Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 10 of 10 for “"plaster model"”.
-
The evaluation of the reproducibility of mock surgery using plaster model and lateral cephalometric radiograph in sagittal split ramus osteotomy
… cephalometric radiograph and mock surgery using plaster model, surgical plan is established. After the surgery, the outcome of surgery is determined by analyzing the lateral cephalometric radiograph. In this study, by conducting the anterior-posterior comparison and analysis between preoperative …
-
The torsional analysis of beams of arbitrary cross-section with non-linear stress-strain properties
… from pure torsion tests on five unreinforced plaster model beams: three circular, one rectangular, and one T-shaped in cross-section. Results are also presented on a second series of twenty-nine qualitative tests made on plaster model T-beams reinforced with small gage wire to determine the …
-
Avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática
… study was to evaluate the accuracy of digital models generated by two scanning techniques (intraoral scanner - Itero 5d Element® - and desktop scanner -Straumann ®) of an experimental model of the upper arch (Nacional Ossos ®) made of polyurethane and the plaster model obtained from this arch. …
-
A Comparison of Two Three-Dimensional Computer-Generated Orthodontic Models with Conventional Plaster Models
… toothrelated measurements occurring in digital models associated with OrthoCAD™ and eModel™, when compared with a traditional plaster model control. This study was also done to examine the accuracy of dental models that are poured immediately when compared with plaster models that are created …
-
Analysis of a hyperbolic paraboloid
… results of displacements of a thin shell plaster model without edge beams and supported along two opposite edges. The model tested was 36" X 36" X 1/8" thick. The analysis is based on the Shallow Shell Theory and represents a combination of known techniques. In general good agreement was …
-
In-vitro Study Investigating the Validity and Reliability of a New Software for Digital Scoring of the American Board of Orthodontics Objective Grading System
… Grading System <br/>(ABO OGS) by using digital models to replace the conventional method (gold standard) of using plaster models and a hand ABO gauge. The secondary aims of the study are to assess the level of agreement between orthodontists and non-orthodontists’ ABO OGS scores using the …
-
Influence of Stainless Steel Orthodontic Brackets on Magnetic Resonance Imaging
… of the maxillary and mandibular arches. Three plaster model sets were poured from each impression, two model sets had stainless steel brackets incorporated into essix trays and the remaining model was the control. The two stainless steel brackets used in this study were: 17-4 (bracket / base) …
-
Arboreal Calling Behaviour Across the Range of the Spring Peeper: Potential Consequences and Benefits
… loss, I performed a desiccation experiment using plaster model frogs. Model frogs at high perches lose water at a markedly faster rate than those on the ground, suggesting an increased risk of desiccation for arboreal individuals. Arboreal calling behaviour may therefore be partially governed by a …
-
Genauigkeit der Rekonstruktion des approximalen Kontaktpunktes bei konventionellen Set-up-Modellen
Set-up models are an important tool for diagnostics and therapy planning in today's dentistry and especially in orthodontics. Set-up models can be manufactured using a classical plaster model or digitally using a computer. Since the set-ups are used for model measurements, they should accurately …
-
Three-dimensional breast assessment by multiple stereophotogrammetry after breast reconstruction with latissimus dorsi flap
… A validation study was conducted. Nine plaster models were investigated and their volume determined by 3D stereophotogrammetry and water displacement method. Water displacement was considered to be the gold standard for comparison. The plaster models were specially made in order to …