Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"plate fixation"”.

  1. Optimisation of locking plate fixation methods for periprosthetic fractures

    … and an unstable prosthesis. Failure of locking plate fixation of fractures around the tip of a stable prosthesis (Vancouver type B1) have been reported clinically, suggesting that further investigation into their treatment is needed. This study developed a computational periprosthetic fracture …

    whiterose Download PDF for Optimisation of locking plate fixation methods for periprosthetic fractures (opens in a new tab)

  2. An Investigation into the Plate Fixation for Periprosthetic Femoral Fractures

    … of severe complications after the standard plate-screw fixation. To seek biomechanically sound fixations for the Vancouver type B1 fracture, this dissertation developed a combined modeling and testing framework to investigate the efficacy of fixation for a Vancouver type B1 fracture using …

    denver Repository record for An Investigation into the Plate Fixation for Periprosthetic Femoral Fractures (opens in a new tab)

  3. A Biomechanical Comparison of 3.5 Locking Compression Plate Fixation to 3.5 Limited Contact Dynamic Compression Plate Fixation in a Canine Cadaveric Distal Humeral Metaphyseal Gap Model

    … properties of 3.5 locking compression plate (LCP) fixation to 3.5 limited contact dynamic compression plate (LC-DCP) fixation in a canine cadaveric, distal humeral metaphyseal gap model in static axial compression and cyclic axial compression and torsion. Study Design- Biomechanical in …

    vt Repository record for A Biomechanical Comparison of 3.5 Locking Compression Plate Fixation to 3.5 Limited Contact Dynamic Compression Plate Fixation in a Canine Cadaveric Distal Humeral Metaphyseal Gap Model (opens in a new tab)

  4. Screw fixation of ACPHT acetabular fractures offers sufficient biomechanical stability when compared to standard buttress plate fixation

    … Geriatric acetabular fractures require fixation with sufficient primary stability to allow for immediate full-weight bearing. Minimally-invasive procedures would be desirable in order to keep perioperative morbidity low. The purpose of this study was to compare the biomechanical strength …

    zurich Repository record for Screw fixation of ACPHT acetabular fractures offers sufficient biomechanical stability when compared to standard buttress plate fixation (opens in a new tab) Restricted access

  5. Biomechanical Comparison of Wire Circlage and Rigid Plate Fixation for Median Sternotomy Closure in Human Cadaver Specimens

    … if mediastinitis supervenes. A secure and rigid fixation of surgically divided sternum is critical to avoid healing complications. The purpose of this study was to compare the yield load, construct stiffness, ultimate load, displacement at ultimate load, and post-yield behavior of three …

    calpoly Repository record for Biomechanical Comparison of Wire Circlage and Rigid Plate Fixation for Median Sternotomy Closure in Human Cadaver Specimens (opens in a new tab)

  6. Ιntramedullary nailing versus plate fixation for the treatment of proximal tibia extra-articular fractures, a meta-analysis

    Εισαγωγή: Η επίπτωση των εξωαρθρικών καταγμάτων της εγγύς κνήμης είναι αρκετά συχνή στον γενικό πληθυσμό και αντιστοιχεί περίπου στο 5-11% όλων των καταγμάτων της κνήμης. Η βέλτιστη μέθοδος αντιμετώπισης αυτών των καταγμάτων παραμένει αμφιλεγόμενη και μέχρι σήμερα δεν υπάρχει ευρεία συναίνεση …

    athens Repository record for Ιntramedullary nailing versus plate fixation for the treatment of proximal tibia extra-articular fractures, a meta-analysis (opens in a new tab)

  7. Comparison of patient-specific fixation devices and -materials in one segmental mandibular reconstruction using a finite element analysis

    … years, patient-specific titanium reconstruction plates are increasingly used since these pre-planned and anatomically customized plates simplify and shorten the surgery. However, the large reconstruction plates further increase the rates of osseous non-union. Therefore, alternative fixation …

    fu-berlin Repository record for Comparison of patient-specific fixation devices and -materials in one segmental mandibular reconstruction using a finite element analysis (opens in a new tab)

  8. Translational Models for Advancement of Regenerative Medicine and Tissue Engineering

    … tibial defect stabilized using single locking plate fixation. First, the biomechanical stability of the model was evaluated in vivo using plantar-pressure analysis of gait. Then, the surgical technique was refined through a retrospective analysis of the effects of plate length and position on …

    utk-theses Repository record for Translational Models for Advancement of Regenerative Medicine and Tissue Engineering (opens in a new tab)

  9. Locking plates for distal femur fractures does an increased working length improve healing?

    Distal femur locking plates have become a very popular means of internal fixation because of their ability to provide stable distal periarticular fixation. In spite of this enthusiasm however several studies have reported significant problems with healing. In the distal femur it is recognized that …

    cape-town Repository record for Locking plates for distal femur fractures does an increased working length improve healing? (opens in a new tab)

  10. Development of functional biocomposite compression bone plates

    Bone plates are used as one of the fixation methods to restore damaged bones in orthopaedic surgery. Conventional bone plates are mainly made of stainless-steel. However, high stiff stainless-steel plates induce bone absorption and occasionally a plated bone suffers osteoporosis. Hence, it is …

    nus Repository record for Development of functional biocomposite compression bone plates (opens in a new tab) Download file for Development of functional biocomposite compression bone plates (opens in a new tab)

  11. Design and Testing of a Piezoelectric Intramedullary Nail

    … common are: dynamization, reamed nailing after plate, exchange reamed nailing, augmentative plate fixation, and plate fixation. The current non-union treatments presented all aim to provide a fix to non-union but fail to address the preventative issue of non-union itself. It would be …

    ku Repository record for Design and Testing of a Piezoelectric Intramedullary Nail (opens in a new tab)

  12. Nonunion of the clavicle: novel use of clinical recovery and ultrasound to improve our ability to predict fracture healing

    … recent widespread increase in the use of acute plate fixation for displaced fractures is justified on current evidence. It is unknown whether the early accurate prediction of fractures at high risk of nonunion is advantageous. Currently the perceived risk of nonunion is largely based on factors …

    edinburgh Repository record for Nonunion of the clavicle: novel use of clinical recovery and ultrasound to improve our ability to predict fracture healing (opens in a new tab)

  13. Hydrogel-based co-delivery of lysostaphin and rifampin eliminates a chronic infection and promotes healing of bone defects

    … fracture model, both with intramedullary pin fixation and plate fixation hardware, as well as in methicillin-susceptible and methicillin-resistant strains of S. aureus. Mice receiving the hydrogel containing lysostaphin and local antibiotics also exhibited a more robust callus and bone …

    gatech Repository record for Hydrogel-based co-delivery of lysostaphin and rifampin eliminates a chronic infection and promotes healing of bone defects (opens in a new tab)

  14. Surgical management of acromioclavicular joint dislocations /

    … The treatment options are divided into elastic fixation and rigid fixation. The objective of this work was to review the different surgical treatments, their efficacy, complications and to compare different approaches of the treatment of dislocation of the acromioclavicular joint. In the end a …

    vilnius Repository record for Surgical management of acromioclavicular joint dislocations / (opens in a new tab)

  15. Proximal forearm fractures: epidemiology, functional results and predictors of outcome

    … out to compare 1) tension band wire (TBW) versus plate fixation in younger patients (<75 years) and 2) operative versus non-operative management in elderly patients (≥75 years). The primary outcome measure for these studies was the upper limb specific patient reported Disabilities of the Arm, …

    edinburgh Repository record for Proximal forearm fractures: epidemiology, functional results and predictors of outcome (opens in a new tab)

  16. A biomechanical analysis of three humeral fracture fixation systems

    <p>Often, humeral fractures requiring internal fixation can be a challenging orthopaedic procedure. Each method of treatment possesses clinical and biomechanical advantages and disadvantages. Rigid plate fixation is highly successful in treating a large variety of long bone fractures. Nevertheless, …

    njit Repository record for A biomechanical analysis of three humeral fracture fixation systems (opens in a new tab)

  17. Treatment of distal radius fractures with volar locking distal radius plates

    … options are open reduction and internal fixation or closed reduction and fixation with K-wires and/or an external fixator or cast. Until the late 1990s, open reduction and plate fixation was not a popular treatment option as plates inserted from the dorsal side frequently caused soft …

    jamescook Download PDF for Treatment of distal radius fractures with volar locking distal radius plates (opens in a new tab)

  18. Die palmare Rahmenplatte zur Versorgung instabiler distaler Radiusfrakturen: Behandlungsergebnisse nach operativer Versorgung mit der Aptus 2,5 mm Rahmenplatte – Versorgungszeitraum 2009 bis 2011 -

    Ziel/Hintergrund: Die Behandlung der distalen Radiusfraktur machte mit der Zeit eine zunehmende Entwicklung, sodass heute eine Vielzahl von verschiedenen Behandlungsverfahren beschrieben wurden. Dabei befasst sich die vorliegende retrospektive Studie vor allem mit der objektiven, subjektiven, …

    wurz-thes Repository record for Die palmare Rahmenplatte zur Versorgung instabiler distaler Radiusfrakturen: Behandlungsergebnisse nach operativer Versorgung mit der Aptus 2,5 mm Rahmenplatte – Versorgungszeitraum 2009 bis 2011 - (opens in a new tab)

  19. Ergebnisse nach operativer Versorgung von distalen Radiusfrakturen mit winkelstabiler Plattenosteosynthese

    In der vorliegenden Dissertationsarbeit werden die postoperativen Ergebnisse nach Osteosynthese der distalen Radiusfraktur mit der winkelstabilen unidirektionalen 3,5-er Platte der Firma Synthes mit den Ergebnissen nach Osteosynthese mit der multidirektionalen Platte der Firma Litos untereinander …

    fu-berlin Repository record for Ergebnisse nach operativer Versorgung von distalen Radiusfrakturen mit winkelstabiler Plattenosteosynthese (opens in a new tab)

  20. Kniegelenknahe Osteotomie mit Plattenfixateur - Ergebnisse und prognostische Faktoren

    Mit Hilfe der vorliegenden Arbeit wurde eine retrospektive, standardisierte Auswertung der Operationstechnik von kniegelenknahen Osteotomien im König-Ludwig-Haus erreicht. Seit 2006 wird dieser Eingriff erfolgreich durchgeführt, was durch sehr gute Patientenzufriedenheitswerte belegt wird. Im hier …

    wurz-thes Repository record for Kniegelenknahe Osteotomie mit Plattenfixateur - Ergebnisse und prognostische Faktoren (opens in a new tab)

Page 1 of 2