Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 41 for “"phase-contrast MRI"”.

  1. Haemodynamic Assessment of Coronary Flow with CFD and Phase-Contrast MRI

    … dynamically scaled coronary phantom flow with phase-contrast magnetic resonance imaging (PC-MRI). A range of idealised and patient-specific coronary artery geometries, with and without stents, were generated based on a statistical shape database from computed tomography (CT) angiograms, and …

    auckland-ms Repository record for Haemodynamic Assessment of Coronary Flow with CFD and Phase-Contrast MRI (opens in a new tab)

  2. Flow and pressure measurement using phase-contrast MRI : experiments in stenotic phantom models.

    … these lesions are clinically significant. Phase-contrast MRI (PC-MRI) provides a powerful and non-invasive method to acquire spatially registered blood velocity. The velocity field, then, can be used to derive other clinically useful hemodynamic parameters, such as blood flow and blood …

    louisville Repository record for Flow and pressure measurement using phase-contrast MRI : experiments in stenotic phantom models. (opens in a new tab)

  3. 4D ultra-short TE (UTE) phase-contrast MRI for assessing stenotic flow and hemodynamics.

    Phase-contrast (PC) MRI is a non-invasive technique to assess cardiovascular blood flow. However, this technique is not accurate in the case of atherosclerotic disease and vascular and valvular stenosis due to intravoxel dephasing secondary to disturbed blood flow, flow recirculation, and …

    louisville Repository record for 4D ultra-short TE (UTE) phase-contrast MRI for assessing stenotic flow and hemodynamics. (opens in a new tab)

  4. Incorporating the Aortic Valve into Computational Fluid Dynamics Models using Phase-Contrast MRI and Valve Tracking

    … normal aortic valve. Magnetic resonance imaging (MRI) has been used clinically to assess aortic arch morphology and blood flow in these patients. These MRI data have been used in computational fluid dynamics (CFD) studies to investigate potential adverse hemodynamics in these patients, yet few …

    marquette Repository record for Incorporating the Aortic Valve into Computational Fluid Dynamics Models using Phase-Contrast MRI and Valve Tracking (opens in a new tab)

  5. An investigation of CSF dynamics and biochemical composition in normal pressure hydrocephalus utilizing the phase contrast MRI scanning

    … and simple magnetic resonance imaging (MRI) of the head are widely used clinically as part of the investigations, but these can not be relied upon completely. Cine Phase contrast MRI scanning is a more sophisticated technique of examining the flow of CSF through different regions of the …

    cent-lancashire Download PDF for An investigation of CSF dynamics and biochemical composition in normal pressure hydrocephalus utilizing the phase contrast MRI scanning (opens in a new tab)

  6. Real-time MRI of Moving Spins Using Undersampled Radial FLASH

    … when studied using magnetic resonance imaging (MRI). Moving spins define many functional characteristics of the human body such as diffusion, perfusion and blood flow. Quantitative MRI of moving spins can provide valuable information about the human physiology or of a technical system. In …

    wurz-thes Repository record for Real-time MRI of Moving Spins Using Undersampled Radial FLASH (opens in a new tab)

  7. Sparse Sampling of Velocity MRI

    <p>Standard MRI is used to image objects at rest. In addition to standard MRI images, which measure tissues at rest, Phase Contrast MRI can be used to quantify the motion of blood and tissue in the human body. The current method used in Phase Contrast MRI is time consuming. The development of new …

    mcmaster Repository record for Sparse Sampling of Velocity MRI (opens in a new tab)

  8. Fetal Blood Flow Mapping with Magnetic Resonance Imaging

    Phase contrast magnetic resonance imaging (MRI) has the potential to assess fetal blood flow. However, it faces challenges such as the small size of fetal vessels, the high fetal heart rate, uncontrolled fetal motion, limited methods to measure the fetal heart rate and the considerable complexity …

    toronto-retro Repository record for Fetal Blood Flow Mapping with Magnetic Resonance Imaging (opens in a new tab)

  9. Advances in Magnetic Resonance Phase‐Contrast Velocity Mapping

    Phase-contrast MRI is used to assess functional flow parameters of the cardiovascular system. Long scan times of three-dimensional flow encoded MRI in particular have, however, hampered the acceptance of the method in a clinical routine setting. Furthermore, concerns have recently been raised about …

    kings Repository record for Advances in Magnetic Resonance Phase‐Contrast Velocity Mapping (opens in a new tab)

  10. Cerebral blood flow and intracranial pulsatility in cerebral small vessel disease

    … might be an alternative mechanism. Pulse-gated phase-contrast MRI is an imaging technique that allows measuring of CBF contemporaneously with pulsatility in multiple vessels and cerebrospinal fluid (CSF) spaces. The overall aim of this thesis was to provide an overview of existing clinical …

    edinburgh Repository record for Cerebral blood flow and intracranial pulsatility in cerebral small vessel disease (opens in a new tab)

  11. Towards the development of biomarkers for traumatic spinal cord injury: quantitative clinical imaging in a pre-clinical model to assess intrathecal morphology and cerebrospinal fluid flow

    … (ultrasound and magnetic resonance imaging [MRI]) following thoracic contusion SCI in a domestic porcine model. The first study presented in this thesis used serial intraoperative ultrasounds within the first 24-hours post-SCI (n = 10) and showed that spinal cord swelling was either rapid or …

    adelaide Repository record for Towards the development of biomarkers for traumatic spinal cord injury: quantitative clinical imaging in a pre-clinical model to assess intrathecal morphology and cerebrospinal fluid flow (opens in a new tab)

  12. Measuring blood flow and pulsatility with MRI: optimisation, validation and application in cerebral small vessel disease

    … microvasculature. Magnetic resonance imaging (MRI) allows us to non-invasively measure blood flow and velocity using a technique called phase contrast-MRI – traditionally used with 2D slices across the vessel(s) of interest. An advanced form of phase-contrast MRI, known as 4D flow, has emerged …

    edinburgh Repository record for Measuring blood flow and pulsatility with MRI: optimisation, validation and application in cerebral small vessel disease (opens in a new tab)

  13. Improving patient-specific assessments of regional aortic mechanics via quantitative magnetic resonance imaging with early applications in patients at elevated risk for thoracic aortopathy

    … echoes (DENSE) magnetic resonance imaging (MRI) has been used previously to determine heterogeneous circumferential strain patterns in the aortas of healthy volunteers. Here, I introduce technical improvements to DENSE aortic analysis and early pilot application in patients at higher risk …

    vcu Repository record for Improving patient-specific assessments of regional aortic mechanics via quantitative magnetic resonance imaging with early applications in patients at elevated risk for thoracic aortopathy (opens in a new tab)

  14. Mri Methods For Imaging The Feto-Placental Vasculature And Blood

    Fetal magnetic resonance imaging (MRI) in recent times has become a well-established adjunct to ultrasound (US) in routine clinical prenatal care and diagnostics. The majority of fetal MRI is restricted to T2-weighted scans, where the diagnosis is based on the appearance of normal and abnormal …

    wayne-thes Repository record for Mri Methods For Imaging The Feto-Placental Vasculature And Blood (opens in a new tab)

  15. MODELING OF PATIENT-SPECIFIC PERIAORTIC MECHANICS AND PULMONARY ARTERY HEMODYNAMICS BASED ON PHASE-CONTRAST MAGNETIC RESONANCE IMAGING SEQUENCES.

    … risks and costs. Herein, three different phase contrast magnetic resonance imaging (MRI) modalities were implemented as input data, displacement encoding with stimulated echoes (DENSE MRI) applied, and time-resolved velocity encoding phase-contrast MRI, in 1D and 3D, applied to pulmonary …

    vcu Repository record for MODELING OF PATIENT-SPECIFIC PERIAORTIC MECHANICS AND PULMONARY ARTERY HEMODYNAMICS BASED ON PHASE-CONTRAST MAGNETIC RESONANCE IMAGING SEQUENCES. (opens in a new tab)

  16. A study of spatial encoding and decoding in MRI

    … the key feature) of Magnetic Resonance Imaging (MRI). Since the discovery that magnetic field gradients could be used to localize signal, researchers have sought methods to acquire higher quality images, with greater efficiency. This dissertation investigates three approaches for encoding and …

    ubc Repository record for A study of spatial encoding and decoding in MRI (opens in a new tab) Download PDF for A study of spatial encoding and decoding in MRI (opens in a new tab)

  17. Accelerating Multi‐Dimensional Magnetic Resonance Imaging of Blood Flow and Turbulence in the Cardiovascular System

    … to pathologies of the cardiovascular system. Phase‐contrast Magnetic Resonance Imaging (MRI) provides a non‐invasive technique for the assessment of time‐resolved blood velocity vector fields within arbitrary imaging volumes. Besides velocity vector field information, parameters related to …

    kings Repository record for Accelerating Multi‐Dimensional Magnetic Resonance Imaging of Blood Flow and Turbulence in the Cardiovascular System (opens in a new tab) Download PDF for Accelerating Multi‐Dimensional Magnetic Resonance Imaging of Blood Flow and Turbulence in the Cardiovascular System (opens in a new tab)

  18. Measurement of Cerebral Metabolism and Vascular Function with Magnetic Resonance Imaging

    … tomography (PET) or magnetic resonance imaging (MRI) involve special equipment and/or exogenous agents, and may not be suitable for routine clinical studies. To fill this gap, I developed a noninvasive method for quantifying whole brain CMRO2. This method uses the Fick principle of arterio-venous …

    utswmed Repository record for Measurement of Cerebral Metabolism and Vascular Function with Magnetic Resonance Imaging (opens in a new tab)

Page 1 of 3