Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"position monitoring"”.

  1. Stepping motor control and position monitoring

    … a relatively small displacement, without a shaft-position sensor or special compensation. This provides accurate control of motor position. This thesis describes the development of stepping motor torque characteristics and the different approaches stepping motor phase current waveform detection. …

    njit Repository record for Stepping motor control and position monitoring (opens in a new tab)

  2. Beam position monitoring in the clic drive beam decelerator using stripline technology

    … to the neighboring devices, including the Beam Position Monitors (BPM). According to the CLIC Conceptual Design Report (CDR), an ef ficient beam position monitoring system for the CLIC DB decelerator needs to meet the following requirements: - It should be as simple and economic as possible, as …

    upv Repository record for Beam position monitoring in the clic drive beam decelerator using stripline technology (opens in a new tab)

  3. The development and implementation of a beam position monitoring system for use in the FONT Feedback System at ATF2

    … system being developed to correct the beam position jitter in the extraction line and final focus system at the Accelerator Test Facility (ATF2), Tsukuba, Japan. FONT5 is currently being tested and is used to correct the intra-train jitter for a 3-bunch train; the bunch spacing is 154ns. …

    oxford Repository record for The development and implementation of a beam position monitoring system for use in the FONT Feedback System at ATF2 (opens in a new tab)

  4. Advances in real-time thoracic guidance systems

    … points available via electromagnetic: EM) position monitoring. Technology from Calypso Medical allows for simultaneous tracking of up to three implanted wireless transponders. Additionally, Medtronic Navigation uses wired electromagnetic tracking to guide surgical tools for image guided …

    wustl Repository record for Advances in real-time thoracic guidance systems (opens in a new tab)

  5. A soft robot with three dimensional shape sensing and force recognition multi-modal sensing via tunable soft optical sensors

    … 3D shape sensing and a gripper with tip position monitoring along with contact force recognition and sensing. This robot is tested in a mock laparoscopic setup to prove the effectiveness to be implemented into minimally invasive medical robotic systems.

    bu Repository record for A soft robot with three dimensional shape sensing and force recognition multi-modal sensing via tunable soft optical sensors (opens in a new tab)

  6. Development of a beam position monitor based on Cherenkov diffraction radiation for the AWAKE experiment at CERN

    … and have a few ps bunch length. The independent position monitoring of both beam bunches is mission critical to ensure a perfect overlap of their trajectories in the plasma cell. Unfortunately, the current electron beam position monitoring (BPM) system operates at 404 MHz, in a spectral region …

    oxford Repository record for Development of a beam position monitor based on Cherenkov diffraction radiation for the AWAKE experiment at CERN (opens in a new tab)

  7. Movement Behavior and Habitat Selection of the Endangered June Sucker (<i>Chasmistes liorus</i>) in Utah Lake, Utah

    … four seasonal time-periods. Manual and fixed position monitoring methods were used to collect fish abundance data for all tagged fish. Tagged fish were monitored at the mouth of spawning tributaries to determine the extent of spawning congregations and migrations. Lake-wide fish distributions …

    utahstate Repository record for Movement Behavior and Habitat Selection of the Endangered June Sucker (<i>Chasmistes liorus</i>) in Utah Lake, Utah (opens in a new tab)

  8. The SLD vertex detector upgrade (VXD3) and a study of bbg events

    … performed very close to design specifications. Monitoring the position of VXD3 is crucial for reconstructing the data in the detector for physics analysis. This was carried out using a capacitive wire position monitoring system. The system indicated that VXD3 was very stable during the whole of …

    brunel Repository record for The SLD vertex detector upgrade (VXD3) and a study of bbg events (opens in a new tab)

  9. Investigations into the design of a wheelchair-mounted rehabilitation robotic manipulator

    … speeds, reprogrammable memory locations and position monitoring of each joint. The integration of rehabilitation robotic manipulators into the daily lives of the physically disabled and elderly will significantly influence the role of personal rehabilitation in the next century.

    middlesex Download PDF for Investigations into the design of a wheelchair-mounted rehabilitation robotic manipulator (opens in a new tab)

  10. Monitorování polohy s pomocí GPS/GSM modemu

    … ve vývojovém prostředí Microsoft Visual C++, pro monitoring polohy pomocí GPS/GSM modemu. První program je pouze jakýmsi alternativním řešením pro příjem GPS souřadnic pomocí AT příkazů. Slouží tedy pouze pro výpis vybraných souřadnic do okna terminálu. Druhou aplikaci lze označit za stěžejní část …

    brno-tech Repository record for Monitorování polohy s pomocí GPS/GSM modemu (opens in a new tab)

  11. Development of a Conducting Polymer based Flexible Position Sensor for the Control of Hand Exoskeletons

    … sensors being employed to determine the finger position. These sensors utilise mechanical designs that require physical movements of rigid components. As such, these sensors are bulky and heavy. They inhibit the usability and portability of the hand exoskeleton that prevent a comfortable usage …

    auckland-ms Repository record for Development of a Conducting Polymer based Flexible Position Sensor for the Control of Hand Exoskeletons (opens in a new tab)

  12. Neuroanatomical studies of human extraocular muscles

    … add credence to alternative explanations for eye position monitoring, in particular the efference copy hypothesis.

    city-london Download PDF for Neuroanatomical studies of human extraocular muscles (opens in a new tab)

  13. Development of the Beam Position Monitors for the Diagnostics of the Test Beam Line in the CTF3 at CERN

    … devices called Inductive Pick-Ups (IPU) for Beam Position Monitoring (BPM). A full set of 17 BPM units (16 + 1 spare), named BPS units, were built and installed into the Test Beam Line (TBL), an electron beam decelerator, of the 3rd CLIC Test Facility (CTF3) at CERN ¿European Organization for the …

    upv Repository record for Development of the Beam Position Monitors for the Diagnostics of the Test Beam Line in the CTF3 at CERN (opens in a new tab)

  14. Management of Respiratory Motion in Radiation Oncology

    … respiratory motion affects the instantaneous position of almost all structures in the thorax and abdomen to different degrees based on their corresponding anatomic location and muscular attachments. As an example, diaphragm motion was found to be of the order of 1.5 cm, predominantly in the …

    vcu Repository record for Management of Respiratory Motion in Radiation Oncology (opens in a new tab)