Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 27 for “"potential pulse"”
-
Two new instruments for analytical chemistry: A. Constant potential pulse polarography (CPPP) and differential CPPP (DCPPP) for determination of metals in the presence of oxygen in flowing systems; B. Versatile laser-based analytical instrument for detection of jet-cooled molecular species
… necessity. Detection is accomplished by constant potential pulse polarography (CPPP). The instrument makes feasible detection in flowing samples by elimination of the required oxygen removal step. CPPP further offers a degree of freedom from interference due to reduction of hydrogen ion in acidic …
-
Optimization of Micro-manufactured Human Sensing Platform
… signal transduction mechanism in a double potential pulse method. In brief, HOOH was allowed to accumulate and was then detected by the first potential pulse. The second potential pulse gauged background charge for each consecutive measurement of HOOH. This difference charge (¿Q) was used …
-
Double Pulse Coulometry for Interfacial Biosensing at Platinum Microelectrodes
… cells and tissues. More specifically, a double potential pulse coulometric scheme for cholesterol sensing at platinum microelectrodes was developed and optimized to avoid amperometric measurements needed to reference to a nonzero solution baseline current and baseline shift upon repositioning …
-
Application of polypyrrole for biosensor design and modification of living cells /
… and repulsion possibility of the Ppy film by potential cycling was considered. Comparison of DNA molecularly imprinted polypyrrole (MIPpy) formed by potential pulse sequence and potential cycling showed that MIPpy was formed by both methods, however potential pulse sequence was more suitable. …
-
Polipirolo taikymas biologiniams jutikliams ir gyvų ląstelių modifikavimui /
… and repulsion possibility of the Ppy film by potential cycling was considered. Comparison of DNA molecularly imprinted polypyrrole (MIPpy) formed by potential pulse sequence and potential cycling showed that MIPpy was formed by both methods, however potential pulse sequence was more suitable. …
-
Reducing Residue In Nickel Electroplating Operations
… the formation of anode residue. Applied potentials above the pitting potential resulted in current densities greater than 3 A dm-2 and pit interiors that were markedly different than those of galvanostatic pits at 0.4 A dm-2. Current transients for potentiostatic pulses above the pitting …
-
The pulse clamp method for analyzing neural stimulating electrodes
The Pulse-Clamp (P-C) method was developed and used to analyze the electrochemical behavior of neural stimulating electrodes on the same time scale as typical neural stimulating pulses. The P-C method consists of applying a controlled current stimulating pulse, followed by a controlled potential …
-
Desenvolvimento de procedimentos eletroanalíticos para a determinação simultânea de analgésicos em formulações farmacêuticas e fluidos biológicos empregando o eletrodo de diamante dopado com boro
… based on a flow injection analysis with multiple pulses amperometric detection (FIA-MPA), using as transport solution a 0.05 mol L−1 H2SO4 solution. The potential pulse application sequence in function of time was 950 mV / 200 ms (potential where only the PAR oxidation occurs) and 1400 mV / 100 ms …
-
Detection of metal ions in flow-analyzers by reverse pulse amperometry without interference from dissolved oxygen
<p>Reverse pulse amperometry is introduced as an electroanalytical technique which, when applied with a mercury electrode, is capable of monitoring fluid streams for the presence of electroactive metal ions without the requirement of deaeration. The technique is based on the application of an …
-
HUMAN IN VIVO CHOLESTEROL ANALYSIS BY MICROELECTRODE
… provided by Susu Yuan's thesis (2011). A double potential pulse coulometric scheme for cholesterol sensing at the platinum and carbon disk microelectrodes was applied, which avoids amperometric measurements that requires reference to the solution baseline current and baseline shift upon …
-
Δυναμική ανάλυση της καρδιακής λειτουργίας και μη γραμμική ανάλυση πειραματικών χρονοσειρών σημάτων καρδιακού ρυθμού.: κατασκευή αδρομερούς μοντέλου διάδοσης παλμού μυοκαρδίου
… and analyze a coarse graining model for the potential pulse propagation in human myocardium. The normal propagation is examined according the existence of spiral wave solutions in order to clarify the arrhythmias emergence in myocardium.
-
Fabrication, Characterization, and Application of Carbon Nanoparticles for the Detection of Heavy Metal Ions in Aqueous Media
… accumulation time, reduction time, reduction potential, pulse height, and pulse width. Calibration curves for each metal were produced and detection limits were calculated. The detection limits for Cu2+, Hg2+, and Pb2+ were 0.50 ppm, 31 ppm and 0.30 ppm and the sensitivity of the calibration …
-
Exploring the Mechanism of the Electrostatic Denaturation of Double-Stranded DNA
… other papers in this field show that when the potential on the electrode is alternated between an attractive and repulsive potential at a set frequency, the ions in solution cannot react quickly enough to form the double layer at frequencies higher than 10 kHz. From this, we concluded that …
-
Road to In Vivo Cholesterol Analysis in Human Diagnostics
… during the hold time, and then double potential pulse experiments were conducted on the modified electrodes. The difference of analog charge from first step and second step is an estimate of the accumulated hydrogen peroxide. The modified electrode showed a response at living tissue …
-
Estudo das propriedades químicas, elétricas e da microestrutura de filmes de óxidos coloridos crescidos sobre aço inoxidável por processos químico e eletroquímicos
… (triangular current scan - TCS, alternating potential pulse - APP and superposition of ac and dc signals - SPS) before and after a hardening treatment. Oxide films with two distinct values of thickness (~130 nm e ~200 nm) were obtained using the CHE, TCS and APP colouration processes. The SPS …
-
The development of pulsed waveforms for the electrochemical detection of inorganic and organic compounds in flow-injection analysis and liquid chromatography
… electroactive elements and compounds utilizing pulsed waveforms in flow-injection and liquid chromatographic systems. Particular emphasis is placed on the development of waveforms for the rejection of ubiquitous background interferences as well as for the enhancement of sensitivity and …
-
DETERMINATION OF CHOLESTEROL TRANSPORT REGULATION IN CYSTIC FIBROSIS FOR BOTH BIOMARKER AND THERAPY DEVELOPMENT
… CF biomarkers such as sweat chloride and nasal potential difference (NPD) only reveal information about level of activity of the cystic fibrosis transmembrane conductance regulator (CFTR) by measuring Cl- transport. However, there is a lack of correlation between level of improved Cl- …
-
Planktic and benthic foraminifera as proxies for paleoceanographic change during the Eocene-Oligocene Transition
… Mexico in the latest Eocene. My data indicate a potential pulse of proto-North Atlantic Deep Water flow into the deep Gulf of Mexico prior to Antarctic glaciation, which has important implications for oxygenation of the deep Gulf. Planktic foraminiferal paleoecology and XRF scanning of deep sea …
-
Spatial Fourier Transform for Blind Detection of Radio Observations of Rotating Radio Transients
… for the detection of isolated astrophysical pulses. Unlike the conventional algorithm, which requires de-dispersion, integration over frequency channels and matched filtering, the ETD algorithm detects pulses in a space reciprocal to the space of filterbank data. The ETD algorithm is …
-
Engineering Gold Nanoparticles And Their Use To Control Nucleation
… concentration. Deposition time and applied potential are the other factors controlling the electrodeposition. The smallest particle size was observed with the lowest HAuCl4 concentration. The synthesis of K1.75Pt(CN)4.1.5H2O rods is conducted according to literature on bare HOPG with a …
Page 1 of 2