Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 72 for “"positive-sequence"”.

  1. The OGCleaner: Detecting False-Positive Sequence Homology

    … rely on using heuristics based on pairwise sequence comparison to identify homology clusters. We propose the Orthology Group Cleaner (the OGCleaner) as a method to evaluate cluster level verification of putative homology clusters in order to create higher quality phylogenetic tree …

    byu Repository record for The OGCleaner: Detecting False-Positive Sequence Homology (opens in a new tab) Download PDF for The OGCleaner: Detecting False-Positive Sequence Homology (opens in a new tab)

  2. Molecular Evolution of Odonata Opsins, Odonata Phylogenomics and Detection of False Positive Sequence Homology Using Machine Learning

    … (LWS) opsin classes were subjected to strong positive selection that greatly weakens after multiple duplication events, a pattern that is consistent with the permanent heterozygote model. Due to the immense interspecific variation and duplicability potential of opsin genes among odonates, they …

    byu Repository record for Molecular Evolution of Odonata Opsins, Odonata Phylogenomics and Detection of False Positive Sequence Homology Using Machine Learning (opens in a new tab) Download PDF for Molecular Evolution of Odonata Opsins, Odonata Phylogenomics and Detection of False Positive Sequence Homology Using Machine Learning (opens in a new tab)

  3. ESTIMATION OF TRANSMISSION LINE PARAMETERS USING LINEAR METHOD WITH SYNCHRONIZED AND UNSYNCHRONIZED DATA

    … distance relays whose zone settings are based on positive sequence line impedance. The research is devoted to estimating transmission line positive-sequence parameters from synchronized or unsynchronized measurements of voltage and current phasors that are obtained at both terminals of the line. …

    uky-thes Repository record for ESTIMATION OF TRANSMISSION LINE PARAMETERS USING LINEAR METHOD WITH SYNCHRONIZED AND UNSYNCHRONIZED DATA (opens in a new tab)

  4. Sensitivity analysis of impedance-based fault location methods

    … fault voltage and current data along with the positive- and zero-sequence line impedance values (in ohm per unit length) to estimate the reactance or distance to fault location. Inaccuracies in line impedance values, which arise from circuit model errors, have an adverse impact on fault …

    texas Repository record for Sensitivity analysis of impedance-based fault location methods (opens in a new tab)

  5. Dynamic modelling and simulation of electric power systems using the Newton-Raphson method

    … method. It addresses both the development of a positive sequence dynamic power flow algorithm for the dynamic study of balanced power systems and a fully-fledged three-phase dynamic power flow algorithm for the dynamic study of power systems exhibiting a significant degree of either structural …

    glasgow Download PDF for Dynamic modelling and simulation of electric power systems using the Newton-Raphson method (opens in a new tab)

  6. A microprocessor-based system for protecting busbars

    … for protecting busbars. The technique uses positive-sequence and negative-sequence models of the power system in a fault-detection algorithm. While phase voltages and currents are used to detect faults, parameters of the power system are not used. Only the arguments of the positive-sequence …

    sask Repository record for A microprocessor-based system for protecting busbars (opens in a new tab)

  7. Measurement calibration/tuning & topology processing in power system state estimation

    … VI investigates the errors introduced in the positive sequence state estimation due to the usual assumptions of having fully balanced bus loads/generations and continuously transposed transmission lines. Several tests are conducted using different assumptions regarding the availability of …

    tamu Repository record for Measurement calibration/tuning & topology processing in power system state estimation (opens in a new tab)

  8. CARRIER SIGNAL INJECTION BASED SENSORLESS CONTROL OF PERMANENT MAGNET BRUSHLESS AC MACHINES

    … experimental measurement, it is proven that the positive sequence carrier current distortion resulting from inverter nonlinearity effects can be used to compensate the influence of inverter nonlinearity on negative sequence carrier current. Hence, a new online post-compensation scheme is …

    whiterose Download PDF for CARRIER SIGNAL INJECTION BASED SENSORLESS CONTROL OF PERMANENT MAGNET BRUSHLESS AC MACHINES (opens in a new tab)

  9. Modelling, Control and Performance of Large-Scale Grid-Connected Solar Photovoltaic Power Plants Under Static and Dynamic Conditions Considering No Energy Storage

    … main controller strategies: controlling only the positive-sequence, controlling positive- and negative sequences and individual control of the phase currents. Dealing with the positive-sequence control of the currents, inverter disconnection issues are addressed for single-stage dc-ac and …

    unsw Repository record for Modelling, Control and Performance of Large-Scale Grid-Connected Solar Photovoltaic Power Plants Under Static and Dynamic Conditions Considering No Energy Storage (opens in a new tab)

  10. LARGE DEVIATIONS FOR SELF INTERSECTION LOCAL TIMES OF ORNSTEIN-UHLENBECK PROCESSES

    … P{Yn ∈ A} ≈ exp{−bnI(A)} (n → ∞), for a random sequence {Yn}, a positive sequence bn with bn → ∞, and a coefficient I(A) ≥ 0. In applications, we often concern about the probability that the random variables take large values, that is we concern about the P{Yn ≥ λ}, where λ > 0. Here, we …

    utk-theses Repository record for LARGE DEVIATIONS FOR SELF INTERSECTION LOCAL TIMES OF ORNSTEIN-UHLENBECK PROCESSES (opens in a new tab)

  11. Interior Permanent Magnet Synchronous Motor Demagnetization Fault Modeling and Analysis by Using Dynamic Phasors Model

    … the time-domain transient simulations of positive sequence currents are shown and compared to the conventional dq0 model with demagnetization fault.

    ndsu Repository record for Interior Permanent Magnet Synchronous Motor Demagnetization Fault Modeling and Analysis by Using Dynamic Phasors Model (opens in a new tab)

  12. Interfacing dynamic phasor based system equivalents to an electromagnetic transient simulation

    … model and the dynamic phasor model. Two types of positive sequence filters i) sinusoidal signal integrator phase locked loop ii) extended phase locked loop are presented to eliminate the voltage unbalance effect in a phase locked loop. A comparison of the performance of the two filters is …

    manitoba Repository record for Interfacing dynamic phasor based system equivalents to an electromagnetic transient simulation (opens in a new tab)

  13. Adaptive Phase Locked Loops for VSC connected to weak ac systems

    … topology which extracts the fundamental positive sequence component of the input voltage, to be fed into the SRF-PLL for tracking of its phase angle. Compared with other traditional PLL topologies, this Adaptive PLL shows superior immunity to voltage distortions, and also has a faster …

    manitoba Repository record for Adaptive Phase Locked Loops for VSC connected to weak ac systems (opens in a new tab)

  14. Towards Three-Phase Dynamic Analysis of Large Electric Power Systems

    … dynamic simulations without assuming a positive sequence network model. As a result, TPDA can be used for more accurate investigation of electromechanical transients in the electric grid in the presence of imbalances. At present, the Electromagnetic Transient Program (EMTP) software can …

    vt Repository record for Towards Three-Phase Dynamic Analysis of Large Electric Power Systems (opens in a new tab)

  15. Advances to the dynamic security assessment of power systems with grid-forming resources: A multivariate polynomial approach

    … plants. The GFM power plants are modeled in the positive-sequence domain and are capable of riding through faults using analytic saturation functions. This thesis is significant to assist grid operators and planners of the future to conduct DSA of grids powered by GFM power plants.

    iastate Repository record for Advances to the dynamic security assessment of power systems with grid-forming resources: A multivariate polynomial approach (opens in a new tab)

  16. Fault Ride Through of Microgrid with Grid-forming Inverters

    … ride through potential of the system, negative sequence control layer is added along with positive sequence droop control layer and the new system’s fault ride through characteristics are studied. In addition, this study the fault ride capacity of the grid forming microgrid with droop …

    ttu Repository record for Fault Ride Through of Microgrid with Grid-forming Inverters (opens in a new tab)

  17. Measurement of power system subsynchronous impedances and comparison with computer simulations

    … to measure the equivalent (driving point) positive sequence impedance, as a function of frequency, of an operating power system. The technique used is to apply a phase-to-phase fault at the system node of interest and record the transient voltage across and current in the fault. These …

    ubc Repository record for Measurement of power system subsynchronous impedances and comparison with computer simulations (opens in a new tab) Download PDF for Measurement of power system subsynchronous impedances and comparison with computer simulations (opens in a new tab)

  18. A universal centralized protection scheme for feeders of AC microgrids using IEC-61869-9 digital instrument transformers

    … impedance disparities using both feeder ends’ positive sequence voltage and current measurements. This value approximates zero during normal operation but deviates during a fault, enabling effective fault detection. The proposed protection philosophy was rigorously tested through simulations, …

    uoit Repository record for A universal centralized protection scheme for feeders of AC microgrids using IEC-61869-9 digital instrument transformers (opens in a new tab)

  19. Transmission line protection with a digital computer

    … on fault type, and finally calculates the positive sequence impedance of the line. The method is shown to be suitable for extension to use in a multi-line situation. Some computer specifications are outlined for this task.

    unsw Repository record for Transmission line protection with a digital computer (opens in a new tab)

  20. The asymptotic behavior of the convolution product of real-valued sequence

    <p>The convolution product of real-valued sequences {a<sub>n</sub>} and {b<sub>n</sub>} is a new sequence {c<sub>n</sub> } defined by </p><p>c<sub>n</sub> = &sum; a<sub>j</sub>b<sub>n-j</sub> (n = 0, 1, ,2, ...) .</p> <p>The purpose of this thesis is to describe the asymptotic behavior of …

    ut-knoxville Repository record for The asymptotic behavior of the convolution product of real-valued sequence (opens in a new tab)

Page 1 of 4