Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 71 for “"phantom study"”.
-
Moving Phantom Study of Stereotactic Body Radiation Therapy for Lung Cancer
… we performed a systematic evaluation using phantoms that simulated motions from real patients (irregular motions) as well as sinusoidal motions (regular motions). The irregular patterns investigated in this study were of two types: small range irregular breathing motions (=10mm) and large …
-
Assessment of fetoscopic tracheal occlusion using ultrasound images in phantom study
Congenital Diaphragmatic Hernia (CDH) is a birth defect that affects approximately 1 in 2000-5000 neonates. Most of the CDH cases are isolated, which means that affected individuals have no other major malformations. The diaphragm is a muscle that separates the chest from the abdomen. Incomplete …
-
A Phantom Study of In-beam PET Imaging for Proton Beam Range Verification
… activity distribution and activity range. This study investigates the feasibility, accuracy and precision of the activity range measurement with a high-performance compact PET prototype system for in-beam PET imaging. An experiment with a homogeneous PMMA phantom and several Monte Carlo …
-
Toward Characterization of Diseased Vascular Structures Using Noncontact Photoacoustic and Laser-Ultrasound Imaging: A Phantom Study
… procedure is chosen. Experiments on tissue phantoms were conducted with healthy and diseased artery surrogates embedded. All imaging was accomplished using noncontact, noninvasive PA and LU imaging. Through implementation of geophysical image processing techniques, improved image resolution …
-
The Advantage of Digital Tomosynthesis for Pulmonary Nodule Detection concerning Influence of Nodule Location and Size: Phantom Study
… were inserted into 8 different area of lung phantom classified as danger or non-danger zone. All 96 cases in which SPNs were inserted underwent examinations of 3 modalities at the same time. Additional 96 examinations were done to serve as a normal control using the same thoracic phantom. …
-
Application of a High‑Resolution Computed Radiography System in Detecting an Iodinated X‑ray Contrast Agent: Small Animal Phantom Study
… Omnipaque‑240, an iodinated contrast agent, in a phantom mimicking small animal tumor model. The first phase of the project was dedicated to a comprehensive assessment of CR image quality by measuring presampled Modulation Transfer Function (MTF), Noise Power Spectrum (NPS), Relative Standard …
-
A Phantom Study for Attenuation Change and Detection of Calcification in Lung Nodules According to Variation of Examination Techniques in Low Dose CT
… standard-dose CT. Material and Methods : A chest phantom containing artificial nodules was scanned with 64-detector-row and 128-detector-row CT scanners using a standard and various low-dose settings with iterative reconstruction. Mean attenuation of nodules and image noise were compared between …
-
Evaluation of the effect of breast implants on the accuracy of the CT attenuation Correction (CTAC) map for SPECT/CT myocardial perfusion imaging: a phantom study
… and without three sizes of breast implant, ina phantom study. The first experiment used a diagnostic CT scanner to design the method. Thesecond experiment was carried out in a clinical centre using the CT components of a SPECT/CTscanner to assess the impact of three different breast implants on …
-
Patient-specific quality assurance for IMRT
… part of the IMRT treatment process. This study evaluated two different QA modalities, a heterogeneous RANDO phantom and the MatriXX Detector. The RANDO phantom study evaluated the dosimetric accuracy of a helical TomoTherapy system which resulted in a benchmark being established for …
-
Focused Ultrasound Treatment of Glioblastoma
… GB resection surgeries. Also presented here is a phantom study for a commercial magnetic resonance guided focused ultrasound system, the RK-300, which has the ability to perform most of the therapies mentioned above. The phantom study confirms the functionality of the system, which after lying …
-
Coronary Wall Imaging Using Coronary CT Angiography
… the main focus of the current thesis. The first study of this thesis focused on choosing the optimal tube current and voltage. A coronary plaque phantom was scanned on a wide volume CT. Spatial resolution, contrast resolution, and vessel wall thickness were measured at different x-ray tube …
-
Lu-177 Automated Quantification Capabilities of Siemens Symbia Intevo 16.
… applicable patient uptake range, a NEMA phantom study was designed. Prior to the phantom study, the accuracy of the dose calibrator and deadtime effects were addressed. Optimal measurement conditions for Lu-177 in a vial and syringe were determined; both are clinically relevant and …
-
Validation of calypso surface beacons for deep inspiration breath hold radiotherapy
… of Calypso surface beacons while tracking a phantom in motion and to quantify effects of eddy currents in the presence of metallic objects, (b) to validate the use of the Calypso surface beacon as a method of tracking chest wall motion in volunteers with under 5 mm total uncertainty, and (c) …
Page 1 of 4