Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 535 for “"phase-contrast"”.
-
New implementations of phase-contrast imaging
Phase-contrast imaging is a method of imaging widely used in biomedical research and applications. It is a label-free method that exploits intrinsic differences in the refractive index of different tissues to differentiate between biological structures under analysis. The basic principle of …
-
Motion tracking in phase-contrast microscopic images
… The proposed methods have been tested on the phase-contrast microscopic videos provided by Garvan Institute of Medical Research. Quantitative and qualitative analysis presented in this thesis show that employing temporal information for both cell segmentation and mitosis detection does improve …
-
Spectral Phase Contrast Imaging and Phase Retrieval
Phase-contrast X-ray imaging (PCI) can significantly improve the contrast of small and weakly-absorbing materials. This is because of the sensitivity of PCI measurements to changes in both the attenuation and phase of an X-ray wavefield due to interactions with matter. Yet, quantitative estimates …
-
Phase Contrast Imaging of Laser-Induced Microcavitation
… setup to image microcavitation develop with phase contrast microscopy. The goal of the numerical simulation is to accurately model the microcavitation process. The corresponding goal of the experimental setup is to identify additional features not visible in brightfield microscopy. The …
-
Phase contrast transmission electron microscopy using phase plates
… of cells and polymers often leads to poor image contrast and poor transfer of information with a spatial frequency lower than around 2 nm. In addition, the information contained in the phase of the specimen exit wave is often lost due to an inability to directly record phase changes. Electron …
-
Asymmetric Illumination X-ray Differential Phase Contrast Imaging
… we present a novel, low-cost approach to x-ray phase contrast imaging (XPCI). This method, which we term asymmetric illumination x-ray phase contrast imaging (AIXPCI), is compatible with a broadband tabletop x-ray source in a conventional laboratory setting and utilizes an angular filtration …
-
Advances in Magnetic Resonance Phase‐Contrast Velocity Mapping
Phase-contrast MRI is used to assess functional flow parameters of the cardiovascular system. Long scan times of three-dimensional flow encoded MRI in particular have, however, hampered the acceptance of the method in a clinical routine setting. Furthermore, concerns have recently been raised about …
-
Multiscale neuroimaging using synchrotron X-ray phase-contrast tomography
X-ray phase-contrast tomography (X-PCI-CT) is an emerging imaging technology in the field of biomedicine. This methodology represents an advancement compared to traditional absorption-based X-ray CT in that it can measure phase-shift-inducing X-ray refraction effects in addition to photon …
-
X-ray Phase Contrast Tomography : Setup and Scintillator Development
… on the micrometre scale. To improve the image contrast for small and low-density samples, it is possible to introduce a propagation distance between sample and detector to perform propagation-based phase contrast imaging (PB-PCI). This contrast mode relies on a sufficiently coherent …
-
Advances in Energy Sensitive X-ray Phase Contrast Measurements
… This approach proposes that rotating a steep phase gradient in a predetermined sinusoidal pattern will remove additional sources of noise and bias and isolate the influence of refraction. (2) A robust simulation of this energy sensitive refractometer. This simulation is used to initially …
-
Effectiveness of the Phase Contrast Microscope in Dental Patient Motivation
… was to examine the effectiveness of the phase contrast microscope when used as an adjunct to a patient education program in motivating individuals to improve oral hygiene habits. A convenience sample with randomized groups was utilized to select sixty-five subjects. Subjects attended five …
-
Characterizing single ventricle hemodynamics using phase contrast magnetic resonance imaging
… operation. Despite significant development of phase contrast magnetic resonance imaging (PC MRI) for in vivo flow measurements, it is not routinely applied in children with single ventricle congenital heart disease. Limited technologies available for post-processing of PC MRI data has prevented …
-
Haemodynamic Assessment of Coronary Flow with CFD and Phase-Contrast MRI
… dynamically scaled coronary phantom flow with phase-contrast magnetic resonance imaging (PC-MRI). A range of idealised and patient-specific coronary artery geometries, with and without stents, were generated based on a statistical shape database from computed tomography (CT) angiograms, and …
-
Development of X-ray phase-contrast imaging techniques for medical diagnostics
The X-Ray phase-contrast techniques are innovative imaging methods allowing overtaking the limitations of classic radiology. In addition to the differential X-ray absorption on which standard radiology relies, in phase-contrast imaging the contrast is given by the effects of the refraction of …
-
Joint Reconstruction for Single-Shot Edge Illumination Phase-Contrast Tomography (EIXPCT)
Edge illumination X-ray phase-contrast tomography (EIXPCT) is an emerging X-ray phasecontrast tomography technique for estimating the complex-valued X-ray refractive index distribution of an object with laboratory-based X-ray sources. Conventional image reconstruction approaches for EIXPCT require …
Page 1 of 27