Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 120 for “"polymer gel"”.

  1. Ionic liquid based polymer gel electrolytes

    … investigates the use of ionic liquid-based polymer electrolytes (ion gels) as a gate insulator material for thin-film transistors. The first objective of thesis is to study the electrical properties of ion gels systematically to understand how the ion gels work as a capacitor to accumulate …

    umn Repository record for Ionic liquid based polymer gel electrolytes (opens in a new tab)

  2. Oligomer-polymer gel spinning of high performance fibers

    High performance polymer fibers are playing more important roles than before with increasing needs from more fields. However, the production and commercialization of such fibers are still limited due to high cost especially for those which are produced by gel spinning. The current gel spinning …

    gatech Repository record for Oligomer-polymer gel spinning of high performance fibers (opens in a new tab)

  3. Applications of x-ray computed tomography polymer gel dosimetry

    … these advances. X-ray computed tomography (CT) polymer gel dosimetry is a unique type of dosimeter that has many advantages and the potential to address some of the challenges in the verification of dose delivery and calculation in radiation therapy. This dissertation investigates the …

    uvic Repository record for Applications of x-ray computed tomography polymer gel dosimetry (opens in a new tab)

  4. Improved Recipes for Polymer Gel Dosimeters Containing N-Isopropylacrylamide

    … dose response and ease of manufacture of polymer gel dosimeters that use N-isopropyl acrylamide (NIPAM) as the monomer. An alternative carageenan gelling agent was tested in place of gelatin. Although the carageenan did reduce the gelling time for the dosimeter solution, the dose response …

    queens Repository record for Improved Recipes for Polymer Gel Dosimeters Containing N-Isopropylacrylamide (opens in a new tab)

  5. Recipe Improvement and Mathematical Modelling of Polymer Gel Dosimeters

    A mathematical model for polymer gel dosimeters was extended to simulate the effects of radiation depth doses of various radiation beams on the mass of polymer formed. The influences of monomer diffusion and temperature variation were investigated and predicted by the model. Simulation results …

    queens Repository record for Recipe Improvement and Mathematical Modelling of Polymer Gel Dosimeters (opens in a new tab)

  6. Methods of Investigating Collapse in Colloid-Polymer Gel Systems

    Weak colloid-polymer gels are susceptible to delayed collapse, which occurs as a<br/>result of ageing processes within the internal structure of the gel network. Much<br/>prior work has focussed on analysis from either a macroscopic or microscopic<br/>viewpoint; this work bridges this gap in …

    bristol Repository record for Methods of Investigating Collapse in Colloid-Polymer Gel Systems (opens in a new tab) Download PDF for Methods of Investigating Collapse in Colloid-Polymer Gel Systems (opens in a new tab)

  7. Polymer Gel Dosimetry in Magnetic Resonance-Image Guided Radiation Therapy

    … prior to any routine patient treatment. Polymer gel detectors have previously been shown to be a useful tool to capture complex 3D dose distributions with steep dose gradients using an MR scanner for readout. Their properties make them favorable devices for the development of quality …

    houston Repository record for Polymer Gel Dosimetry in Magnetic Resonance-Image Guided Radiation Therapy (opens in a new tab)

  8. Development of Polymer Gel-Supported Lipid Bilayer Using Capillary-Assisted Assembly

    … such as solid-supported lipid bilayer (SLB) and polymer-supported lipid bilayer with a polymer layer thickness of several nm, were found to be perturbed by the nearby solid substrate. To overcome this limitation, the present work describes for the first time the capillary-assisted formation of a …

    iupui Repository record for Development of Polymer Gel-Supported Lipid Bilayer Using Capillary-Assisted Assembly (opens in a new tab)

  9. Simulation Study of Polymer Gel Application in Enhanced Oil Recovery Processes

    … oil recovery (EOR) processes. The capacity of polymer gel as a blocking agent applied in a heavy oil field to recover oil, however, still remains unclear. A numerical simulation approach is used to investigate the connection and difference between secondary and tertiary recovery techniques to …

    calgary Repository record for Simulation Study of Polymer Gel Application in Enhanced Oil Recovery Processes (opens in a new tab)

  10. NMR studies of ionic mobility in PVDF based polymer gel electrolytes

    … the ionic mobility of liquid electrolytes and polymer gel electrolytes based on poly(vinylidene) uoride (PVDF), propylene carbonate (PC) and lithium tetra uoroborate (LiBF4). Self diffusion measurements were carried out using the resonant frequencies of hydrogen (1H), lithium (7Li) and uorine …

    whiterose Download PDF for NMR studies of ionic mobility in PVDF based polymer gel electrolytes (opens in a new tab)

  11. X-ray computed tomography for performing polymer gel dosimetry : a feasibility study

    … resolution three dimensional (3D) dosimeter. Polymer gels are novel, inherently 3D, tissue equivalent radiation dosimeters. Traditionally, dose distributions recorded in polymer gel are read out using magnetic resonance imaging (MRI). Presented here is a feasibility study on a new 3D dosimetry …

    ubc Repository record for X-ray computed tomography for performing polymer gel dosimetry : a feasibility study (opens in a new tab) Download PDF for X-ray computed tomography for performing polymer gel dosimetry : a feasibility study (opens in a new tab)

  12. Characterization of molecular motions in polymer gel networks using intensity-fluctuation spectroscopy

    … investigate the intrinsic dynamics of synthetic polymer gel networks in terms of cooperative submolecular motions, which give rise to autocorrelation functions, observed by intensity fluctuation spectroscopy. Poly(dimethyl siloxane) samples were purified and chemically crosslinked to three levels …

    rice Repository record for Characterization of molecular motions in polymer gel networks using intensity-fluctuation spectroscopy (opens in a new tab)

  13. 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry

    Polymer gel dosimetry has been used since the 1990s, and several studies have shown that this detector system can be used for verification of static absorbed dose distributions in three dimensions (3D). Its unique properties, such as high resolution, normal tissue equivalence and independency of …

    lund Repository record for 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry (opens in a new tab) Download PDF for 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry (opens in a new tab)

  14. Development of polymer gel systems for lost circulation treatment and wellbore strengthening

    … research was to develop a flowing crosslinked polymer-based drilling fluid by introducing a gelling polymer and a crosslinker to the LCM and drilling mud formulations. The goal is to enhance wellbore strength by increasing the fracture resistance of weak formations to avoid potential mud …

    oklahoma-thes Repository record for Development of polymer gel systems for lost circulation treatment and wellbore strengthening (opens in a new tab)

  15. Impacts of Timing of Crosslinker Addition on Water Shut Off Polymer Gel Properties

    In preparation of gelant solution for making crosslinked polymer gels for water shutoff applications unpublished experiments plus chemical intuition suggest that, unless hydrolyzed polyacrylamide (HPAM) polymer is fully hydrated before addition of crosslinker, the final gel will have lower than …

    tamu Repository record for Impacts of Timing of Crosslinker Addition on Water Shut Off Polymer Gel Properties (opens in a new tab)

  16. Readout of polymer gel dosimeters using a prototype fan-beam optical computed tomography scanner

    … of an advanced dosimeter --- the polyacrylamide, gelatin, and tetrakis (hydroxymethyl) phosphonium chloride (PAGAT) dosimeter --- using a prototype fan-beam optical computed tomography (CT) scanner. A number of developments sought to improve the performance of the optical CT device. A new …

    uvic Repository record for Readout of polymer gel dosimeters using a prototype fan-beam optical computed tomography scanner (opens in a new tab)

  17. Evaluation of Polymer Gel Dosimeters For Measurements of Dose and Let In Proton Beams

    This project assessed the effectiveness of polymer gel dosimeters as tools for measuring the dose deposited by and LET of a proton beam. A total of three BANG® dosimeter formulations were evaluated: BANG®-3-Pro-2 BANGkits™ for dose measurement and two BANG®-3 variants, the LET-Baseline and …

    uthsc Repository record for Evaluation of Polymer Gel Dosimeters For Measurements of Dose and Let In Proton Beams (opens in a new tab)

  18. Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry

    … techniques. It is hypothesized that deformable polymer gels can provide volumetric dosimetric information for the assessment of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos. This hypothesis will be investigated by (1) using stationary polymer gel dosimeters (PGDs) to …

    ubc Repository record for Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry (opens in a new tab) Download PDF for Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry (opens in a new tab)

  19. An x-ray computed tomography polymer gel dosimetry system for complex radiation therapy treatment verification

    X-ray computed tomography (CT) polymer gel dosimetry (PGD) is an attractive tool for three-dimensional (3D) radiation therapy (RT) treatment verification due to the availability of CT scanners in RT clinics. Nevertheless, wide-spread use of the technique has been hindered by low signal-to-noise CT …

    uvic Repository record for An x-ray computed tomography polymer gel dosimetry system for complex radiation therapy treatment verification (opens in a new tab)

Page 1 of 6