Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 87 for “"pipetting"”.
-
Pipetting Device for the Separation of Protein Complexes
The objective of this project is to develop an automated device used to spot protein samples on a hydrophobic membrane. We have developed two automated methods using a pneumatic tool to bring the pipette to its desired position relative to the hydrophobic membrane. They consist of ways of …
-
Development and Application of a Microprocessor-Controlled Multichannel Pipetting System for Clinical/analytical Chemistry
Made available in DSpace on 2014-12-13T20:10:11Z (GMT). No. of bitstreams: 1 7804006.pdf: 6181927 bytes, checksum: d60c2a7581b186b8848cf3cfc5d46960 (MD5) Previous issue date: 1977
-
Droplet Ejections During Wet Lab Operations Aboard Spacecraft
… of the bridge. When rupture occurs under typical pipetting conditions the dynamics governing the rupture almost always produce at a minimum a satellite droplet. When these droplets occur they are often too small and too fast to be observed by the human eye. In a terrestrial environment they are of …
-
Highly scalable combinatorial mixing of samples with target-specific primers for rapid pathogen detection on a centrifugal platform
… robots required to perform vast numbers of pipetting steps significantly hampers the proliferation of key enabling technologies into smaller laboratories. Centrifugal microfluidic devices have emerged as increasingly useful tools for biomedical applications and diagnostics and can be …
-
Persistence of Enteric Viruses on Surfaces under Varying Environmental Conditions
… (cell scraper, macrofoam swab, repeated pipetting) and 2 eluents (1×Phophaste buffered saline solution (PBS), 1×PBS+0.1%Tween80 (PBST; 1:1 v/v)). The repeated pipetting method with PBST eluent was selected for persistence studies though no significant differences were observed compared to …
-
The design and fabrication of a magnetically actuated microfluidic dispensing device
… for a novel dispensing device, targeted for pipetting precise volumes of fluid into integrated fluidic devices.</p> <p>A novel technique to displace fluid, in the nanolitre volume range, using a para-magnetic bead plug was proposed and subsequently demonstrated. Actuation of the dispensing …
-
Innovations in Sample Handling Automation to Increase Accessibility of Sample-Limited Proteomics
… It outlines our efforts to adapt a low-cost pipetting robot to emulate the sample preparation process outlined in nanoPOTS method for single-cell proteomics. Using this system, we compared the standard nanoPOTS sample preparation method with a simplified method for faster sample preparation. …
-
Examining peak height ratios in low template DNA samples with and without sampling using a single-tube extraction protocol
… believed to be due to: 1) pre-PCR sampling from pipetting and sample transferal of dilute samples prior to amplification resulting in unbalanced heterozygous allele templates in the amplification reaction, and 2) the kinetics of the PCR process where, when few target templates are available, …
-
Miniaturization of Proteomics Sample Preparation by Digital Microfluidics
… feasible. However, due to factors such as manual pipetting errors and the large volumes of reactants used, conventional proteomics protocols are not applicable for low-input proteomic sample processing. In nanoproteomics, sample preparation methods are tailored to the analysis of minute amounts of …
-
An assessment of pipette calibration stability using statistical process control charts
… simulations investigated multiple hypothetical pipetting scenarios concerning various levels of systematic bias. The simulations consistently corroborated the value of Shewhart charts to enforce better compliance between a pipette’s nominal and actual volume delivery, while the serial dilution …
-
A Software System for Automating Lab Experiments with Liquid-Handling Robots
… to handle experiments that involve complex pipetting, multi-day measurements and manipulations, and time-critical procedures. In Chapter 4, we present quality control experiments that characterize the pipetting performance of the robot; this is used for troubleshooting, error detection, and …
-
An evaluation of a bioassay method for thyroid stimulating hormone and its application to Citellus richardsoni
… error was not introduced by the method of pipetting aliquots of incubation medium in order to estimate I131 activity. Incubation times for uptake and release agree with those suggested by Bottari's group. While per cent uptake and absolute release of I131 were significantly related to the …
-
Evaluation of the effects of trehalose on the amplification of the 15 short tandem repeats loci of the AmpFℓSTR Identifiler Plus PCR Amplification Kit
… of DNA. The reason is that the propagation of pipetting error during the preparation of each batch could have contributed to the difference in the amount of DNA between each conditions which can be directly reflected in peak heights. Furthermore, unexpected discrepancy between the average peak …
-
Creating a virtual standard curve for quantitative PCR
… even when using the same samples, due to small pipetting differences or errors which can make sample reruns and verifying data difficult. Creating a virtual curve by using data from multiple serial dilutions would minimize or eliminate the variance between runs. This is accomplished by taking …
-
Comparing semi-automated microscopic sperm counting to DNA quantitation using qPCR to assess DNA quantities for forensic analysis
… including lack of reproducibility in semen pipetting, method-specific considerations, and human error. The differences in DNA quantities between the two methods were found to be statistically significant (p < 0.0001 for all except the 1:100 dilution from aliquot C where p < 0.01 and the …
-
Novel fabrication of flexible microelectrodes with macroporous platinum film using latex polystyrene sphere template
… bead template was deposited by simple pipetting of bead solution over gold contact openings and evaporating in ambient room setting. Pulsed-potentiostatic mode electrochemical deposition of platinum through the polystyrene bead template resulted in increase in effective surface area of …
-
Investigating the origin of stochastic effects in low-template DNA samples by developing a single-tube extraction protocol
… reason is that pre-PCR sampling error from pipetting and sample transfers results in an uneven number of allele copies in the sample prior to amplification. Thus, it may not be PCR chemistry alone that contributes to stochastic effects, but also sampling error, which creates unequal allele …
-
Automation of library preparation for next generation sequencing by centrifugal microfluidics
… The cumbersome protocols include numerous pipetting as well as thermal cycling steps and are prone to errors by human manipulation. Consequently, experienced staff is required for the implementation of these protocols. During the library preparation, amplified DNA products need to be …
-
Optimisation of ExoCounter technology for use in cerebrospinal fluid and investigation of placenta-derived exosomes within cerebrospinal fluid
… on intact exosome membranes. The impact of human/pipetting error and human anti-mouse antibodies was assessed, with no evidence found of interference by either factor.
Page 1 of 5