Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 322 for “"preconcentration"”.

  1. Membrane-Based Protein Preconcentration Microfluidic Devices

    … devices. I have made membrane-based protein preconcentration systems in capillary and microchip designs to increase the detectability of low-concentration biological samples. A photopolymerized ion-permeable membrane interfaced with a microchannel in poly(methyl methacrylate) (PMMA) formed …

    byu Repository record for Membrane-Based Protein Preconcentration Microfluidic Devices (opens in a new tab) Download PDF for Membrane-Based Protein Preconcentration Microfluidic Devices (opens in a new tab)

  2. Integrated mining and preconcentration systems for nickel sulfide ores

    As part of a strategic research initiative at UBC to design and evaluate integrated underground mining and mineral processing systems, work has been done to determine how to utilize the coarse rejects of pre-concentration in the underground environment. An amenability study for nine orebodies from …

    ubc Repository record for Integrated mining and preconcentration systems for nickel sulfide ores (opens in a new tab) Download PDF for Integrated mining and preconcentration systems for nickel sulfide ores (opens in a new tab)

  3. A Preconcentration Technique For The Determination Of Trace Elements

    A novel preconcentration technique for the determination of trace metal impurities in fine chemicals has been developed. The technique involved forming metal chelates in solution with Chrome Azurol S, and adsorbing them onto powdered activated carbon. Afte r separation by filtration, the enriched …

    plymouth Repository record for A Preconcentration Technique For The Determination Of Trace Elements (opens in a new tab)

  4. In Situ Preconcentration by AC Electrokinetics for Rapid and Sensitive Nanoparticle Detection

    … into lab-on-a-chip devices. Numerical study on preconcentration system design in this work has provided an optimization rule for various biosensor designs using ACEK technique. And the microfluidic immunoassay lab-chip designed based on ACET effect has showed promising prospect for accelerated …

    utk-theses Repository record for In Situ Preconcentration by AC Electrokinetics for Rapid and Sensitive Nanoparticle Detection (opens in a new tab)

  5. A mass spectrometric determination of trace elements in aqueous media without preconcentration

    … to analyze aqueous samples without external preconcentration. Aqueous solutions containing seventy elements were analyzed and the detection limits, sensitivity factors, and linear regression correlation coefficients were determined. A standard test solution of trace elements in water was …

    iastate Repository record for A mass spectrometric determination of trace elements in aqueous media without preconcentration (opens in a new tab)

  6. Metal -Organic Frameworks: Their Microwave Synthesis and Applications as Adsorbents for Preconcentration

    MASS method provides us a simple and fast approach to quickly build a library of other new MOFs. In the third part, we demonstrate the syntheses of 14 new MOF materials based on the MASS method. Each has been tested by TGA to explore its sorption behavior with 4 different vapors. The structures for …

    uiuc Repository record for Metal -Organic Frameworks: Their Microwave Synthesis and Applications as Adsorbents for Preconcentration (opens in a new tab)

  7. Novel preconcentration techniques for the determination of trace metal ions in environmental matrices

    … problem. As a result methods for the selective preconcentration of trace metals are continually investigated. Successful development and application of four novel preconcentration techniques for the determination of trace metal ions are described in the bulk of this thesis. In chapter 1 …

    dcu Download PDF for Novel preconcentration techniques for the determination of trace metal ions in environmental matrices (opens in a new tab)

  8. Microchip capillary electrophoresis: improvements using detection geometry, on-line preconcentration and surface modification

    … performance using detection geometry, on-line preconcentration and surface modification. The first effort to improve detection sensitivity and limits of detection (LODs) of our previous MCE-ECD system is established by an implementation of a capillary expansion (bubble cell) at the detection …

    colostate Repository record for Microchip capillary electrophoresis: improvements using detection geometry, on-line preconcentration and surface modification (opens in a new tab)

  9. SAFEGUARDING WATER RESOURCES: A NOVEL PRECONCENTRATION-BASED COLORIMETRIC APPROACH FOR DETECTING HEAVY METALS

    … their limitations and the requirement for sample preconcentration. Various preconcentration techniques are discussed, emphasizing their performance parameters and advancements in trace-level detection. Furthermore, the thesis identifies the gaps in current technology, particularly in the context …

    mcmaster Repository record for SAFEGUARDING WATER RESOURCES: A NOVEL PRECONCENTRATION-BASED COLORIMETRIC APPROACH FOR DETECTING HEAVY METALS (opens in a new tab)

  10. On-chip preconcentration and infrared detection of toxic volatile organic gases using nanoporous matrices

    … offering a high degree of selectivity. While VOC preconcentration in porous materials can offer sensitivity to an otherwise not very sensitive system, a critical design consideration is multicomponent adsorption-desorption behavior in the choice of porous matrix. For example, polar and non-polar …

    texas Repository record for On-chip preconcentration and infrared detection of toxic volatile organic gases using nanoporous matrices (opens in a new tab)

  11. Synthesis and characterization of short-chain peptides for use in metal remediation and preconcentration

    Designing materials for metal remediation and preconcentration based on naturally occurring metal binding proteins has become of growing interest due to their inherent selective and strong binding, ease of synthesis and available amino acid building blocks, and environmental innocuity. One approach …

    texas Repository record for Synthesis and characterization of short-chain peptides for use in metal remediation and preconcentration (opens in a new tab)

  12. Improved mass spectrometry characterization of organic compounds using analyte preconcentration and radio-frequency ionization.

    … research projects focus on the use of analyte preconcentration and radio-frequency ionization to improve sensitive characterization of organic compounds with MS. A home-built post-column cryogenic trap (PCCT) coupled to a commercial gas chromatography (GC)/quadrupole MS system was utilized for …

    baylor Repository record for Improved mass spectrometry characterization of organic compounds using analyte preconcentration and radio-frequency ionization. (opens in a new tab)

  13. Separation, preconcentration and determination of rare earth elements by inductively coupled plasma emission spectroscopy

    Rare earth elements, (REE), at ug g⁻¹ levels are used for studies of petrogenisis of different geological materials. For these studies, the REE must be determined precisely. An analytical program was established using an IL 200 Inductively Coupled Plasma, (ICP), spectrometer for the determination …

    cape-town Repository record for Separation, preconcentration and determination of rare earth elements by inductively coupled plasma emission spectroscopy (opens in a new tab)

  14. The Investigation of The Electrical Control of Hemimicelles and Admicelles on Gold for Analyte Preconcentration

    … (CMC= 8 mM) on gold surfaces for analyte preconcentration, prior to chromatographic analysis, is presented. Charged ionic surfactants, such as DS, drawn to a surface of opposite charge (porous nickel substrates coated with gold) serve as a stationary phase to trap organic analytes. It is …

    wku-diss Repository record for The Investigation of The Electrical Control of Hemimicelles and Admicelles on Gold for Analyte Preconcentration (opens in a new tab)

  15. Solvent Extraction Preconcentration of Trace Metal Ions from Natural Waters with an Alkylated Oxine Derivative

    <p> A method for the simultaneous preconcentration by solvent extraction of a group of trace metal ions from natural waters has been developed. The procedure makes use of a proprietary "liquid cation-exchanger", Kelex 100, the primary component of which is an alkylated oxine (8-quinolinol) …

    mcmaster Repository record for Solvent Extraction Preconcentration of Trace Metal Ions from Natural Waters with an Alkylated Oxine Derivative (opens in a new tab)

Page 1 of 17