Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 156 for “"permeameter"”.

  1. Design and calibration of a Klinkenberg permeameter, The

    Includes bibliographical references.

    colo-mines Repository record for Design and calibration of a Klinkenberg permeameter, The (opens in a new tab)

  2. Design and Construction of a High-Frequency Permeameter

    Communications are currently progressing toward higher frequency ranges. Devices like transmitters and receivers, which make use of components like inductors, are the foundation of communications. Inductance plays a critical role in the performance of these devices and material characterization is …

    cornell Repository record for Design and Construction of a High-Frequency Permeameter (opens in a new tab)

  3. Assessing the Transient Flow Behavior in Falling-head Permeameter Tests

    … to determine K, one of which is falling head permeameter (FHP). In FHP, determining K involves two steps: measuring hydraulic head change over time and calculating the K value. In the past, calculating K was done using Darcy's Law, which states linear correlation between the flux and the …

    tamu Repository record for Assessing the Transient Flow Behavior in Falling-head Permeameter Tests (opens in a new tab)

  4. An evaluation of base soil-filter compatibility using a triaxial permeameter

    … the last 70 years. A novel and improved triaxial permeameter is used to test base soil-filter grain size ratios (D₁₅/d₈₅) close to the limit of filter incompatibility. The configuration and operation of the test device are described. Thereafter, data are reported for select combinations of base …

    ubc Repository record for An evaluation of base soil-filter compatibility using a triaxial permeameter (opens in a new tab) Download PDF for An evaluation of base soil-filter compatibility using a triaxial permeameter (opens in a new tab)

  5. A laboratory permeameter study of geotextile-soil retention in cyclic flow

    … flow reversal is evaluated using two rigid-wall permeameters: a small bench-mounted device, and a large floor-mounted device. Analysis of the results addresses the effects of specimen size (small and large), sidewall friction and stress distribution, and examines the influence of filter ratio …

    ubc Repository record for A laboratory permeameter study of geotextile-soil retention in cyclic flow (opens in a new tab) Download PDF for A laboratory permeameter study of geotextile-soil retention in cyclic flow (opens in a new tab)

  6. Determination of the hydraulic characteristics of unsaturated soils using a centrifuge permeameter

    … of unsaturated soils using a centrifuge permeameter was developed in this study. Specifically, the centrifuge permeameter is used to determine the water retention curve (WRC), which quantifies the energy required to retain water in the soil pores during wetting and drying, and the …

    texas Repository record for Determination of the hydraulic characteristics of unsaturated soils using a centrifuge permeameter (opens in a new tab)

  7. Evaluation of HMA laboratory permeability using the Karol-Warner Flexible Wall Permeameter

    … consisted of using a Karol-Wamer Flexible Wall Permeameter to evaluate the permeability of eight Superpave™-designed mixes and nine Marshall designed mixes produced in 1999 and 2000.</p> <p>The focus of this study was to evaluate the correlation between field and laboratory measurements of …

    ut-knoxville Repository record for Evaluation of HMA laboratory permeability using the Karol-Warner Flexible Wall Permeameter (opens in a new tab)

  8. Evaluation of the field permeability of HMA using the NCAT tiered permeameter

    … used for this study was a tiered field permeameter, which was developed at the National Center for Asphalt Technology (NCAT). The objectives of this study were to document the permeability of HMA in Tennessee, and to evaluate the merits of using the NCAT tiered permeameter (see Figure 1) …

    ut-knoxville Repository record for Evaluation of the field permeability of HMA using the NCAT tiered permeameter (opens in a new tab)

  9. On the feasibility of mounting bender elements in a flexible wall permeameter

    … the feasibility of equipping a flexible wall permeameter (FWP) with bender elements in order to measure shear wave velocity. Bender elements were designed and fabricated with a custom mounting system and a FWP was upgraded to accommodate the bender elements. The study was devised to determine …

    ubc Repository record for On the feasibility of mounting bender elements in a flexible wall permeameter (opens in a new tab) Download PDF for On the feasibility of mounting bender elements in a flexible wall permeameter (opens in a new tab)

  10. Utilization of the Air Permeameter to Determine the Intrinsic Permeability of in Situ Soil

    The first agricultural crops were grown in open areas that required minimum labor to prepare the soil for tillage. As other settlers followed, trees were cleared from the forested areas to open additional land to cultivation. The rocks and stones were removed from the fields to facilitate farming …

    sdstate Repository record for Utilization of the Air Permeameter to Determine the Intrinsic Permeability of in Situ Soil (opens in a new tab)

  11. The Effects of Permeameter Size and Wet-Dry Cycling on the Hydraulic Conductivity of Compacted Clay

    Over the past few decades increased public attention and concern has been focused on waste disposal. Historical practices included disposal in un-engineered dumps, which threatened human health and the environment and sparked an evolution in disposal facility engineering beginning in the 1950's and …

    sdstate Repository record for The Effects of Permeameter Size and Wet-Dry Cycling on the Hydraulic Conductivity of Compacted Clay (opens in a new tab)

  12. Protective laboratory measures for the flexible wall permeameter and the Atterberg limits tests using hazardous and toxic chemicals

    … wastes, are developed for the Flexible Wall Permeameter and the Atterberg Limits Tests. The tests were evaluated in detail to determine the critical points at which the technician would be exposed to the hazardous and/or toxic permeant. It was found that the following safety measures should …

    njit Repository record for Protective laboratory measures for the flexible wall permeameter and the Atterberg limits tests using hazardous and toxic chemicals (opens in a new tab)

  13. Tracking changes in hydraulic conductivity of soil reclamation covers with the use of air permeability measurements

    … this project was to design a prototype field air permeameter that can be used to track changes in the hydraulic conductivity within soil covers with time. The evolution of soil structure in reclamation soil covers at the Syncrude Canada Ltd. oilsands mine is currently being studied. The Guelph …

    sask Repository record for Tracking changes in hydraulic conductivity of soil reclamation covers with the use of air permeability measurements (opens in a new tab)

  14. Development and Test of a High Induction Permeameter with a Single Magnetizing Coil Surrounding the Pole Pieces and Specimen, and with Forced Draft Cooling

    … high magnetizing forces. It is believed that the permeameter described will be suitable for the commercial testing of magnetic materials used in electrical machinery. In addition, the magnetic properties of a specimen of welding rod and one of cold rolled steel have been investigated for values of …

    marquette Repository record for Development and Test of a High Induction Permeameter with a Single Magnetizing Coil Surrounding the Pole Pieces and Specimen, and with Forced Draft Cooling (opens in a new tab)

  15. Soil Air Permeability and Saturated Hydraulic Conductivity: Development of Soil Corer Air Permeameter, Post-fire Soil Physical Changes, and 3D Air Flow Model in Anisotropic Soils

    … This study presents the development of an air permeameter which is suitable for desert soils. The Soil Corer Air Permeameter (SCAP) is compatible with a standard soil corer and employs digital components to measure flowrates under low-pressure gradients to improve accuracy, ease of use, and …

    arizona-thes Repository record for Soil Air Permeability and Saturated Hydraulic Conductivity: Development of Soil Corer Air Permeameter, Post-fire Soil Physical Changes, and 3D Air Flow Model in Anisotropic Soils (opens in a new tab)

  16. Unsaturated flow in tailings

    … in a laboratory environment. The Modified Permeameter was built based on a permeameter used by Meerdink et al (1996) which was used with compacted clay samples. The modifications include using a large size sample; the ability to accommodate mobile sensors to alleviate the problems …

    ottawa-retro Repository record for Unsaturated flow in tailings (opens in a new tab)

  17. The hydraulic conductivity and adsorptivity of clay barrier materials containing organoclay

    … materials were compacted, placed in a rigid-wall permeameter, and permeated with 0.01 M CaSO4 or 0.01 M CaCl2, and also with dilute solutions of the test chemicals. Air pressure was used to create hydraulic head through the permeameter, and k of the clay barrier materials with and without …

    ubc Repository record for The hydraulic conductivity and adsorptivity of clay barrier materials containing organoclay (opens in a new tab) Download PDF for The hydraulic conductivity and adsorptivity of clay barrier materials containing organoclay (opens in a new tab)

Page 1 of 8