Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 17 of 17 for “"potentiometric pH"”.
-
Fully printed potentiometric pH sensor
… health monitoring and analysis. In particular, pH measurements can be done non-invasively and continuously, making it an excellent parameter for monitoring different stages of wound healing. Here, we report pH sensitivity of a polyaniline/graphite (PANI/G) composite in a fully-printed …
-
Reference Electrode Techniques for Solid State Potentiometric pH Measurement
… improvement ever made to the conventional potentiometric pH measurement system. This thesis reports on the experimental investigation of several prototype solid state reference electrodes which were designed to eliminate the reliance of conventional potentiometric specific ion glass …
-
Potentiometric pH Measurements in the Pressure Acid Leaching of Nickel Laterites
… reference electrode has been employed to measure pH of high-temperature acidic sulphate solutions relevant to the pressure acid leaching (PAL) of nickel laterites. In a previous study, this cell was used to measure pH of H2SO4, Al2(SO4)3-H2SO4 and MgSO4-Al2(SO4)3-H2SO4 solutions at 250oC. In this …
-
Investigation and development of titanium nitride solid-state potentiometric pH sensor
The measurement of pH value is crucial parameter in various fields like, drinking water monitoring, food preparation, biomedical and environmental applications. The most common device for pH sensing is the conventional pH glass electrode. While glass electrodes have several advantages, such as …
-
Development, manufacture and application of a solid-state pH sensor using ruthenium oxide
The measurement of pH is undertaken frequently in numerous settings for many applications. The common glass pH probe is almost ideal for measuring pH, and as such, it is used almost ubiquitously. However, glass is not ideal for all applications due to its relatively large size, fragility, need for …
-
Procedures for Assessment of the Marine Carbon System and Evaluation of Access and Ocean Acidification Literacy in the Deaf Community
… changes in seawater caused by the uptake of atmospheric CO2, especially in coastal environments. Due to the proximity of anthropogenic stressors in the coastal zone, the biogeochemical complexity of the CO2 system is more dynamic than the open ocean. My principal research objectives were addressed …
-
Electrochemical microsensor system for cell culture monitoring
… continuous measurement technique of chemical and physical parameters in cell culture, which impacts many different areas of biological research. With the focus being on eukaryotic cells, many fields such as standardisation of cell culture, cancer research, individualised (cancer) therapy, as well …
-
Fabrication and characterisation of nanostructured palladium hydride microelectrode pH sensors
… created by a hexagonal lyotropic crystalline phase. While retaining micrometer dimensions these electrodes possess huge electroactive surface areas; i.e. roughness factors of H<sub>1</sub>-e Pd films were estimated to be typically 300. Hydrogen absorption was shown to be very fast for …
-
Autonomous ocean carbon system observations from gliders
… ocean carbonate system decreasing the seawater pH. To quantify these changes novel sampling and monitoring methods are necessary. One of these methods are gliders. The sensors to fit on a glider need to have a compact size, low-cost, stability, accuracy and fast response. For the first time, a …
-
Microfabricated pH, temperature, and free chlorine sensors for integrated drinking water quality monitoring systems
The monitoring of pH and free chlorine concentration in drinking water is important for water safety and public health. However, existing laboratory-based analytical methods are laborious, inefficient, and costly. This thesis focuses on the development of an easy-to-use, sensitive, and low-cost …
-
Complete systematic study of reactions between copper(II) ions and tripeptides containing glutamic acid, glycine and histidine
… bio-sensors for copper sequestration. Potentiometric pH titration and visible spectroscopy were chosen as the most suitable analytical techniques for this purpose. The experiments provided data on acid dissociation constants (pKa), copper-complex formation constants (logβ), copper …
-
Nanostructured palladium hydride microelectrodes : from the potentiometric mode in SECM to the measure of local pH during carbonation
… with high accuracy and reproducibility of the potentiometric-pH response. In absence of oxygen, the nanostructured palladium hydride tips are sensitive only to the activity of the protons close to their local environment and they have an almost Nernstian theoretical response with a slope of …
-
Nanostructured palladium hydride electrodes: from the potentiometric mode in SECM to the measure of local pH during carbonation
… with high accuracy and reproducibility of the potentiometric-pH response. In absence of oxygen, the nanostructured palladium hydride tips are sensitive only to the activity of the protons close to their local environment and they have an almost Nernstian theoretical response with a slope of …
-
Development and characterization of fluorescent pH sensors based on porous silica and hydrogel support matrices
The hydrogen ion activity (pH) is a very important parameter in environment monitoring, biomedical research and other applications. Optical pH sensors have several advantages over traditional potentiometric pH measurement, such as high sensitivity, no need of constant calibration, easy for …
-
Spectrophotometric determination of pH and its influence in soils
It would be beneficial to develop an alternative pH measurement technique for soils, since the standard glass electrode method suffers deficiencies with unpredictability in liquid junction potential, high drift and the necessity for electrode calibration with variable ionic strength solutions if …
-
Electrolyte-Driven Advances in pH Sensor Development, CO2 Conversion, and Concentrated Electrolyte Modeling
… chapters. Chapter 2 focuses on developing potentiometric solid-state pH sensors. Anodically grown platinum oxide ultramicroelectrodes fabricated under alkaline conditions exhibited a near-Nernstian response and excellent stability in aqueous electrolyte environments, with fast temporal …
-
Preparation of a fibre optic sensor based on AgNp/silica composite for pH measurement
… in a solution, commonly referred to as pH, holds significant importance in various industries. However, measuring pH under high-temperature and high-pressure (HTHP) conditions has posed a formidable challenge due to the lack of reliable sensors and instrumentation. Recent research has …