Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"potentiometric method"”.

  1. A Potentiometric Method for the Determination of Sulfate

    … The literature cites many direct volumetric methods using diphenyl benzidine as indicator. Other methods make use of ethylene diamine tetracetic acid sodium salt for direct precipitation titrations.

    creighton Repository record for A Potentiometric Method for the Determination of Sulfate (opens in a new tab)

  2. Potentiometric Titration of Sulfate Using A Lead-Mercury Amalgam Indicator Electrode

    … and soil saturation extracts were determined potentiometrically using the lead-mercury amalgam indicator electrode and a standard calomel reference electrode. Sulfate concentrations over the range 0.4 to 20 milliequivalents sulfate per liter were determined with an automatic titrator and …

    utahstate Repository record for Potentiometric Titration of Sulfate Using A Lead-Mercury Amalgam Indicator Electrode (opens in a new tab)

  3. ΑΝΑΛΥΤΙΚΕΣ ΕΦΑΡΜΟΓΕΣ ΤΟΥ Ν-ΒΡΩΜΟΣΟΥΚΙΝΙΜΙΔΙΟΥ

    … AND AMMONIUM IONS WERESTUDIED. A KINETIC- POTENTIOMETRIC METHOD IS ALSO DESCRIBED FOR THE DETERMINATION OF ASCORBIC ACID, BIOTIN, PYRIDOXINE AND THIAMINE IN COMMERCIAL PHARMACEUTICAL PREPARATIONS. THE RATE OF PRODUCTION OF BROMIDE IS MONITORED WITH A BROMIDE-SELECTIVE ELECTRODE. A SIMPLE …

    greece Repository record for ΑΝΑΛΥΤΙΚΕΣ ΕΦΑΡΜΟΓΕΣ ΤΟΥ Ν-ΒΡΩΜΟΣΟΥΚΙΝΙΜΙΔΙΟΥ (opens in a new tab)

  4. Hydrogen ion concentration in lead acetate solutions.

    … and to users of chrome yellows. The methods now in use for the analysis of lead acetate are to be reviewed, and an attempt will be made to measure the hydrogen ion concentration of the lead acetate solutions by a potentiometric method. It is proposed, therefore, to measure the …

    louisville Repository record for Hydrogen ion concentration in lead acetate solutions. (opens in a new tab)

  5. Form of Aluminum(III) in Dilute Aqueous Solution

    <p> Using a potentiometric method on 10^-4M and 10^-5M Al(NO3)3 solutions at constant ionic strength (0.1 M KNO3) and temperature (25°C), titration curves were defined and examined with respect to three variables (total aluminum concentration, pH range, and time) in order to assess the …

    mcmaster Repository record for Form of Aluminum(III) in Dilute Aqueous Solution (opens in a new tab)

  6. Nanostructered Aminophenylporphyrin Films for Use in Bulk Heterojunction and Inverse Dye-Sensitized TiO₂ Solar Cells

    … is sensitive to the electrochemical solvent, potentiometric method, and the aminophenyl porphyrin monomer utilized. To elucidate the molecular structure of poly-TAPP and to correlate structures with proposed polymerization and conductivity mechanisms, reflectance FT-IR and …

    portland-state Repository record for Nanostructered Aminophenylporphyrin Films for Use in Bulk Heterojunction and Inverse Dye-Sensitized TiO₂ Solar Cells (opens in a new tab)

  7. Characterization of some products of starch-enzyme digestion

    … modification of Hagedorn and Jensen's sugar method, applicable to following the course of amylase action has been developed;A potentiometric method of determining reducing values during amylase action has been developed;The temperature at which the substrate is prepared has been found to …

    iastate Repository record for Characterization of some products of starch-enzyme digestion (opens in a new tab)

  8. The application of iron oxide based photocatalysts in chromium photoredox chemistry

    … is relatively inert and less toxic. Conventional methods used to eliminate Cr(VI) from aqueous phase include its reduction to Cr(III) at acidic pH by reaction with strong reducing agents such as thiosulphate, FeSO4 and SO2, followed by precipitation as hydroxide in alkaline media. However, this …

    cent-lancashire Download file for The application of iron oxide based photocatalysts in chromium photoredox chemistry (opens in a new tab)

  9. Trapping and detecting charged particles and proteins with high-frequency fields using silicon nanowire field-effect biosensors

    … of the nanowires. Despite the success of this potentiometric method in detecting DNAs, proteins, and viruses, the method suffers greatly from the Debye screening, which arises from the Coulomb interaction of charged species, and the low-frequency noises, and exhibits relatively poor performance …

    bu Repository record for Trapping and detecting charged particles and proteins with high-frequency fields using silicon nanowire field-effect biosensors (opens in a new tab)

  10. Pyrrolizidine alkaloids: Chemical basis of toxicity

    … and toxicity produced by the parent PA. Using a potentiometric method to measure hydrolysis, it was determined that the half-lives of the corresponding DHAs of retrorsine, seneciphylline, monocrotaline and trichodesmine were 1.06, 1.60, 3.39 and 5.36 sec, respectively. These values were supported …

    arizona-thes Repository record for Pyrrolizidine alkaloids: Chemical basis of toxicity (opens in a new tab)

  11. Electrical and thermal characterization of large lithium-ion batteries for non-road mobile machinery applications

    … dissertation proposes efficient and effective methods for the electrical and thermal characterization of lithium-ion batteries. The aim is to reduce the time and effort involved in the experimental testing and parameterization as well as to improve the accuracy of the resulting model. A …

    aalto Repository record for Electrical and thermal characterization of large lithium-ion batteries for non-road mobile machinery applications (opens in a new tab)

  12. Simple and inexpensive biosensors for point-of-care diagnostics

    … devices for point-of-care biosensing, a potentiometric method for analyzing percent hemoglobin A1c (%HbA1c) and a PDMS-glass microelectrochemical device for highly reproducible amperometric measurement in microdroplet, are described. The first paper-based sensing device is fabricated …

    texas Repository record for Simple and inexpensive biosensors for point-of-care diagnostics (opens in a new tab)

  13. Paviršiaus aktyviųjų medžiagų nuotekų vandenyje tyrimas /

    … Kuršėnai town was analyzed. Different research methods were used for the purpose of the study. Total organic matter content was determined by titration according to ChDSCr. The anionic surfactants were analyzed by measuring the absorption intensity of the azure and surface active agents by …

    vilnius Repository record for Paviršiaus aktyviųjų medžiagų nuotekų vandenyje tyrimas / (opens in a new tab)

  14. Διερεύνηση και ανάπτυξη μηχανισμών γενετικής και μεβρανικής τροποποίησης κυττάρων για χρήση σε βιοαισθητήρες

    … GSSG concentrations were measured by the Ellman method. The results showedan increase in the antioxidant enzymes specific activities as well as an increase at themalondialdehyde‘s (MDA) concentration. The insecticides also reduced GSH levels atthe highest concentrations. The same assay was used …

    greece Repository record for Διερεύνηση και ανάπτυξη μηχανισμών γενετικής και μεβρανικής τροποποίησης κυττάρων για χρήση σε βιοαισθητήρες (opens in a new tab)

  15. Determinations of Chemical Equilibria in Natural Waters Using Spectrophotometric Techniques

    … the development of a novel spectrophotometric method, based on the potentiometric method used by Mehrbach et al. (1973), to experimentally determine K2 for a range of temperatures (15 ≤ t ≤ 35 °C) and salinities (20 ≤ S ≤ 40). The K2 values determined in this work, each based on hundreds of …

    usf Repository record for Determinations of Chemical Equilibria in Natural Waters Using Spectrophotometric Techniques (opens in a new tab)

  16. Investigations on metal complexes in solution

    … may be attached to the results found by this method.</p> <p>As illustration, the results obtained by Independent workers for the formation of the two well defined complexes of Cu<sup>2+</sup> with ethylenediamine range from a value of 30% less than the calorimetric value to one 40% in excess …

    oxford Repository record for Investigations on metal complexes in solution (opens in a new tab)

  17. Měření malých stejnosměrných napětí

    Práce se zabývá měřením malých stejnosměrných napětí s využitím tří měřicích metod. První část práce popisuje jednotlivé metody. Jedná se o potenciometrickou metodu, referenční krokovou metodu a přímou metodu. Práce také popisuje kvantový etalon stejnosměrného napětí založený na Josephsonově jevu, …

    brno-tech Repository record for Měření malých stejnosměrných napětí (opens in a new tab)