Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 70 for “"phase correction"”.

  1. A Phase Correction Technique Based on Spatial Movements of Antennas in Real-Time (S.M.A.R.T.) for Designing Self-Adapting Conformal Array Antennas

    This research presents a real-time adaptive phase correction technique for flexible phased array antennas on conformal surfaces of variable shapes. Previously reported pattern correctional methods for flexible phased array antennas require prior knowledge on the possible non-planar shapes in which …

    ndsu Repository record for A Phase Correction Technique Based on Spatial Movements of Antennas in Real-Time (S.M.A.R.T.) for Designing Self-Adapting Conformal Array Antennas (opens in a new tab)

  2. High Resolution Acetic Acid Survey and Water Vapor Radiometer

    … are severely affected by atmospheric conditions. Phase correction is a technique to obtain high quality data and achieve great scientific goals. For our acetic acid survey, a better phase correction technique can not only detect weaker transitions of large molecules, but also increase the map …

    uiuc Repository record for High Resolution Acetic Acid Survey and Water Vapor Radiometer (opens in a new tab)

  3. Exploring the challenges of a far-infrared post-dispersed polarising Fourier transform spectrometer

    … FTS and grating spectrometer. The challenges of phase correction given the narrow bandwidth of the PDPFTS were explored and a technique was developed for reliable phase correction. The results show that the PDPFTS works as predicted, and allows one to recover a broadband spectrum at high …

    lethbridge Repository record for Exploring the challenges of a far-infrared post-dispersed polarising Fourier transform spectrometer (opens in a new tab)

  4. Spectral characterization of the Herschel SPIRE photometer

    … A detailed discussion is included on FTS phase correction, with results presented from the optimization of an enhanced Forman phase correction routine developed for this work. This thesis discusses the design, verification, and use of the hardware and software provided by Dr. Naylor's …

    lethbridge Repository record for Spectral characterization of the Herschel SPIRE photometer (opens in a new tab)

  5. Semiclassical analysis of vibroacoustic systems

    … method of Bogomolny to calculate semiclassical phase correction terms is followed for the free edge boundary condition and a phase correction is found that improves in accuracy on the previously thought value and includes contributions from lower order wavenumber and boundary curvature …

    soton Download PDF for Semiclassical analysis of vibroacoustic systems (opens in a new tab)

  6. Experimental study of stimulated Brillouin scattering in open cells and multimode optical fibres.

    … (SBS) were performed by performing optical phase conjugation in open cells and multimode optical fibres using a Q-switched, pulsed Nd:YAG laser (λ = 1.064μm). Experiments were done with test tubes that contained two SBS liquids - Fluorinert and Acetone, and multimode optical fibres with …

    adelaide Repository record for Experimental study of stimulated Brillouin scattering in open cells and multimode optical fibres. (opens in a new tab)

  7. Implementation of Range Autofocus for SAR Radar Imaging

    … an autofocus technique used to correct for phase error due to non-linearities in the components of a FMCW radar. Also described here is the algorithm used in calculating the phase error and application of the phase correction with triangle modulation. Known errors were calculated at certain …

    kennesaw Repository record for Implementation of Range Autofocus for SAR Radar Imaging (opens in a new tab)

  8. Subspace informed compressed sensing reconstruction techniques for diffusion tensor imaging

    … the use of strong gradient magnetic fields to dephase the signal of any protons undergoing diffusion, leading to a reduction in signal magnitude in that voxel. There is increasing use of iterative reconstruction algorithms of MRI data using the principles of compressed sensing (CS) that rely on …

    ubc Repository record for Subspace informed compressed sensing reconstruction techniques for diffusion tensor imaging (opens in a new tab) Download PDF for Subspace informed compressed sensing reconstruction techniques for diffusion tensor imaging (opens in a new tab)

  9. Metasurface-augmented gradient-index lenses for millimetre-wave applications

    … is established by analysing the electric field phases within a GRIN lens along with the phase shift in a single unit cell, using full-wave simulation tools available to researchers.<br/><br/>The research investigates two GRIN lenses: the 2D Luneburg lens antenna and the 2D Maxwell fisheye lens …

    qu-belfast Repository record for Metasurface-augmented gradient-index lenses for millimetre-wave applications (opens in a new tab) Download PDF for Metasurface-augmented gradient-index lenses for millimetre-wave applications (opens in a new tab)

  10. Hardware Approaches for Enabling Multi-Channel Multinuclear MRI/MRS

    … explored. This dissertation presents a hardware phase correction solution for receive-only frequency translation, addressing phase incoherence caused by different frequencies between transmit and receive. The proposed hardware utilizes passive phase detectors, a direct digital synthesizer (DDS), …

    tamu Repository record for Hardware Approaches for Enabling Multi-Channel Multinuclear MRI/MRS (opens in a new tab)

  11. Aberration Correction Methods for Transspinal Focused Ultrasound

    … and a spine-specific aperture, found that phase correction with ray acoustics reduced planar focal shifts relative to uncorrected focusing, but did not match a hydrophone-corrected gold standard. Off-target contributions through acoustic windows were hypothesized to contribute to large …

    toronto-retro Repository record for Aberration Correction Methods for Transspinal Focused Ultrasound (opens in a new tab)

  12. An Analysis of the Environment and Gas Content of Luminous Infrared Galaxies

    … populations, we conclude that ULIRGs might be a phase in the lives of AGNs and QSOs, but not all moderate-luminosity QSOs necessarily pass through a ULIRG phase. To study the interstellar medium properties, we observe HI and other spectral lines in 77 U/LIRGs with the Arecibo telescope. We detect …

    maryland Repository record for An Analysis of the Environment and Gas Content of Luminous Infrared Galaxies (opens in a new tab)

  13. The IRMA III control and communication system

    … submillimeter arrays as a method of phase correction. The IRMA III instrument employs a distributed, multi-tasking software control system permitting precise fine-grained control at remote locations over a low-bandwidth network connection. IRMA's software is divided among three …

    lethbridge Repository record for The IRMA III control and communication system (opens in a new tab)

  14. High-resolution diffusion imaging with DIFRAD-FSE (diffusion-weighted radial acquisition with fast spin echo) MRI

    … in either 2D or 3D Fourier space. Motion correction is accomplished via one of four correction techniques: phase correction, shift correction, a combination of the phase and shift correction, or magnitude. Images from a radial data set are reconstructed with filtered back projection …

    arizona-thes Repository record for High-resolution diffusion imaging with DIFRAD-FSE (diffusion-weighted radial acquisition with fast spin echo) MRI (opens in a new tab)

  15. Direct Water and Fat Determination in Two-Point Dixon Imaging

    … direct water and fat determination without phase correction, and we have quantified the reliability of this technique as a function of the echo times. The results may provide valuable guidance for selecting scan parameters to balance the objectives of optimizing fat-water identification, …

    rice Repository record for Direct Water and Fat Determination in Two-Point Dixon Imaging (opens in a new tab)

  16. Phased array excitations for efficient near-field wireless power transmission

    … in the near field requires that excitation correction methods be applied to the transmitter antenna. The emphasis of this thesis is a parametric study of two correction methods to focus the transmitter array beam to the receiver array. Quadratic-phase correction and complex-conjugate …

    nps Repository record for Phased array excitations for efficient near-field wireless power transmission (opens in a new tab)

  17. Time delay compensation in finite-order models of acoustic wave propagation in homogenous media

    … wave propagation and thus require an additional phase correction, besides parameter adjustments to fit experimental measurements. As a consequence, it is necessary to determine the time or phase delay of a finite-order model as a function of excitation frequency and model order. In this work a …

    missouri Repository record for Time delay compensation in finite-order models of acoustic wave propagation in homogenous media (opens in a new tab)

  18. Improving Seismic-to-well Ties

    … wavelet evolves with amplitude decay and minimum-phase dispersion. Stationary deconvolution estimates and eliminates a single wavelet from the nonstationary trace, resulting in large nonstationary amplitude and phase errors. Gabor deconvolution accurately estimates and eliminates the amplitude …

    calgary Repository record for Improving Seismic-to-well Ties (opens in a new tab)

  19. Design, Characterization, and Implementation of Optical Systems for Remote Sensing of the Atmosphere and Astrophysical Objects

    … is focused on the high precision optical phase correction for the photonic Local Oscillator (LO) designed for the Atacama Large Millimeter Array (ALMA). The phase instability in the original fiber optics design scheme is characterized and a novel, singlemode fiber-based interferometric …

    arizona-thes Repository record for Design, Characterization, and Implementation of Optical Systems for Remote Sensing of the Atmosphere and Astrophysical Objects (opens in a new tab)

  20. Artifact reduction in functional magnetic resonance imaging

    … caused by blood flow, variations in NMR signal phase, and patient motion. A new method of MR imaging called partial presaturation (PSAT) was developed that allows fMRI studies to be performed with reduced sensitivity to blood flow. The method is more effective than previous techniques for …

    manitoba Repository record for Artifact reduction in functional magnetic resonance imaging (opens in a new tab)

Page 1 of 4