Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 83 for “"press-fit"”
-
Beeinflussung der Verankerungsstabilität von Press-fit Pfannen durch die Rückflächenkonfiguration
… ist der Vergleich der Verankerungsstabilität von Press-fit Pfannen und einer Press-fit Pfanne, welche mit sechs zusätzlichen radial angeordneten und gebogenen Finnen ausgestattet ist. Methode: Die 4 Pfannentypen (Ana.Nova® Pfanne [Fa. ImplanTec], Allofit® [Fa. Zimmer], Reflection® [Fa. …
-
Initial Stability of Press-fit Acetabular Components in Total Hip Replacements
… understanding of the behaviour of an implanted press-fit cup and the basis for more representative protocol for future pre-clinical evaluations of new design features that can improve cup fixation, and hence its longevity.
-
Press-fit stability of cementless femoral knee implants. A biomechanical evaluation
Radboud University, 27 maart 2017
-
Etude d'un procédé de connectique sans soudure : vieillissement de connectiques type press-fit
… utilisé en connectique automobile type pressfit) est d'une importance capitale. En effet, ces whiskers peuvent générer des courts-circuits entre connecteurs, ce qui affecte la fiabilité de ces systèmes de connectique. Plusieurs paramètres physico-chimiques intrinsèques (épaisseur et type …
-
Evaluation of a press-fit osteochondral poly(ester-urethane) scaffold in a rabbit defect model
… evaluate the impact on osteochondral healing of press-fitted multiphasic osteochondral scaffolds consisting of poly(ester-urethane) and hydroxyapatite into a cylindric osteochondral defect in the distal non-weight bearing femoral trochlear ridge of the rabbit. Two scaffolds were investigated, one …
-
Atténuation de la croissance de whiskers dans des connecteurs électriques Press fit : tests accélérés et conception
… mais à froid par déformation plastique (procédé Pressfit). Les effets de ce procédé sur l’apparition et la croissance de whiskers ont été peu étudiés malgré son utilisation importante dans la fabrication des circuits imprimés. Nous avons travaillé en collaboration avec les sociétés ACS et PEM. …
-
Proximal bone levels of plateau-designed, press fit implants adjacent to a natural teeth and implants.
… bone levels of a single tooth, plateau-designed, press fit implants (Bicon®) utilizing a locking tapered, implant to abutment connection adjacent to a natural teeth and to a plateau design Bicon® implants. The bone levels were evaluated separately for those implants that were closer to a natural …
-
Use of a Press-Fit Grip Sleeve for Cable-In-Conduit Superconductor Integration: Effects of Tensile and Fatigue Loading
… of pulling toroidal field cable with a press-fit grip sleeve that utilizes friction to generate a gripping force. Such a design is being considered by ITER to integrate (join) 800 m long sections of superconducting cable and conduit for use in toroidal field plasma confinement coil …
-
Evaluation of a Press Fit, Percutaneous, Skeletally Anchored Endoprosthesis for Prosthetic Limb Attachment: Bone Response and the Effect of Low Intensity Vibration
… on this bone response. We hypothesized that a press fit between the endoprosthesis and bone would provide stable fixation and that low intensity vibration would improve osseointegration without jeopardizing mechanical stability. To test this hypotheses a press fit, percutaneous endoprosthesis …
-
Investigation of the effect of surgical factors on the transition from primary to secondary stability of press-fit components in the proximal medial tibia
… Knee Replacement (OUKR) is achieved through press-fit. It is a prerequisite for successful secondary stability and is crucial for successful long-term implant survival. The aetiology of tibial periprosthetic fracture (PPF) and tibial component subsidence which are two complications after OUKR …
-
Time-dependent circumferential deformation of cortical bone subjected to internal radial loading
… and has implications to the stability of a press-fit hip implant. Total hip arthroplasty is a surgical procedure to replace the hip joint. It involves inserting an implant into the shaft of the femur. One method of implant fixation is a press-fit of the implant into the bone canal. Press-fit …
-
Interrupted shaft fits
… shafts and components often use interference fits for assembly. Designers use straight and tapered fits. Coupling hubs are a good example. This thesis shows derivations relating press fit force, interference, length, taper, and friction. For simple fits, the Lamé' thick-walled cylinder …
-
Retrograde Ausdrückversuche am bovinen Femurkondylus zur Testung der Implantatverankerung spongiöser Konstrukte
… <br>Das Verfahren der Wahl ist die sogenannte Press-fit Methode. Mittels Press-fit wurden spongiöse Konstrukte verschiedenen Durchmessers und Form in bovinen Femurkondylen verankert und anschliessend deren mechanische Belastbarkeit durch Ausdrückversuche verifiziert. <br>Anschliessend erfolgte …
-
Primärstabilität dentaler Implantate
… Es wurde mit 2 verschiedene Implantatsysteme (press fit-Implantate und Schraubenimplantate) der Fa. Friadent mit gleicher Länge (13 mm) jedoch unterschiedlichen Implantatdurchmessern (3,8 mm, 4,5 mm und 5,5 mm) getestet. Ziel der Untersuchung war es einen Grenzwert für die Primärstabilität …
-
The numerical evaluation of multi-piece crankshafts
… Various simulation models that include press-fit joint contact conditions and complex meshing schemes are examined in order to accurately capture details of the stress fields present at the stress concentration area (labeled as the SCA) on the edge of the press-fit. The maximum stress …
-
The effects of cortical bone viscoelasticity on the fixation/stability of cemented and cementless femoral implants: A finite element analysis.
… evaluate the effects of coefficient of friction, press-fit and bone viscoelasticity on stem fixation. The push-out load increased with µ for each value of δ, but minimal increases in the push-out load (2.9% to 4.9%) were observed for δ > 0.10mm. Bone viscoelasticity reduced the push-out load (2.6% …
-
Sliding Vane Pump Shaft Structural Response and Intermittent Failure Investigation
… to examine the effects of the seal drive pin press fit operation on the pump shaft. Dynamic measurements of the pump discharge and pump chamber pressure were acquired at a high sample rate to study the pressures the pump shaft would be subjected to. Dynamic strain measurements of the pump …
-
Optical Fiber Microstructures for Self-Contained Whispering Gallery Mode Excitation
… the fabrication and function of three new "press fit" spherical resonators. These etched fiber micro-devices were developed to meet the demand for a robust, self-integrated means of coupling light between an optical fiber and WGMs in a microsphere resonator. The etching processes have been …
-
Development of a nano-satellite micro-coupling mechanism with characterization of a shape memory alloy interference joint
… memory alloy (SMA) cylindrical ring that is press-fit, in its detwinned martensitic phase, into a steel bushing, creating an interference joint. This SMA interference joint can subsequently decouple upon command, by heating the SMA cylindrical ring into its smaller austenitic memory shape, …
Page 1 of 5