Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 47 for “"plethysmograph"”.

  1. Acoustic plethysmograph for measuring pulmonary function in mice

    The traditional whole body plethysmograph (WBP) relies on pressure changes induced by a freely respiring animal inside a chamber. This pressure is a combination of a thermo-hygrometric effect (proportional to tidal volume) and a gas compression effect (related to lung mechanics). In order to …

    wvu Repository record for Acoustic plethysmograph for measuring pulmonary function in mice (opens in a new tab)

  2. The reliability and validity of three new measures of male sexual preferences.

    The penile plethysmograph is currently accepted as the most reliable and valid measure of male sexual arousal and male sexual preferences. Several researchers, however, have begun to experiment with newer, less intrusive, measures such as Choice Reaction Time (CRT; Wright and Adams, 1999; 1995), …

    nodak Repository record for The reliability and validity of three new measures of male sexual preferences. (opens in a new tab)

  3. AN EVALUATION OF THE LEVEL OF SKILL REQUIRED OF OPERATORS OF A COMPUTER-ASSISTED RADIOLOGIC TOTAL LUNG CAPACITY MEASUREMENT SYSTEM (RELIABILITY, VALIDITY).

    … the TLC for that patient, obtained from a body plethysmograph. Only small differences in the group correlation coefficients were observed. A liberal test of these differences indicated they were not statistically significant. Additionally, two experience level by film sets ANOVAs were performed …

    arizona-thes Repository record for AN EVALUATION OF THE LEVEL OF SKILL REQUIRED OF OPERATORS OF A COMPUTER-ASSISTED RADIOLOGIC TOTAL LUNG CAPACITY MEASUREMENT SYSTEM (RELIABILITY, VALIDITY). (opens in a new tab)

  4. The use of impedance plethysmography to predict the onset of blood flow beneath a tourniquet cuff

    … was measured with a specially designed impedance plethysmograph. The electrode configurations used with the plethysmograph were evaluated with a computer model of the limb. A relationship was found between the impedance of the underlying tissue and the cuff pressure relative to the occlusion …

    ubc Repository record for The use of impedance plethysmography to predict the onset of blood flow beneath a tourniquet cuff (opens in a new tab) Download PDF for The use of impedance plethysmography to predict the onset of blood flow beneath a tourniquet cuff (opens in a new tab)

  5. Η ΑΕΡΟΠΛΗΘΥΣΜΟΓΡΑΦΙΑ ΣΤΟΝ ΕΛΕΓΧΟ ΤΗΣ ΑΙΜΟΔΥΝΑΜΙΚΗΣ ΤΗΣ ΦΛΕΒΙΚΗΣ ΝΟΣΟΥ

    AN AIR-PLETHYSMOGRAPH HAS BEEN DESIGNED IN ORDER TO MEASURE THE VENOUS VOLUMER OF THE LEG DURING CHANGE IN POSTURE AND EXERCISE WE MEASURED THE FUNCTIONAL VENOUS VOLUME, THE VENOUS FILLING TIME ON STANDING UP FROM SEPINE AND THE EXPELLEDAND RESIDUAL VOLUME DURING CALF MUSCLE CONSTRUCTION(S), IN 20 …

    greece Repository record for Η ΑΕΡΟΠΛΗΘΥΣΜΟΓΡΑΦΙΑ ΣΤΟΝ ΕΛΕΓΧΟ ΤΗΣ ΑΙΜΟΔΥΝΑΜΙΚΗΣ ΤΗΣ ΦΛΕΒΙΚΗΣ ΝΟΣΟΥ (opens in a new tab)

  6. Dispersion of Signal Averaged Pulsatile Blood Flow Waveforms Due to a Variable Heart Rate

    … are averaged in this thesis: photo-electric plethysmograph, doppler flowmeter, NMR blood flowmeter, electrocardiograph, and a pump system simulating blood flow on the extracorporeal electromagnetic flowmeter. Since these signals depend on the heart rate and the heart rate of a healthy …

    marquette Repository record for Dispersion of Signal Averaged Pulsatile Blood Flow Waveforms Due to a Variable Heart Rate (opens in a new tab)

  7. The Effects of Dehydration on Body Composition

    Since the mid 1990' s, air-displacement plethysmograph (ADP) has been researched and proposed to be an accurate, comfortable, and accessible method of body composition analysis. It continues to be compared to hydrostatic weighing (HW), the anthropometric "gold standard" for validity and …

    sdstate Repository record for The Effects of Dehydration on Body Composition (opens in a new tab)

  8. Emotional Congruity at Encoding and Retrieval as Internal Contextual Cues for Long-Term Memory

    … Manikin; physiological data (GSR, plethysmograph, respiration) were collected but not analyzed. Three hypotheses were tested: (1) congruent emotional states improve recall, (2) memory follows an inverted-U pattern with arousal, and (3) congruence benefits are stronger for fear. …

    york Repository record for Emotional Congruity at Encoding and Retrieval as Internal Contextual Cues for Long-Term Memory (opens in a new tab)

  9. In-vivo αξιολόγηση της άμεσης αποτελεσματικότητας μιας καινοτόμου τεχνολογίας αποκατάστασης της στυτικής δυσλειτουργίας μετά από ριζική προστατεκτομή

    … change of penile tumescence and (ii) by a penile plethysmograph system.The Main Outcome Measure was defined as theAbility and success rate of evoking penile response which were measured by applyingelectrical stimulation using the developed electrode array. Electrical stimulation produced immediate …

    greece Repository record for In-vivo αξιολόγηση της άμεσης αποτελεσματικότητας μιας καινοτόμου τεχνολογίας αποκατάστασης της στυτικής δυσλειτουργίας μετά από ριζική προστατεκτομή (opens in a new tab)

  10. Acute hemodynamic responses to yoga exercise

    … resistance were measured using a finger plethysmograph during the yoga routine. Baseline measures of trunk flexibility (sit-and-reach scores and inclinometer measurements) and arterial stiffness (carotid-femoral pulse wave velocity) were also compared. Yoga postures elicited significant …

    texas Repository record for Acute hemodynamic responses to yoga exercise (opens in a new tab)

  11. Effects of Methylxanthines on Newborn Rat Respiration

    … 7-day-old rats using a volume displacement body plethysmograph. Measurements were made before and at 5 minute intervals after subcutaneous (s.c.) injection of drug. Theophylline (1,3-diMX, 10-40 mg/kg) increased minute ventilation (VE) in a dose-related mannor by as much as 45% over baseline. …

    eiu Repository record for Effects of Methylxanthines on Newborn Rat Respiration (opens in a new tab)

  12. Self control of penile tumescence

    … and feedback training by means of a penile plethysmograph. Two dependent measures were recorded as deviations in millimeters from a pre-experimental baseline flaccidity measure, the first being peak erection during the whole session and the second being tumescence level attained at the end …

    uvic Repository record for Self control of penile tumescence (opens in a new tab)

  13. Evaluation of Accelerated Plethysmography as a Measure of Health and Fitness

    Plethysmography is a technique used for measuring alterations in the volume of organs or limbs. Japanese researchers have developed a relatively new application of plethysmography (accelerated plethysmography) that uses information from the pulse wave measured at the fingertip to make inferences …

    portland-state Repository record for Evaluation of Accelerated Plethysmography as a Measure of Health and Fitness (opens in a new tab)

  14. Contactless extraction of respiratory rate from depth and thermal sensors

    … rate such as Pneumograph, Capnograph, Photo-plethysmograph (PPG), Respiratory inductance plethysmography (RIP), involve sensors that are in contact with the patient. However, we have a few scenarios such as in hospitals and senior retirement communities where we would like to non-invasively …

    missouri Repository record for Contactless extraction of respiratory rate from depth and thermal sensors (opens in a new tab)

Page 1 of 3