfusion values with those …
-
A Novel Perfusion Imaging Strategy for the Ischaemic Limb
… in the major lower limb blood vessels. The imaging modalities used do not provide information on the microcirculation or muscle perfusion in the affected limb, the most important determinants of limb salvage in patients with PAD. An objective, non-invasive method for measuring and mapping …
-
An investigation into the limitations of myocardial perfusion imaging
Myocardial Perfusion Imaging (MPI) plays a very important role in the management of patients with suspected Coronary Artery Disease and its use has grown despite the shortcomings of the technique. Significant progress has been made in identifying the causes of these shortcomings and many solutions …
-
Quantitative Non-Contrast Perfusion Imaging Using Arterial Spin Labeled MRI
Arterial Spin Labeled (ASL) magnetic resonance imaging (MRI) is a promising non-contrast perfusion imaging method. ASL has been widely used in brains and has seen emerging applications in kidneys, lungs, and placentas. This work is focused on glioblastoma (GBM), a highly vascularized tumor, with …
-
MR Perfusion Imaging of the Human Brain With Deoxyhemoglobin Contrast
The advent of magnetic resonance imaging (MRI) has resulted in a paradigm shift in cerebral perfusion imaging, with the ability to image both perfusion and perfusion regulation at the millimeter-scale. The most widely used perfusion MRI method, dynamic susceptibility contrast (DSC), requires the …
-
HYPOXIA-INDUCED DEOXYHEMOGLOBIN; A CONTRAST AGENT FOR CEREBRAL PERFUSION IMAGING
Cerebral perfusion refers to the blood flow through the brain vasculature; a critical process that ensures enough oxygen and nutrients are delivered and waste products are removed. Advanced techniques for assessing cerebral perfusion use magnetic resonance imaging (MRI) and trace the passage of a …
-
Optimisation of vessel-selective magnetic resonance perfusion imaging and angiography
… status of brain tissue and cerebral arteries. Perfusion imaging and angiography offer information on blood flow to the tissue and through the brain-feeding arteries. A variety of imaging modalities exist to assess brain haemodynamics, including measures of cerebral blood flow and other …
-
Optimising combined angiographic, structural and perfusion imaging using arterial spin labelling MRI
… image both dynamic blood flow and tissue perfusion without contrast agents. However, ASL techniques face challenges such as limited spatial/temporal resolution, low signal-to-noise ratio (SNR), and susceptibility to motion artifacts. This thesis focuses on addressing these limitations to …
Page 1 of 11