Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"potentiometric pH"”.

  1. Fully printed potentiometric pH sensor

    … health monitoring and analysis. In particular, pH measurements can be done non-invasively and continuously, making it an excellent parameter for monitoring different stages of wound healing. Here, we report pH sensitivity of a polyaniline/graphite (PANI/G) composite in a fully-printed …

    ets-quebec Download PDF for Fully printed potentiometric pH sensor (opens in a new tab)

  2. Reference Electrode Techniques for Solid State Potentiometric pH Measurement

    … improvement ever made to the conventional potentiometric pH measurement system. This thesis reports on the experimental investigation of several prototype solid state reference electrodes which were designed to eliminate the reliance of conventional potentiometric specific ion glass …

    marquette Repository record for Reference Electrode Techniques for Solid State Potentiometric pH Measurement (opens in a new tab)

  3. Potentiometric pH Measurements in the Pressure Acid Leaching of Nickel Laterites

    … reference electrode has been employed to measure pH of high-temperature acidic sulphate solutions relevant to the pressure acid leaching (PAL) of nickel laterites. In a previous study, this cell was used to measure pH of H2SO4, Al2(SO4)3-H2SO4 and MgSO4-Al2(SO4)3-H2SO4 solutions at 250oC. In this …

    toronto-retro Repository record for Potentiometric pH Measurements in the Pressure Acid Leaching of Nickel Laterites (opens in a new tab)

  4. Investigation and development of titanium nitride solid-state potentiometric pH sensor

    The measurement of pH value is crucial parameter in various fields like, drinking water monitoring, food preparation, biomedical and environmental applications. The most common device for pH sensing is the conventional pH glass electrode. While glass electrodes have several advantages, such as …

    edithcowan Repository record for Investigation and development of titanium nitride solid-state potentiometric pH sensor (opens in a new tab)

  5. Development, manufacture and application of a solid-state pH sensor using ruthenium oxide

    The measurement of pH is undertaken frequently in numerous settings for many applications. The common glass pH probe is almost ideal for measuring pH, and as such, it is used almost ubiquitously. However, glass is not ideal for all applications due to its relatively large size, fragility, need for …

    edithcowan Repository record for Development, manufacture and application of a solid-state pH sensor using ruthenium oxide (opens in a new tab)

  6. Procedures for Assessment of the Marine Carbon System and Evaluation of Access and Ocean Acidification Literacy in the Deaf Community

    … changes in seawater caused by the uptake of atmospheric CO2, especially in coastal environments. Due to the proximity of anthropogenic stressors in the coastal zone, the biogeochemical complexity of the CO2 system is more dynamic than the open ocean. My principal research objectives were addressed …

    usf Repository record for Procedures for Assessment of the Marine Carbon System and Evaluation of Access and Ocean Acidification Literacy in the Deaf Community (opens in a new tab)

  7. Electrochemical microsensor system for cell culture monitoring

    … continuous measurement technique of chemical and physical parameters in cell culture, which impacts many different areas of biological research. With the focus being on eukaryotic cells, many fields such as standardisation of cell culture, cancer research, individualised (cancer) therapy, as well …

    freiburg-diss Repository record for Electrochemical microsensor system for cell culture monitoring (opens in a new tab)

  8. Fabrication and characterisation of nanostructured palladium hydride microelectrode pH sensors

    … created by a hexagonal lyotropic crystalline phase. While retaining micrometer dimensions these electrodes possess huge electroactive surface areas; i.e. roughness factors of H<sub>1</sub>-e Pd films were estimated to be typically 300. Hydrogen absorption was shown to be very fast for …

    soton Download PDF for Fabrication and characterisation of nanostructured palladium hydride microelectrode pH sensors (opens in a new tab)

  9. Autonomous ocean carbon system observations from gliders

    … ocean carbonate system decreasing the seawater pH. To quantify these changes novel sampling and monitoring methods are necessary. One of these methods are gliders. The sensors to fit on a glider need to have a compact size, low-cost, stability, accuracy and fast response. For the first time, a …

    east-anglia Download PDF for Autonomous ocean carbon system observations from gliders (opens in a new tab)

  10. Microfabricated pH, temperature, and free chlorine sensors for integrated drinking water quality monitoring systems

    The monitoring of pH and free chlorine concentration in drinking water is important for water safety and public health. However, existing laboratory-based analytical methods are laborious, inefficient, and costly. This thesis focuses on the development of an easy-to-use, sensitive, and low-cost …

    mcmaster Repository record for Microfabricated pH, temperature, and free chlorine sensors for integrated drinking water quality monitoring systems (opens in a new tab)

  11. Complete systematic study of reactions between copper(II) ions and tripeptides containing glutamic acid, glycine and histidine

    … bio-sensors for copper sequestration. Potentiometric pH titration and visible spectroscopy were chosen as the most suitable analytical techniques for this purpose. The experiments provided data on acid dissociation constants (pKa), copper-complex formation constants (logβ), copper …

    unsw Repository record for Complete systematic study of reactions between copper(II) ions and tripeptides containing glutamic acid, glycine and histidine (opens in a new tab)

  12. Nanostructured palladium hydride microelectrodes : from the potentiometric mode in SECM to the measure of local pH during carbonation

    … with high accuracy and reproducibility of the potentiometric-pH response. In absence of oxygen, the nanostructured palladium hydride tips are sensitive only to the activity of the protons close to their local environment and they have an almost Nernstian theoretical response with a slope of …

    soton Download PDF for Nanostructured palladium hydride microelectrodes : from the potentiometric mode in SECM to the measure of local pH during carbonation (opens in a new tab)

  13. Nanostructured palladium hydride electrodes: from the potentiometric mode in SECM to the measure of local pH during carbonation

    … with high accuracy and reproducibility of the potentiometric-pH response. In absence of oxygen, the nanostructured palladium hydride tips are sensitive only to the activity of the protons close to their local environment and they have an almost Nernstian theoretical response with a slope of …

    soton Download PDF for Nanostructured palladium hydride electrodes: from the potentiometric mode in SECM to the measure of local pH during carbonation (opens in a new tab)

  14. Development and characterization of fluorescent pH sensors based on porous silica and hydrogel support matrices

    The hydrogen ion activity (pH) is a very important parameter in environment monitoring, biomedical research and other applications. Optical pH sensors have several advantages over traditional potentiometric pH measurement, such as high sensitivity, no need of constant calibration, easy for …

    mtu Repository record for Development and characterization of fluorescent pH sensors based on porous silica and hydrogel support matrices (opens in a new tab)

  15. Spectrophotometric determination of pH and its influence in soils

    It would be beneficial to develop an alternative pH measurement technique for soils, since the standard glass electrode method suffers deficiencies with unpredictability in liquid junction potential, high drift and the necessity for electrode calibration with variable ionic strength solutions if …

    adelaide Repository record for Spectrophotometric determination of pH and its influence in soils (opens in a new tab)

  16. Electrolyte-Driven Advances in pH Sensor Development, CO2 Conversion, and Concentrated Electrolyte Modeling

    … chapters. Chapter 2 focuses on developing potentiometric solid-state pH sensors. Anodically grown platinum oxide ultramicroelectrodes fabricated under alkaline conditions exhibited a near-Nernstian response and excellent stability in aqueous electrolyte environments, with fast temporal …

    ku Repository record for Electrolyte-Driven Advances in pH Sensor Development, CO2 Conversion, and Concentrated Electrolyte Modeling (opens in a new tab)

  17. Preparation of a fibre optic sensor based on AgNp/silica composite for pH measurement

    … in a solution, commonly referred to as pH, holds significant importance in various industries. However, measuring pH under high-temperature and high-pressure (HTHP) conditions has posed a formidable challenge due to the lack of reliable sensors and instrumentation. Recent research has …

    strathclyde Repository record for Preparation of a fibre optic sensor based on AgNp/silica composite for pH measurement (opens in a new tab)