Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 41 for “"peristaltic pumps"”

  1. Výpočtová a experimentální analýza cyklu peristaltického čerpadla využívaného v klinických aplikacích

    Peristaltic pumps (PP) play a critical role in various clinical applications such as dialysis, cardiopulmonary bypass, and extracorporeal membrane oxygenation, offering reduced haemolysis rates and fewer complications compared to centrifugal pumps. This study presents a comparative analysis of two …

    brno-tech Repository record for Výpočtová a experimentální analýza cyklu peristaltického čerpadla využívaného v klinických aplikacích (opens in a new tab)

  2. Design and Validation of an Accessible and 3D-Printable 24-Channel Peristaltic Pump for Cell Culture Research

    Peristaltic pumps are an essential part of biomedical research worldwide. The peristaltic pumps used for cell culture are precise and accurate machines which cycle media to and from cells during experiments. Commercial peristaltic pumps pose barriers for all labs due to expensive purchase and …

    queens Repository record for Design and Validation of an Accessible and 3D-Printable 24-Channel Peristaltic Pump for Cell Culture Research (opens in a new tab)

  3. Chemical flow control for injection-type agricultural sprayers

    … safely by reducing handling of chemicals. Peristaltic pumps are used to meter liquid chemical formulations on some current injection sprayers. Accuracies of two peristaltic pumps metering solution, emulsion and suspension liquid herbicide formulations were determined. The maximum error in …

    nebraska Repository record for Chemical flow control for injection-type agricultural sprayers (opens in a new tab)

  4. The Robotic Molecular Biologist -Automated Processing of Astrobiological Samples for Planetary Missions

    … platform is designed that is equipped with peristaltic pumps, solenoid valves, microfluidic chip, Microbial Activity MicroAssay (u-MAMA) and an Automated Nucleic Acid Extraction System (A-NECS). Further, a control algorithm is developed to perform an end-to-end analysis of DNA/RNA extraction …

    carleton Repository record for The Robotic Molecular Biologist -Automated Processing of Astrobiological Samples for Planetary Missions (opens in a new tab)

  5. Avaliação microscópica dos fragmentos ósseos obtidos por diferentes métodos de osteotomia e de irrigação em aloenxertos irradiados e congelados de coelho

    … osteotomy with trephine using saline from peristaltic pumps of surgical motor. Five bone pieces of each group were prepared for analysis on light microscopy (LM) and one on electronic scan electronic microscopy (SEM). On the SEM analysis edges surface, presence of microcracks and Smear …

    brazil-ufrn Repository record for Avaliação microscópica dos fragmentos ósseos obtidos por diferentes métodos de osteotomia e de irrigação em aloenxertos irradiados e congelados de coelho (opens in a new tab)

  6. Portable iso-dielectrophoresis system

    … RF frequency voltage source up to 24 V, syringe pumps, microscope, and computer. Much of this equipment is difficult to transport, making off-site sample collection of time-sensitive samples, such as blood, difficult. The miniaturization of the IDS system would allow measurements to take place at …

    mit Repository record for Portable iso-dielectrophoresis system (opens in a new tab)

  7. Modelling and characterisation of a 3D printed peristaltic pump

    Peristaltic pumps are positive displacement pumps that mechanically imitate the peristaltic process. The unique design and operation of the pumps allows it to have a wide range of applications, from blood pumps in heart-lung ma-chines to industrial cement pumps. Another possible application might …

    nwu-za Repository record for Modelling and characterisation of a 3D printed peristaltic pump (opens in a new tab)

  8. The effect of potential large-scale bioreactor environmental heterogeneities during fed-batch culture on the performance of an industrially-relevant GS-CHO cell culture, producing an IgG antibody

    … reactor (STR) and plug flow reactor (PFR). A peristaltic pump was used to continuously circulate cell culture from the STR through the PFR. Standard culture parameters were measured and flow cytometry was used to indicate cell viability and mode of cell death. The results essentially fell into …

    birmingham Repository record for The effect of potential large-scale bioreactor environmental heterogeneities during fed-batch culture on the performance of an industrially-relevant GS-CHO cell culture, producing an IgG antibody (opens in a new tab)

  9. Feedback control of a multi-input microbial fuel cell using observer-based linear quadratic regulation

    … contributing VFAs. Both inputs are dosed via peristaltic pumps controlled by an Arduino GIGA R1 WiFi. The reactor is modeled as an 875 mL CSTR with states VFA, EC, and pH, where VFA is unmeasured and estimated by a Luenberger observer. The B matrix is identified from two step-dose experiments …

    bu Repository record for Feedback control of a multi-input microbial fuel cell using observer-based linear quadratic regulation (opens in a new tab)

  10. Theory, design, and development of an open-source 3D printed peristaltic pump for microfluidics applications

    … designs have been developed or optimized. These pumps are generally capable of pumping flow in the range of 0.1-100s of microliters (µL) per minute, with the goal of pumping fluid with an extremely consistent flow rate. These pumps include, but are not limited to, peristaltic, syringe, membrane, …

    alaska Repository record for Theory, design, and development of an open-source 3D printed peristaltic pump for microfluidics applications (opens in a new tab)

  11. Estudo da inativação microbiana em água utilizando um reator UV-C

    … circulates by mechanic agitation impelled by two peristaltic pumps. The UV-C irradiation source was based on 6 units of 30 W germicide lamps. In this study, operation was investigated in different volumes (1, 2, 5, and 15 L), under constant flow rate of 1 L/min of fluid exposure to light, for 60 …

    brazil-ufscar Repository record for Estudo da inativação microbiana em água utilizando um reator UV-C (opens in a new tab)

  12. Design of Counter-current Tangential Chromatography to Improve Resin Lifetime and Operational Simplicity

    … The results indicate that the shear caused by peristaltic pumps and hollow fibres caused an average size reduction of 5% in both synthetic and agarose resins. However, the agarose-based resin had significantly deformed. Both resins exhibited a deviation of 5% from their original dynamic binding …

    ucl Repository record for Design of Counter-current Tangential Chromatography to Improve Resin Lifetime and Operational Simplicity (opens in a new tab)

  13. A Study Into Life Modelling for Elastomeric Tubes

    The performance of a tube within a peristaltic pump is as a result of complex interactions between material, the process used to produce the tube, the pump it is in and the environment to which it is subjected. This research examines a possible methodology for the development of life modeling for …

    the-open-u Repository record for A Study Into Life Modelling for Elastomeric Tubes (opens in a new tab)

  14. Analysis of expedited chromatographic separation systems for application to the decommissioning of nuclear facilities

    … through the columns being achieved using peristaltic pumps. Sr separation was found to be largely unaffected by increasing the flowrates up to those capable by the separator, and chemical recoveries of over 90 % were achieved. Pu, Th and U separation using three chromatographic materials …

    soton Repository record for Analysis of expedited chromatographic separation systems for application to the decommissioning of nuclear facilities (opens in a new tab)

  15. Development of a microfluidic based analytical system for copper monitoring in environmental water samples

    … system was developed incorporating miniaturised peristaltic pumps, a microfluidic plastic manifold and a compact photomultiplier tube for CL detection. Experimental conditions including reagent concentrations and flow rates were optimised and the system was found to produce linear results for …

    dcu Repository record for Development of a microfluidic based analytical system for copper monitoring in environmental water samples (opens in a new tab)

  16. Design of Medical Devices Involving Multi-disciplinary Processes and Based on Fundamental Physical Principles

    … second study is the first known effort to design peristaltic pumps using the principles of fluid-structure interaction. The time-dependent mechanics of peristaltic pumping were utilized to determine the deformations and pressures in the flexible-walled plastic tubing. The change of volume of the …

    umn Repository record for Design of Medical Devices Involving Multi-disciplinary Processes and Based on Fundamental Physical Principles (opens in a new tab)

  17. Continuous Production Of Raloxifene Hydrochloride Loaded Nanostructured Lipid Carriers Using Hot-Melt Extrusion Technology

    … like feeding rates for the volumetric feeder and peristaltic pumps, were optimized. A screw speed of 100 rpm and a barrel temperature of 85 °C, were used in the extrusion process. Characterization of the NLCs involved assessment of particle size, PDI, zeta potential, entrapment efficiency, and …

    mississippi Repository record for Continuous Production Of Raloxifene Hydrochloride Loaded Nanostructured Lipid Carriers Using Hot-Melt Extrusion Technology (opens in a new tab)

  18. Establishment of dynamic culture conditions for the fabrication of advanced in vitro tissue models.

    … medium in culture circuits was generated by peristaltic pumps, which can be operated with a self-built control unit. Culture chambers for different applications were computer-assisted designed, characterized by computational fluid dynamics and subsequently manufactured either by CNC milling …

    fu-berlin Repository record for Establishment of dynamic culture conditions for the fabrication of advanced in vitro tissue models. (opens in a new tab)

  19. The development and evaluation of a microprocessor-controlled bioreactor for use in developing countries

    … system for switching control devices (heater, peristaltic pumps); 4 -" Four interface cards to connect the parameter sensors. This system has the advantage that it is based on well established (though not state-of-the-art) microelectronic technology (Z80 chips) widely available in the world at …

    st-andrews Repository record for The development and evaluation of a microprocessor-controlled bioreactor for use in developing countries (opens in a new tab)

  20. Design and characterisation of a parallel miniaturised bioreactor system for mammalian cell culture

    … can conduct continuous feeding using built-in peristaltic pumps, maintaining the glucose concentration in the culture at approximately 2.0 g/L after initiation of feeding. The MBR described here potentially provides a valuable and effective tool for process optimisation and is capable of …

    ucl Repository record for Design and characterisation of a parallel miniaturised bioreactor system for mammalian cell culture (opens in a new tab)

Page 1 of 3