Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 47 for “"position-sensitive detector"”.
-
A position-sensitive detector for hard X-ray astronomy
… the incoming source flux according to the position of the source within the field of view. Hard X-ray detection techniques suitable for use with modulation imagers are reviewed. The recent development of position-sensitive photomultipliers, which are now available in a variety of …
-
Towards Developing a Scanning Position Sensitive Detector (PSD) Microscopy: PSD Measurement Enhancement, Adaptive Local Scanning and Implementation
A Position Sensitive Detector/Device (PSD) is a sensor that is capable of trackingthe location of a laser beam on its surface. PSDs are used in many scientific instrumentsand technical applications including but not limited to: Atomic-force microscopy(AFM), human eye movement monitoring, mirrors or …
-
Absolute Differential Cross-Sections for Small-Angle Charge-Transfer Collisions at keV Energies
… angular range is extended to 7.8$\sp\circ$). A position-sensitive detector is used to detect both the primary and scattered particles. The data typically exhibit striking oscillations. Theoretical calculations for some of the reactions yield good agreement with the measured cross sections. The …
-
Improvements to detection efficiency and measurement accuracy in Coulomb Explosion Imaging experiments
… from a Coulomb Explosion Imaging (CEI) position sensitive detector (PSD) is developed and compared with previously employed schemes. The PSD is calibrated using a newly designed grid overlay and validates the quality of the described algorithm. Precision calculations are performed to …
-
Differential cross sections for neutral-neutral and charge-transfer collisions
… 15eV oxygen ions over the same angular range. A position sensitive detector is used to detect both the primary and scattered particles, yielding absolute differential cross sections. Target chambers with small ratios of length to exit aperture diameter are used and the end effects due to gas …
-
Small angle neutron scattering at 4.3 MeV from heavy elements
… polyethylene deuterium targets. The use of a position sensitive detector in the associated particle technique was demonstrated. Data was accumulated by an on-line computer system. The differential scattering cross section for 4.3 MeV neutrons was measured for scattering samples of uranium, …
-
X-ray emission spectroscopic study of chloride solid compounds using synchrotron radiation
… and polarization dependence. A two-dimensional position-sensitive detector system with data acquisition software is developed for the spectrometer that allows collecting a complete x-ray emission spectrum simultaneously. Mechanical supports for detector mounting and a holder for solid samples …
-
DIFFERENTIAL CROSS SECTIONS FOR NEUTRAL-NEUTRAL COLLISIONS
… based on the use of a micro-channel plate position-sensitive detector, has been developed for studying some of these collision processes. Differential cross sections have been measured over a primary beam energy range of 500eV to 5000eV for the scattering of atomic hydrogen, helium, and …
-
Measurements of optical properties of bulk and thin film semiconductors using the PDS technique
… omitted] for the deflecting medium and a linear position sensitive detector. The spectra obtained for GaAs and GaNAs were compared with models based on the Rosencwaig-Gersho and the Fernelius theories of ID heat diffusion which consider absorption in respectively one and two sample layers, and …
-
The design and performance of an x-ray emission spectrometer using the polarized Kalpha spectra of chlorine and potassium
… the resulting radiation with a resistive anode position sensitive detector; both of which are situated on a Rowland circle. A sample is fixed in position and located in the middle of the Rowland circle. The spectrometer can be positioned to detect fluorescence emitted at 0° and 90° with …
-
Energy Distribution of Sputtered Neutral Atoms from a Multilayer Target
… of the energy distribution was achieved with a position-sensitive detector. The principle behind the detector's energy resolution is time of flight (TOF) spectroscopy. For this specific detector, programmed time intervals between the sputtering pulse at the target and the ionizing laser pulse …
-
Studying the mechanical response of outer hair cells to electric pulses using image sensors
… first design utilizes the position sensitive detector (PSD) S3932 made by Hamamatsu Inc. This detector, however, required excessive intensity of the optical signal that was not compatible with the operation of the overall system.</p><p>The second design investigates the use …
-
High-Resolution, Non-contact Angular Measurement System for PSA/RSA
… be reliably measured in-situ using a laser and position sensitive detector (PSD) technology. A prototype of the measurement system has been built using simple and inexpensive equipment. This device will allow a continuous measurement between the parked position on the ramp and the loading …
-
Development of high-throughput imaging mass spectrometry
… transferred onto a two-dimensional position-sensitive detector. The detected ions are converted to light and recorded by either, a charged coupled device (CCD) camera and a photo multiplier tube (PMT), or an event-triggered complementary metal-oxide semiconductor (CMOS) sensor. CMOS …
-
Mcnp6 Code Development for One Dimensional Position Sensitive Thermal Neutron Detectors
The development of position sensitive thermal neutron detectors (PSD’s) began soon after the initial development of early model thermal neutron detectors. One dimensional (1D) PSD’s report not only neutron counts but the axial position of the neutron interaction within the detector gas volume. …
-
A new experimental technique to study carbon dioxide in the critical region.
… which utilized a diverging x-ray beam and a position sensitive detector, was used to determine density profiles for carbon dioxide in the critical region. This x-ray technique, which does not depend on the determination of the dielectric constant, offered a means by which previous values of …
-
Quantitative small angle light scattering of liquid crystalline copoloyester films
… technology to allow for a two-dimensional position sensitive detector SALS. Using this detector, the compression molded films of PET/POB were found to be composed of randomly ordered fibrillar domains, that do not orient upon cold stretching. Also, the size of these domains were found to be …
-
The interaction of potassium(nd) Rydberg atoms with an amorphous gold surface
… to the surface. The ions are detected by a position-sensitive detector (PSD). At some critical value of the external field, the ion trajectories just miss the surface, suggesting that analysis of the dependence of the ion signals on external electric field can be used to determine the …
Page 1 of 3