Προβλεπόμενες (φυσιολογικές) τιμές της σπιρομέτρησης και της καμπύλης ροής/όγκου για τις ηλικίες 7 έως 15 ετών του ελληνικού πληθυσμού
… examined standing and with bare feet. We used a pneumotachograph connected with an X/Y recorder, type lam-15 Fucunda. The FVC, FEV₁, FEV₁%/FVC. MMFR, PEF, MEF₇₅, MEF₅₀, MEF₂₅, tests were computed manually from the hard copy of the X/Y recorder by the author. The FVC was computed from the …
-
Επίδραση της μέσης στερνοτομής στην θωρακοπνεμονική διατασιμότητα: αξιολόγηση μιας νέας απλής μεθόδου μέτρησής της
… with the NCI technique were more accurate pneumotachograph measurements. The pneumotachograph’s error increased as resistances increased and compliance decreased. Concordance analysis between the two techniques in ICU patients showed a satisfactory agreement, a similar reproducibility and …
-
Monitoring heart and lung function using in-line laserspectroscopy
… Respiratory flow is measured using a custom pneumotachograph. The highly-accurate respiratory profiles recorded by this device during a nitrogen washout procedure are fit to a computational model of lung to provide estimates of lung inhomogeneity. This thesis presents the first applications …
-
Pilot studies to develop and evaluate a muscle strengthening programme to reduce the risk of aspiration and improve outcome in stroke patients
… detectable difference was ≈7%. A calibrated pneumotachograph was found most appropriate for cough flow assessments, due to inaccuracy of portable flow meters (Bland-Altman 95% limits of agreement spanning ≈150 L/min). Automated cough frequency measurements (Leicester Cough Monitor) showed …
-
Υπερηχογραφική μελέτη του διαφράγματος σε υγιείς εθελοντές σε συνθήκες ήρεμης αναπνοής, αυξημένων εισπνευστικών αντιστάσεων και ελαττωμένης θωρακικής ευενδοτότητας
… nose clip and connection of the subjects to the pneumotachograph of the indirect calorimetry machine through a mouth piece. In phase III, the participants were assessed while subjected to inspiratory resistive loading of 50 cm H2O/lit/sec and in phase IV while breathing under conditions …
-
The Effects of Theophylline and 8-Cyclopentyltheophylline on the Respiratory Response to Carbon Dioxide in Neonatal Rats
… that was connected by plastic tubing to a pneumotachograph to measure the rat's respiration. A control period of normal breathing for 5 minutes followed in order to establish a baseline respiration, which was followed by a CO2 -response test involving exposure to increasing percentages of …
-
Breath by breath analysis of breathing pattern in health and disease: a potential outcome measure for breathing retraining?
… was tested for its validity in comparison to a pneumotachograph (PT). The first study sought to validate the measurements obtained from the LifeShirt ®against PT when calibrated with a published but yet to be tested method for breath by breath analysis and to address the limitations of existing …
-
Recording methods of respiratory parameters in cattle
… parameter in lung function diagnostics, by a pneumotachograph, the animals have to be restrained during the entire experiment and since the behavior is severely restricted by the mask, only short measurement periods are possible. Therefore, the driving force for Publication "B" was to …
-
Effects of changes in inspired gas composition on ventilation and breathing pattern in awake and hibernating ground squirrels
… ventilation was measured using a face-mask and pneumotachograph. S. lateralis exhibited CSR, while S. columbianus showed only single breaths. Both species had similar overall levels of ventilation and continued to show similar ventilatory responses to hypoxic and hypercapnic gas mixtures. Due to …
-
Novas metodologias de avaliação e intervenção em pacientes com Esclerose lateral amiotrófica
… was calculated by subtracting ΔVao (measured by pneumotachograph) and ΔVCW (measured by optoelectronic plethysmography) during air stacking and total lung capacity was estimated by applying Boyle-Mariote's law; 2) Phase angle (θ) between pulmonary ribcage (RCp), abdominal ribcage (RCa) and …
-
Sleep/wakefulness versus urethane anesthesia: analogous arousal states for respiratory control?
… animals, and using a face mask and pneumotachograph in the anesthetized animals. Golden-mantled ground squirrels spent approximately 33% of the time in wakefulness(W), 31% to 14% in light sleep (LS) and 32% to 48% in slow-wave sleep (SWS). Less than 5%of the time was spent in …
-
Měření dechové frekvence
Bakalářská práce se zabývá možnými způsoby měření dechové frekvence. Zaměřuje se na popis struktury jednotlivých zařízení sloužících k měření dechové frekvence, včetně snímačů, které jsou k tomuto účelu využívány. Na závěr teoretické části je zmíněna možnost využití měření dechové frekvence v …
-
Program pro spirometrická měření
Tato práce je zaměřena na metody funkčního vyšetření plic. První část se zabývá základními respiračními údaji, ventilačními poruchami a parametry pro jejich hodnocení. V části druhé podrobněji popisuje jednotlivé diagnostické metody využívané k získávání plicních funkčních parametrů s podrobnějším …
-
Optimising mechanical insufflation-exsufflation therapy in patients with neuromuscular disease
… overestimated PCF by 33 L/min compared to pneumotachograph measurements but demonstrated excellent repeatability with coefficients of variation below 2.5%. Increasing insufflation and exsufflation pressure showed dose-dependent effects on peak flows, though notably, pressure bias was not …