Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 63 for “"premise plumbing"”
-
Pitting Corrosion in Copper Premise Plumbing
Household systems use copper pipe as the plumbing material due to the excellent characteristics of the pipe such as easy installation and low cost. However, copper pipe is subject to corrosion despite being categorized as corrosion resistant. Pitting corrosion of copper pipe has occurred in several …
-
Methylobacterium spp.: Emerging Opportunistic Premise Plumbing Pathogens
Opportunistic premise plumbing pathogens (OPPPs) are responsible for many infections linked to drinking water. The annual cost of disease caused by these waterborne pathogens is $850 million. Key characteristics of these opportunistic waterborne pathogens include: disinfectant- resistant, biofilm …
-
Critical factors controlling regrowth of opportunistic pathogens in premise plumbing
… in human-made water systems, particularly premise plumbing, are now the primary source of water-borne disease in developed countries. The prevention and control of opportunistic pathogens is a new challenge in premise plumbing due to the limited knowledge concerning the factors driving …
-
An investigation of water quality considerations for premise plumbing systems in buildings
… at the distribution system level. However, premise plumbing systems are unique and different from water distribution systems. Moreover, there are knowledge gaps for premise plumbing in residential and non-residential buildings under routine operations, and that has not been fully understood …
-
Microbial Ecology of Acanthamoeba polyphaga and Sulfate-Reducing Bacteria in Premise Plumbing
Great advances have been made in the last 100 years in the effort to provide safe and reliable potable water. Unfortunately, organisms surviving the water treatment process still cause illnesses in the population. Acanthamoebae are ubiquitous in the environment and are resistant to commonly used …
-
Relationship Between Organic Carbon and Opportunistic Pathogens in Simulated Premise Plumbing Systems
… of heterotrophic bacteria and pathogens within premise plumbing. This thesis is the first systematic examination of opportunistic pathogen persistence and amplification in simulated glass water heaters (SGWH) as a function of influent organic matter concentration. The role of plumbing conditions …
-
Practical Impacts of Galvanic Corrosion in Water Service Lines and Premise Plumbing
… use of dielectrics in water service lines and premise plumbing.
-
Drinking Water Microbiome Dynamics within Premise Plumbing and Point-of-Use Filtration Systems
… associated with water quality changes within premise plumbing and at the point of use, indicating a need to better understand the microbiological dynamics of premise plumbing and at the point-of-use.</p> <p>Examining the dynamics of tap water had revealed that overnight stagnation had led to …
-
Nitrification in premise plumbing and its effect on corrosion and water quality degradation
… least some circumstances. Moreover, that certain plumbing materials would inhibit nitrification, but that in other situations the plumbing materials would enhance nitrification. Experiments verified that nitrification could affect the relative efficacy of chlorine versus chloramine in controlling …
-
Microphone-Based Non-Invasive Sensor Module for Waterflow Event Detection in Premise Plumbing Systems
… is the most important consideration of the premise plumbing system design for a new building. It is responsible for governing the size of the water supply system for the building. Due to the outdated design procedures and building codes, the premise plumbing systems of new buildings can be …
-
Linkage Between Characteristics of Premise Plumbing Systems and Microbial Quality of Stagnant Drinking Water
… water main and the point of use (POU), known as premise plumbing, has a direct impact on public health. However, relatively little is known about factors that affect the microbial quality in premise plumbing. Although microbial quality typically degrades during stagnation, little research is …
-
Detection And Identification Of Legionella Bacteria In Premise Plumbing Supplied By Aging Potable Water Infrastructure
… have been associated with buildings with complex premise plumbing systems (e.g., healthcare facilities, hospitals, large buildings) and engineered water systems (e.g., cooling towers, fountains, showers), which have environments optimal for Legionella growth. Furthermore, aging municipal drinking …
-
Effects of Scale Reduction Technologies and Chemical Inhibitors on Calcium Precipitation in Premise Plumbing Systems
Precipitation of solids in plumbing systems (i.e., scaling) is a major problem in both traditional tank (electric and gas) and tank-less building hot water systems. Scaling can cause energy inefficiencies, flow reduction, pressure loss, and erosion corrosion damage. Consumers are also concerned …
-
Two Issues in Premise Plumbing: Contamination Intrusion at Service Line and Choosing Alternative Plumbing Material
… enter into the drinking water as the home plumbing system is a passive recipient from the water main. While the major (municipal) system is readily recognized as a vast infrastructure system of nearly 1,409,800 km of piping within the United States, the minor (plumbing) system that is at …
-
Effect of Various Water Chemistry Factors on Legionella Proliferation and the Premise Plumbing Microbiome Composition
Premise plumbing, the pipes and fixtures at the building level, present a unique challenge for maintaining drinking water quality. Of particular concern are opportunistic pathogens, including Legionella pneumophila which can regrow in premise plumbing and cause disease in immunocompromised …
-
ANALYZING FACTORS WHICH AFFECT LEGIONELLA OCCURRENCE IN A FULL-SCALE GREEN BUILDING PREMISE PLUMBING SYSTEM
… of water conservation practices. However, plumbing design guidance has not been updated to reflect this change, resulting in increased hydraulic retention time, disinfectant decay, and the proliferation of opportunistic premise plumbing pathogens (OPPPs) such as Legionella pneumophila. Time …
-
Factors Contributing to Chlorine Decay and Microbial Presence in Drinking Water Following Stagnation in Premise Plumbing
<p>Premise plumbing is the part of the drinking water distribution system closest to the point of use. Since premise plumbing is characterized by a long residence time, elevated temperature, and reduced levels of disinfectant residue, drinking water in premise plumbing typically experiences …
-
Exploring the Impacts of Microplastics and Nanobubble Disinfection on Drinking Water Biofilms Under Premise Plumbing Conditions
Premise plumbing is a complex and vulnerable drinking water system where various physical, chemical, and biological parameters can undermine water quality and potentially increase human health risks. It is unclear whether contaminants that have been found in drinking water, like microplastics …
-
Dose Determines if Soluble Copper is a Nutrient or an Antimicrobial for Legionella pneumophila in Premise Plumbing
… on Legionella pneumophila in potable water plumbing systems is dependent on its dose and water chemistry. For instance, prior research demonstrated that the presence of aluminum hydroxide from anode rods in water heaters can bind copper and render high doses non-toxic. On this basis it was …
-
Dezincification and Brass Lead Leaching in Premise Plumbing Systems: Effects of Alloy, Physical Conditions and Water Chemistry
… fittings in cross-linked polyethylene (PEX) plumbing systems. As PEX systems gain popularity and leaded brass is recognized as an important source of lead in potable water systems, it is important to examine dezincification corrosion in more detail. An in-depth literature review revealed that …
Page 1 of 4