Showing 1 to 20 of 201 for “"piezometers"”.
-
Characterizing Aquitard Properties from the response of Grouted Vibrating Wire Piezometers to Surface Loading
… response within grouted-in vibrating wire piezometers to changes in surface barometric pressure. The BRF facilitates determination of loading efficiency (λLE) which is a function of in situ compressibility. However, the mechanisms which control the characteristic shape of a BRF within a …
-
Using coefficient of consolidation to assess response time and reading accuracy of piezometers in grouted boreholes in fat clays
Reading accuracy of a piezometer in a fully grouted borehole has typically been assessed by comparing the hydraulic conductivity of the grout (K[subscript grout]) to that of the soil (K[subscript soil]). The field conditions of interest to this study represent the case of a relatively permeable …
-
Assessment of biogeochemical transformation of nitrate in shallow groundwater in the agricultural landscape : a thesis presented in partial fulfilment of the requirements for the degree of Master of Science in Soil Science at Massey University, Manawatu, New Zealand
… 7 sets of monthly groundwater observations at 17 piezometers from March to September 2018 to characterize the groundwater monthly chemical variations. The collected groundwater samples were analyzed for groundwater redox status, including dissolved oxygen (DO), oxidation-reduction potential, pH, …
-
Monitoring Hydrology in Created Wetland Systems with Clayey Soils
… array of manually monitored wells and piezometers were installed. The electronic arrays contained a U.S. Army Corps of Engineers (USACOE) standard monitoring well, as well as piezometers and tensiometers at three depths. The manually monitored well + piezometer arrays (3 per location; 9 …
-
Uma análise do comportamento das células de carga e dos piezômetros pneumáticos fabricados pela COPPE para utilização no metrô do Rio de Janeiro
… field, are examined: Load Cells and Hidraulic Piezometers. The Load Cells were utilized in the strutted diaphragm wall to measure the loads that were carried by the struts, while the Pneumatic Piezometers were utilized measurement of the pore-water pressure behind the walls and at the bottom …
-
Design and in situ testing of a piezometer system to measure earthquake -induced pore -pressure changes
… being tested and damaged or destroyed some piezometers being tested. This thesis describes the design and field-testing of a piezometer system that allows in situ testing of the screens on the piezometer, and in situ calibration of the transducer. An intergral part of this system is a signal …
-
Redesigning of soil landscape models within the Rangitikei district for the inclusion of groundwater information (e.g., nitrogen and phosphorus) : a thesis presented in partial fulfilment of the requirements for the degree of Master of Science in Earth Science at Massey University, Manawatu, New Zealand
… of each LRI component. The instillation of 6 piezometers across the study area at locations that intersected drainage zones with distinctive landform features and geologies, allowed for an overview of the drainage across the study area, with the aim to provide supportive evidence of the …
-
Small-scale variability of groundwater-lake interaction at Shingobee Lake, Minnesota
… shore and extending nine meters into the lake). Piezometers were installed at a depth of one half and one meter in nests at 70 locations in the rectangular study site. Water levels were collected from the piezometers and used to determine gradients. Temperature and conductance data of the water …
-
Análise de dados piezométricos de um aterro sobre argila mole com drenos verticais
The purpose of this dissertation is to analyse piezometers data from Trial Embankment II of IPR-DNER on Sarapui’s soft clay with vertical drains. Initially, the excess poro pressure data from installed Casagrande and Hydraulic piezometers of all the sections are analised and compared. Follows a …
-
Forest groundwater hydrology: implications for terrain stability in coastal British Columbia
… a landslide headscarp area with tensiometers and piezometers to characterize the groundwater regime over one year. Piezometers were designed and manufactured specifically for use in this project. Data collected from the study site indicate a highly variable distribution of storm-induced positive …
-
The hydrogeological and contaminant transport properties of fractured Leda clay in eastern Ontario.
… with the use of boreholes and test pits. Piezometers were installed using a conventional auger method and the double-Shelby method developed at the University of Waterloo. Hydrogeological aspects of the upper twelve metres were analyzed using water level fluctuations and variation …
-
Mechanisms and longevity of strain localization during dynamic recrystallization of olivine
… the consistency of existing stress-grain size piezometers that are used to estimate the strength of the lithosphere. Using quartz–feldspar- and olivine–orthopyroxene-bearing mylonites, which are common mineral pairs in crustal and mantle rocks, I quantify new piezometers for feldspar and …
-
Estimating groundwater inflow and age characteristics in an alluvial aquifer along the Little Wind River, Wyoming
… was sampled in the stream, shallow in-stream piezometers and nearby alluvial groundwater wells to determine the volume and spatial distribution of groundwater discharge to the river. Age tracers, CFC and SF6, sampled in the stream, shallow in-stream piezometers and in alluvial groundwater …
-
Estimating groundwater inflow and age characteristics in an alluvial aquifer along the Little Wind River, Wyoming
… was sampled in the stream, shallow in-stream piezometers and nearby alluvial groundwater wells to determine the volume and spatial distribution of groundwater discharge to the river. Age tracers, CFC and SF6, sampled in the stream, shallow in-stream piezometers and in alluvial groundwater …
-
Impact of Constructed Wetlands for Wastewater Treatment on Groundwater at Huron, South Dakota
… for all of the groundwater monitoring wells and piezometers and derive specific conclusions from the analysis of the results. Additionally, water quality parameters were examined for common ions in an effort to assess what, if any, changes are occurring with respect to groundwater quality …
-
Comportamento de uma massa coluvial
… pluviographs, water level meters, Casagrande piezometers and electrical piezometers, as well as the monitoring of deep horizontal drains (DHDs). Geotechnical profiles have been defined based on the results from rotary drilling and topographic and geophysical survey. The soil parameters were …
-
Advancing internal erosion monitoring using seismic methods in field and laboratory studies
… With the benefit of arrays of closely spaced piezometers, pore pressure trends indicated internal erosion near the initiation time. Temporally and spatially dense pore water pressure measurements detected two pore water pressure transitions characteristic to the development of internal …
-
Earth-fissure movements associated with fluctuations in ground-water levels near the Picacho mountains, south-central Arizona, 1980-84
… fluctuations were continuously monitored in four piezometers nested in two observation wells. The range of horizontal movement was 4.620 mm, and the range of water-level fluctuation in the nearest piezometer in the deeper alluvium was 9.05 m. The maximum annual opening of the fissure during the …
-
Relations between hydrogeology and soil characteristics near Deloraine, Manitoba
… To characterize the hydrogeology, 15 nests of piezometers were installed in the Quaternary and bedrock deposits. Hydraulic head data and samples of the groundwater were obtained from the piezometers. The hydraulic head data, chemistry of the groundwater and knowledge of the stratigraphy were …
Page 1 of 11