Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 6 of 6 for “"post-installed anchors"”.

  1. Retrofit of deficient lap splice with post-installed anchors

    … the capacity of deficient lap splices is to use post-installed undercut anchors. These anchors function as active confinement in the splice region, potentially allowing members with inadequate lap splice lengths to reach the required design capacity. The solution presented in this thesis requires …

    texas Repository record for Retrofit of deficient lap splice with post-installed anchors (opens in a new tab)

  2. Impact Load Effects on Post-Installed Anchors: An Experimental Investigation

    … to assess the suitability of three proprietary post-installed anchors from Simpson Inc. for use under high strain-rate loading, such as blast loadings, in both tension and in shear. The anchors investigated included two torque-controlled expansion anchors (Strong Bolt® 2, Wedge-All®) and a screw …

    carleton Repository record for Impact Load Effects on Post-Installed Anchors: An Experimental Investigation (opens in a new tab)

  3. Behavior and Design of Post-Installed Anchors in Thin Concrete Members

    … and capacity of single screw and adhesive anchors in thin concrete members that do not meet the minimum thickness requirements of current standards for anchorage. This dissertation focuses on the concept of full thickness embedment, wherein anchors are embedded through the entire thickness …

    clemson Repository record for Behavior and Design of Post-Installed Anchors in Thin Concrete Members (opens in a new tab)

  4. Undercut and grouted anchors as post-installed shear reinforcement

    … important. This thesis investigates the use of post-installed undercut and grouted (rods grouted in place) anchors for strengthening reinforced concrete beams in shear. These techniques are especially useful when access to members requiring retrofit is limited. Experimental results are compared …

    texas Repository record for Undercut and grouted anchors as post-installed shear reinforcement (opens in a new tab)

  5. Seismic Performance and Shear Strengthening of Precast Hollow-core Floors

    … of an experimental programme that examined the post-cracking residual shear capacity of twelve full-scale hollow-core units. Results showed that web cracking reduced load-bearing capacity by at least 60% of the units' ultimate strength, with instances where the units completely lost capacity …

    auckland-ms Repository record for Seismic Performance and Shear Strengthening of Precast Hollow-core Floors (opens in a new tab)

  6. Pullout Strength of Epoxy Anchors Installed Underwater

    … has on the pullout strength of epoxy anchors. Two different epoxies were tested at embedment depths of two, four, and six bar diameters. These tests utilized three distinct installation procedures under dry and submerged conditions. The testing program occurred over five phases, with …

    calpoly Repository record for Pullout Strength of Epoxy Anchors Installed Underwater (opens in a new tab)