Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"post installed"”.

  1. Retrofit of deficient lap splice with post-installed anchors

    … the capacity of deficient lap splices is to use post-installed undercut anchors. These anchors function as active confinement in the splice region, potentially allowing members with inadequate lap splice lengths to reach the required design capacity. The solution presented in this thesis requires …

    texas Repository record for Retrofit of deficient lap splice with post-installed anchors (opens in a new tab)

  2. Undercut and grouted anchors as post-installed shear reinforcement

    … important. This thesis investigates the use of post-installed undercut and grouted (rods grouted in place) anchors for strengthening reinforced concrete beams in shear. These techniques are especially useful when access to members requiring retrofit is limited. Experimental results are compared …

    texas Repository record for Undercut and grouted anchors as post-installed shear reinforcement (opens in a new tab)

  3. Bond Behavior of Post-Installed GFRP Bars in Structural Connections

    … helical wraps, silica coated and ribbed) used as post-installed (epoxy and cementitious adhesive) and cast-in-place reinforcement. Twenty test specimens were constructed and tested under static load. A test specimen was composed of two identical vertical elements, which were anchored into the base …

    umn Repository record for Bond Behavior of Post-Installed GFRP Bars in Structural Connections (opens in a new tab)

  4. Impact Load Effects on Post-Installed Anchors: An Experimental Investigation

    … to assess the suitability of three proprietary post-installed anchors from Simpson Inc. for use under high strain-rate loading, such as blast loadings, in both tension and in shear. The anchors investigated included two torque-controlled expansion anchors (Strong Bolt® 2, Wedge-All®) and a screw …

    carleton Repository record for Impact Load Effects on Post-Installed Anchors: An Experimental Investigation (opens in a new tab)

  5. Tensile and Shear Capacity of Post-Installed GFRP Bars in Concrete

    Post-installed reinforcing bars are frequently used to connect new concrete members to an existing structure. In these applications, uncoated steel reinforcing bars are often used, which are susceptible to corrosion. The use of glass fiber-reinforced polymer (GFRP) reinforcing bars in structural …

    umn Repository record for Tensile and Shear Capacity of Post-Installed GFRP Bars in Concrete (opens in a new tab)

  6. Behavior and Design of Post-Installed Anchors in Thin Concrete Members

    This dissertation evaluates the behavior and capacity of single screw and adhesive anchors in thin concrete members that do not meet the minimum thickness requirements of current standards for anchorage. This dissertation focuses on the concept of full thickness embedment, wherein anchors are …

    clemson Repository record for Behavior and Design of Post-Installed Anchors in Thin Concrete Members (opens in a new tab)

  7. Strengthening existing steel bridge girders by the use of post-installed shear connectors

    … non-composite floor systems by the use of postinstalled shear connectors. Three types of post-installed shear connection methods were investigated. These methods are referred to as the double-nut bolt, the high tension friction grip bolt, and the adhesive anchor. These post-installed shear …

    texas Repository record for Strengthening existing steel bridge girders by the use of post-installed shear connectors (opens in a new tab)

  8. Strengthening continuous steel girder bridges with post-installed shear connectors and inelastic moment redistribution

    … to be strengthened or replaced to avoid load-posting and to maintain structural safety. One potentially economical method of extending the service life of such bridges is to post-install adhesive anchor shear connectors to create composite action between the existing steel beams and concrete …

    texas Repository record for Strengthening continuous steel girder bridges with post-installed shear connectors and inelastic moment redistribution (opens in a new tab)

  9. Creep Behaviour of Post-Installed Adhesive Anchors under Various Sustained Load Levels and Environmental Exposures

    … in depth, with 15M (No. 5) deformed steel bar post-installed to an embedment depth of six times the bar diameter or 125mm (5 inch). Three types of adhesives were used for anchor installation: Type-A a fast setting two component methyl methacrylate adhesive, Type-B a fast setting two part epoxy …

    waterloo Repository record for Creep Behaviour of Post-Installed Adhesive Anchors under Various Sustained Load Levels and Environmental Exposures (opens in a new tab)

  10. Fatigue behavior of post-installed shear connectors used to strengthen continuous non-composite steel bridge girders

    … existing concrete slab and steel girders using post-installed shear connectors to change the behavior of the beam from non-composite to partially-composite. Since fatigue is one of the main concerns in designing bridges, investigating the fatigue properties of these post-installed shear …

    texas Repository record for Fatigue behavior of post-installed shear connectors used to strengthen continuous non-composite steel bridge girders (opens in a new tab)

  11. Behavior and Design of Post-Installed Connectors in Thin Ultra-High Performance Fiber Reinforced Concrete Members

    Ultra-high-performance fiber reinforced concrete (UHPFRC) has been investigated as a wythe material in insulated double wythe precast concrete (DWPC) panels resulting in thin lightweight wythes while still satisfying structural, thermal, and architectural requirements. However, the connection …

    queens Repository record for Behavior and Design of Post-Installed Connectors in Thin Ultra-High Performance Fiber Reinforced Concrete Members (opens in a new tab)

  12. Strengthening of noncomposite steel girder bridges with post-installed shear connectors : fatigue behavior of the adhesive anchor

    … steel girder bridges through the use of post-installed shear connectors. Bridges potentially eligible for retrofit have noncomposite floor systems, where the concrete slab is not attached to the steel girders with shear connectors. Many of these bridges were designed in the 1950's and …

    texas Repository record for Strengthening of noncomposite steel girder bridges with post-installed shear connectors : fatigue behavior of the adhesive anchor (opens in a new tab)

  13. Anchorage of Epoxy-Coated Rebar Using Chemical Adhesives

    Post-installed reinforcement is used to connect a new concrete member to an existing concrete structure. Typically, uncoated rebar post-installed with a chemical adhesive is used in these applications, which may lead to corrosion. Departments of Transportation and local bridge owners have used and …

    umn Repository record for Anchorage of Epoxy-Coated Rebar Using Chemical Adhesives (opens in a new tab)

  14. Experimental Determination Of The Pull-Out Strength Of Cast-In Lifting Inserts In Precast Hollow-Core Plank

    … and determine the capacity of lifting inserts post-installed into the top of precast hollow-core planks. The insert that was studied is the P-52 "Swift Lift" Insert supplied by Dayton-Superior. Physical testing of 16 inserts was done to aid in determining the tensile capacity of the insert. The …

    marquette Repository record for Experimental Determination Of The Pull-Out Strength Of Cast-In Lifting Inserts In Precast Hollow-Core Plank (opens in a new tab)

  15. Use of innovative anchors for composite action in rehabilitated steel structures

    … have to be replaced or strengthened by utilizing post installed shear connection systems. The advantage of a shear connection system that can be post installed is that they can also be uninstalled. This property could be leveraged to manufacture demountable structures. Two blind bolt connectors …

    unsw Repository record for Use of innovative anchors for composite action in rehabilitated steel structures (opens in a new tab)

  16. Reinforced concrete interfaces under cyclic actions

    … interfaces formed at cold joints, with post-installed bars fastened with adhesives or post-installed mechanical connectors, under cyclic actions. The first experimental part of this study addresses twenty-five (25) short interfaces crossed by a small number of connectors subjected to …

    greece Repository record for Reinforced concrete interfaces under cyclic actions (opens in a new tab)

  17. Pendulum simulation of vehicular impact on retrofit bridge barriers

    … has been damaged by a vehicular collision. Post-installed mechanical anchors are a popular way to fasten structural members to hardened concrete and may be used for retrofit bridge barrier connection designs. The primary criterion for retrofit bridge barrier designs is that they perform …

    texas Repository record for Pendulum simulation of vehicular impact on retrofit bridge barriers (opens in a new tab) Restricted access

  18. Shear Connections for the Development of a Full-Depth Precast Concrete Deck System

    … to investigate the effects of various pre- and post-installed shear connectors, haunch height, surface roughness, grouping effects, and grout composition as compared to cast-in-place specimens. The experimental results are presented along with a method for normalizing the variations of results …

    tamu Repository record for Shear Connections for the Development of a Full-Depth Precast Concrete Deck System (opens in a new tab)

  19. Methods to develop composite action in non-composite bridge floor systems: part I

    … structurally deficient, with about 3500 bridges posted for load, meaning that they do not meet today’s design load ratings. More than one out of every eight bridges is proposed to be replaced, at a cost of $15 billion, because of insufficient capacity or roadway geometry. Economic methods of …

    texas Repository record for Methods to develop composite action in non-composite bridge floor systems: part I (opens in a new tab) Restricted access

  20. Static and dynamic assessment of the influence of asphalt layers on the structural response of steel guardrail posts

    … (usually called “mow strips”) around guardrail posts is common in many states where vegetation growth around and adjacent to the guardrail system is problematic. Recent studies have indicated that these layers can produce excessive ground-level restraint on the post, which may result in …

    gatech Repository record for Static and dynamic assessment of the influence of asphalt layers on the structural response of steel guardrail posts (opens in a new tab)

Page 1 of 2