Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 15 of 15 for “"planar dose"”

  1. A dosimetric study of a heterogeneous phantom for lung stereotactic body radiation therapy comparing Monte Carlo and pencil beam calculations to dose distributions measured with a 2-d diode array

    … (PB) calculations are compared to their measured planar dose distributions using a 2-D diode array for lung Stereotactic Body Radiation Therapy (SBRT). The planar dose distributions were studied for two different phantom types: an in-house heterogeneous phantom and a homogeneous phantom. The …

    fau Repository record for A dosimetric study of a heterogeneous phantom for lung stereotactic body radiation therapy comparing Monte Carlo and pencil beam calculations to dose distributions measured with a 2-d diode array (opens in a new tab)

  2. The Use of an On-Board MV Imager for Plan Verification of Intensity Modulated Radiation Therapy and Volumetrically Modulated Arc Therapy.

    … be used for tumor localization but for recording dose distributions as well. Several advantages make portal imagers attractive options for this purpose. Very high spatial resolution allows for better verification of small field plans than may be possible with commercially available devices. …

    ohiolink Repository record for The Use of an On-Board MV Imager for Plan Verification of Intensity Modulated Radiation Therapy and Volumetrically Modulated Arc Therapy. (opens in a new tab)

  3. A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices

    … an Electronic Portal Imaging Device (EPID) for dose verification. However, EPIDs have limitations stemming from the non-uniform backscatter due to the support-arm as well as from scatter, glare, and an increased sensitivity to low-energy photons. None of these effects is typically accounted for …

    mcmaster Repository record for A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices (opens in a new tab)

  4. Development and implementation of quality-assurance standards for external beam intensity modulated radiation therapy

    … Kodak X-Omat V (XV) film and Kodak Extended Dose Range (EDR2) filmwere used. Three IMRT plans (one prostate, one head & neck and one brain) were validated.The plans were transferred from the patient geometry to a 30 cm x 30 cm x 20 cm solid waterphantom. The ionization chamber was calibrated …

    ohiolink Repository record for Development and implementation of quality-assurance standards for external beam intensity modulated radiation therapy (opens in a new tab)

  5. IMRT Plan Delivery Verification Utilizing a Spiral Phantom with Radiochromic Film Dosimetry

    … various IMRT treatment plans comparing predicted planar fluence dose and measured dose using radiochromic film. A solid water cylindrical IMRT phantom manufactured by GAMMEX which has been machined creating a spiral cavity for placement of radiochromic film (GAFCHROMIC® EBT2) was employed for IMRT …

    ohiolink Repository record for IMRT Plan Delivery Verification Utilizing a Spiral Phantom with Radiochromic Film Dosimetry (opens in a new tab)

  6. Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator

    … irradiator. To accomplish this, the absolute dose calibration of the irradiator performed in accordance with the recommendations of AAPM TG-61 protocol. Both in-air and in-water calibrations were performed at a 30.5 cm source-to-surface distance (SSD) for the reference applicator 40x40 mm2 …

    utswmed Repository record for Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator (opens in a new tab)

  7. Development of an electron beam irradiation design for use in the treatment of municipal biosolids and wastewater effluent

    … dual electron-beam sources were modeled as planar surface sources above and below a stainless steel delivery trough containing either effluent water or one of two biosolids material compositions. A dose deposition analysis was performed to assess both the planar dose distribution and 25 …

    tamu Repository record for Development of an electron beam irradiation design for use in the treatment of municipal biosolids and wastewater effluent (opens in a new tab)

  8. Delivery and verification of intensity-modulated X-ray beams in radiotherapy

    In modern radiotherapy, 3D conformal dose distributions are achieved using several beam ports each having pre-calculated planar distributions of photon beam intensity. The intensity matrix for a given beam port is generated by independent motion of the leaves of a multileaf collimator (MLC). In …

    mcgill Repository record for Delivery and verification of intensity-modulated X-ray beams in radiotherapy (opens in a new tab)

  9. Development of a portal dose image prediction algorithm for arbitrary detector systems

    … the accurate calculation of a predicted portal dose image, including both primary and scatter dose components emerging from the patient. This thesis presents the development of a two step model that predicts dose deposition in arbitrary portal image detectors. The algorithm requires patient …

    manitoba Repository record for Development of a portal dose image prediction algorithm for arbitrary detector systems (opens in a new tab)

  10. Intensity Modulated Bolus Electron Conformal Therapy (IM-BECT): Methods for Quality Assurance of PRIME Intensity Modulators and Evaluation of Planned IM-BECT Dose Distributions

    … conformal therapy (IM-BECT) shapes homogeneous dose distributions to superficial, irregularly-shaped target volumes, avoiding nearby critical structures. This dissertation provides research useful for translating IM-BECT to the radiotherapy clinic by: (1) developing and testing a factory quality …

    lsu-thes Repository record for Intensity Modulated Bolus Electron Conformal Therapy (IM-BECT): Methods for Quality Assurance of PRIME Intensity Modulators and Evaluation of Planned IM-BECT Dose Distributions (opens in a new tab)

  11. A Dosimetric Evaluation of Obliquity and Irregular Surfaces as Addressed by a Commercial Electron Monte Carlo Dose Calculation Algorithm

    … is applying an obliquity factor – scaling the dose by a ratio measured for a given angle of oblique incidence. Alternatively, computerized treatment planning systems have been developed to accurately calculate the changes in side scatter due to obliquity. RayStation’s electron Monte Carlo (MC) …

    ohiolink Repository record for A Dosimetric Evaluation of Obliquity and Irregular Surfaces as Addressed by a Commercial Electron Monte Carlo Dose Calculation Algorithm (opens in a new tab)

  12. Quantitative Analysis of the Head Scatter and Jaw Transmission Correction Factor for Commissioning of Enhanced Dynamic Wedge Fields Using a MapCHECK 2 Diode Array

    … planning requires independent verification of dose to be delivered to a patient through ¿¿¿¿¿¿¿second check¿¿¿¿¿¿¿ calculations for simple plans as well as planar dose fluence measurements for more complex treatments, such as intensity modulated radiation treatments (IMRT). Discrepancies …

    ohiolink Repository record for Quantitative Analysis of the Head Scatter and Jaw Transmission Correction Factor for Commissioning of Enhanced Dynamic Wedge Fields Using a MapCHECK 2 Diode Array (opens in a new tab)

  13. Quantitative Assessment of Radiation Dosimetry from a MammoSite balloon, FSD Applicator and a Newly Designed HDR Applicator for Treatment of GYN Cancers Using Monte Carlo Simulations

    … leading to potential inaccuracies in dose distributions. Previous publications either have studied only a planar dose perturbation along the bisector of the source or have paid little attention to the anisotropy effect of the system. In this study, we investigated the …

    ohiolink Repository record for Quantitative Assessment of Radiation Dosimetry from a MammoSite balloon, FSD Applicator and a Newly Designed HDR Applicator for Treatment of GYN Cancers Using Monte Carlo Simulations (opens in a new tab)

  14. Applications of cone beam computed tomography in radiotherapy treatment planning.

    … (LINACs); these units are capable of 2D planar imaging, fluoroscopy and 3D Cone Beam Computed Tomography (CBCT) imaging. With CBCT imaging, the treatment plan can be modified based on patient’s anatomy just before the treatment session. This method of Adaptive Radiotherapy (ART) helps in …

    adelaide Repository record for Applications of cone beam computed tomography in radiotherapy treatment planning. (opens in a new tab)

  15. Clinical Applications Of Advanced Rotational Radiation Therapy

    … and its applications in helical tomotherapy dose delivery. We explore the limits of the system by applying it to challenging clinical cases of total marrow irradiation (TMI) and stereotactic radiosurgery (SRS). We also analyze the feasibility of alternative fractionation schemes for total …

    wayne-thes Repository record for Clinical Applications Of Advanced Rotational Radiation Therapy (opens in a new tab)