Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 6 of 6 for “"phase conductors"”.

  1. ΣΥΜΒΟΛΗ ΣΤΟΝ ΥΠΟΛΟΓΙΣΜΟ ΗΛΕΚΤΡΟΜΑΓΝΗΤΙΚΩΝ ΔΥΝΑΜΕΩΝ ΚΑΙ ΑΠΩΛΕΙΩΝ ΣΕ ΤΡΙΦΑΣΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΜΕ ΜΕΤΑΛΛΙΚΟΥΣ ΜΑΝΔΥΕΣ

    … ELECTROMAGNETIC FORCES ACTINGON THE PHASE-CONDUCTORS AND THE ALUMINIUM SHELL OF A THREE-PHASE METAL GLAD ARRANGEMENT ARE FIRST CALCULATED. THE CONDUCTORS ARE FILAMENTARY OR THIN HOLLOW CYLINDERS AND THE SKIN EFFECT IS NOT TAKEN INTO ACCOUNT FOR THE CURRENT DISTRIBUTION AT THE …

    greece Repository record for ΣΥΜΒΟΛΗ ΣΤΟΝ ΥΠΟΛΟΓΙΣΜΟ ΗΛΕΚΤΡΟΜΑΓΝΗΤΙΚΩΝ ΔΥΝΑΜΕΩΝ ΚΑΙ ΑΠΩΛΕΙΩΝ ΣΕ ΤΡΙΦΑΣΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΜΕ ΜΕΤΑΛΛΙΚΟΥΣ ΜΑΝΔΥΕΣ (opens in a new tab)

  2. ΕΠΙΛΥΣΗ ΤΟΥ ΜΗ ΓΡΑΜΜΙΚΟΥ ΠΡΟΒΛΗΜΑΤΟΣ ΤΩΝ ΠΟΛΛΩΝ ΡΕΥΜΑΤΟΦΟΡΩΝ ΑΓΩΓΩΝ ΜΕ ΤΗ ΜΕΘΟΔΟ ΠΕΠΕΡΑΣΜΕΝΩΝ ΣΤΟΙΧΕΙΩΝ

    … METHOD IS USED FOR THE FIELD COMPUTATION IN A 3-PHASE GAS INSULATED CABLE. THE PHASE CONDUCTORS CARRY SINUSOIDAL CURRENTS IN A STEADY-STATE AND BALANCED CONDITION. BOTH SYMMETRICAL AND NON-SYMMETRICAL CONDUCTOR ARRANGEMENTS ARE EXAMINED, TAKING INTO ACCOUNT THE REAL GEOMETRICAL AND PHYSICAL …

    greece Repository record for ΕΠΙΛΥΣΗ ΤΟΥ ΜΗ ΓΡΑΜΜΙΚΟΥ ΠΡΟΒΛΗΜΑΤΟΣ ΤΩΝ ΠΟΛΛΩΝ ΡΕΥΜΑΤΟΦΟΡΩΝ ΑΓΩΓΩΝ ΜΕ ΤΗ ΜΕΘΟΔΟ ΠΕΠΕΡΑΣΜΕΝΩΝ ΣΤΟΙΧΕΙΩΝ (opens in a new tab)

  3. Lightning protection of substations and switchyards based on streamer flow theory

    … a given three-dimensional array of shield wires, phase conductors and major electrical equipment on the ground.</p><p>The data obtained indicated that a simple 30 degree criterion is not satisfactory. A curve was obtained that showed that the higher a transmission line is moved above the ground, …

    ut-knoxville Repository record for Lightning protection of substations and switchyards based on streamer flow theory (opens in a new tab)

  4. ADVANCEMENTS IN LOAD FLOW TECHNIQUES FOR RADIAL DISTRIBUTION SYSTEMS

    … by the number of buses or the RIX ratio of the conductors but is adversely affected by the load sensitivity to bus voltage, the level of loading and the number of levels in the distribution system. In view of these shortcomings, a modification was made to this load flow method such that the …

    nus Repository record for ADVANCEMENTS IN LOAD FLOW TECHNIQUES FOR RADIAL DISTRIBUTION SYSTEMS (opens in a new tab) Download file for ADVANCEMENTS IN LOAD FLOW TECHNIQUES FOR RADIAL DISTRIBUTION SYSTEMS (opens in a new tab)

  5. Ocelový příhradový stožár 4x110kV

    Cílem této bakalářské práce je návrh nosné ocelové konstrukce příhradového stožáru elektrického vedení 4 x 110 kV. Prostorová skladba nosné konstrukce je navržena v souladu s požadavky na zabezpečení účelu, jemuž má objekt sloužit – přenosu elektrické energie. Nosná konstrukce stožáru je navržena z …

    brno-tech Repository record for Ocelový příhradový stožár 4x110kV (opens in a new tab)