Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 15 of 15 for “"polyethylene insert"”
-
The micromotion between the polyethylene insert and the tibial tray in total knee prostheses
… have suggested a causal relationship between polyethylene (PE) wear debris and aseptic loosening. A few retrieval studies of failed implants have indicated significant back surface wear, but attempts to measure this wear have been scarce. The primary emphasis of this study is the measurement …
-
Posterior stabilized knee design biomechanical considerations
… internal/external femoral rotation, tibial polyethylene insert modularity with the tibial tray and tibial polyethylene insert conformity with the femoral condyles are reviewed. A survey of designs on the market indicates a wide range of results for bone conservation for the femoral housing …
-
Εκτίμηση της αποτελεσματικότητας των αρθρωτών στροφικών αρθροπλαστικών γόνατος, μελετώντας μεσοπρόθεσμα την εφαρμογή της ενδοπρόθεσης solution RT
… mechanism but also a case of a twice broken polyethylene insert. These events were the reason to conduct a biomechanical study. Retrievals were analyzed and a cascade of events were noted in knee hyperextension so that abnormal motion can result, leading to the deformation or even breakage of …
-
Effect of Total Knee Replacement Conformity on Articular Constraint in Mechanical Testing
… the ratio of the femoral component radii and the polyethylene insert radii in the sagittal plane, with more similar radii predicted to provide more articular constraint. The broad objective of this thesis was to understand the role of TKR conformity for providing articular constraint to resist …
-
Design and integration of an instrumented knee prosthesis
… middle part of the prosthesis, constituted of a polyethylene insert located between the metallic parts of the artificial joint and whose function is to reduce the rubbing. An original encapsulation was designed to guarantee the bio-compatibility of the instrumented prosthesis and to avoid a …
-
Biomechanical analysis of fixed bearing and mobile bearing total knee prostheses
… designs by allowing axial mobility between the polyethylene insert and tibial tray. Despite the hypothetical benefits of the MB design, few studies have objectively analysed knee biomechanics during activities of daily living (ADLs) in the laboratory compared to FB designs. This thesis aimed to …
-
Optimisation of the bearing surface design of total knee replacements
… cobalt-chrome tibial tray with a double-concave polyethylene insert. The longevity of knee replacements is limited, as the polyethylene suffers from fatigue resulting in delamination wear. Previous researchers have analysed the stresses produced in tibial inserts of different designs. However, …
-
A Method to Calculate the Femoro-Polyethylene Contact Pressures in Total Knee Arthroplasty In-Vivo
… contact pressures on the superior side of the polyethylene in total knee arthroplasty (TKA) based on in-vivo kinematic data. Ten clinically successful subjects (five fixed and five mobile bearing TKA), having Hospital for Special Surgery (HSS) knee scores greater than 90, were analyzed under …
-
Working principle of the dual mobility (total hip replacement): wear mechanisms and design optimization
… of a big head closer to the native one. Thus a polyethylene insert was added between the metallic metal back and the femoral head but some concerns remained, particularly the cup wear. To keep on improving the dual mobility cup, the first point was to understand how it is working. Therefore …
-
Characterization of Potential Wear Sources in Knee Arthroplasty Prostheses After In Vivo Function
… between femoral component surface roughness, polyethylene insert damage and in vivo duration through the evaluation of metal-polymer UKA bearing couples that were retrieved after 1 to 19 years of in vivo service. This study characterizes the distribution of damage on matched metal-polymer …
-
In Vivo Mechanics of Cam-Post Engagement in Fixed and Mobile Bearing TKA and Vibroarthrography of the Knee Joint
… This study suggests that mobility of the polyethylene plays a significant role in ensuring proper cam-post interaction in RP-PS TKA. The polyethylene insert rotates axially in accord with the rotating femur, maintaining central cam-post contact. This phenomenon was not observed in the …
-
Effect of unicompartmental knee replacement tibial component design on proximal tibial strain and ongoing pain
… mobile bearing UKR implant (n=289) and an all-polyethylene (AP) fixed bearing UKR implant (n=111) with minimum 5 year follow up. A method of digital radiological densitometry, the greyscale ratio b (GSRb), was developed, validated and applied to plain radiographs to measure changes in bone …
-
Biomechanics analysis of motion-gait in patients subjected in two different types of total knee arthroplasty 1. Medial Pivot and 2. Rotating platform posterior stabilized with posterior cruciate ligament sacrifice: kinetics data comparison 2 to 3 years postoperatively
… One such main factor is the wear of the polyethylene insert. Most of the researchers try to approach wear by studying primarily the sagittal and secondly the frontal plane biomechanics. Nevertheless transverse plane biomechanics are equally important for the study of wear even if the main …
-
Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty
… same magnitude for the flat versus the concave inserts in study 3 and the concave versus the PS designs in study 4. The positioning of the implant and the fulfilment of the patients expectations on the surgery preoperatively did not differ. The AMK prosthesis migrated at about the same amount as …
-
Μακροπρόθεσμα αποτελέσματα επιφανειακής ολικής αρθροπλαστικής γόνατος με ασύμμετρους κνημιαίους κονδύλους (GENESIS I)
… consisted of a femoral, a tibial component, a polyethylene insert and a polyethylene patella component. The femoral and the tibial components were placed with the use of cement. It is an easy-to-use system featuring an anatomic, chrome - cobalt femoral component with a wide, deep and extended …