Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 18 of 18 for “"pressure drop coefficient"”

  1. Diagnosis of Coronary Artery Disease Using Pressure Drop Coefficient

    … parameters e.g. Fractional Flow Reserve (FFR; pressure derived) and Coronary Flow Reserve (CFR; flow derived) with minimal-invasive clinical procedures, which showed a high agreement with non-invasive stress testing. However, an important limitation in using either of the above single modality …

    ohiolink Repository record for Diagnosis of Coronary Artery Disease Using Pressure Drop Coefficient (opens in a new tab)

  2. Diagnostic Accuracy of Pressure-Drop Coefficient (CDP) for Functional Assessment of Coronary Artery Disease using Multicenter International ILIAS Registry Data

    Introduction. Diagnostic parameters such as pressure-based fractional flow reserve (FFR) and flow-based coronary flow reserve (CFR) are used to assess the functional status of intermediate coronary stenosis during cardiac catheterization. However, the complex hemodynamics within stenosis may not be …

    ohiolink Repository record for Diagnostic Accuracy of Pressure-Drop Coefficient (CDP) for Functional Assessment of Coronary Artery Disease using Multicenter International ILIAS Registry Data (opens in a new tab)

  3. Comparison of 5-Year Clinical Outcomes between Pressure Drop Coefficient and Fractional Flow Reserve in Patients with Coronary Artery Disease

    Background: The current pressure-based coronary diagnostic index, fractional flow reserve (FFR), has a limited efficacy in the presence of microvascular disease (MVD). To overcome the limitations of FFR, we recently introduced the pressure drop coefficient (CDP), a fundamental fluid dynamics-based …

    ohiolink Repository record for Comparison of 5-Year Clinical Outcomes between Pressure Drop Coefficient and Fractional Flow Reserve in Patients with Coronary Artery Disease (opens in a new tab)

  4. Thermo-Fluid Effects Associated with Modelling Subscale Automotive Heat Exchangers

    … model scale. Instead they are simply modelled as pressure drops, achieved using a thin mesh or honeycomb of known porosity. Most commercial computational fluid dynamics solvers ignore the geometry of the heat exchanger and instead model it as a discontinuity with a known pressure drop and heat …

    cranfield Repository record for Thermo-Fluid Effects Associated with Modelling Subscale Automotive Heat Exchangers (opens in a new tab)

  5. Influence of geometric and flow variations on coronary diagnostic parameters: An in-vitro study

    … stenosis. These parameters are evaluated from pressure and/or flow information, using sensor-tipped guidewire advanced into an artery at maximal vasodilation (hyperemia) condition. FFR is defined as the ratio of hyperemic pressures distal and proximal to a stenosis. CFR is the ratio of flow at …

    ohiolink Repository record for Influence of geometric and flow variations on coronary diagnostic parameters: An in-vitro study (opens in a new tab)

  6. PREDICTION OF HEAT TRANSFER AND PRESSURE DROP OF CONDENSING REFRIGERANT FLOW IN A HIGH ASPECT RATIO MICRO-CHANNELS

    … 15 oC on the average heat transfer and overall pressure drop coefficient of the micro-channel condenser. In all cases the inlet vapor quality was kept at 100% quality (saturated vapor) and the outlet condition was always kept at 0% quality (saturated liquid). Accuracy of the fabricated channel …

    maryland Repository record for PREDICTION OF HEAT TRANSFER AND PRESSURE DROP OF CONDENSING REFRIGERANT FLOW IN A HIGH ASPECT RATIO MICRO-CHANNELS (opens in a new tab)

  7. The Effects of Fluid Elasticity on Grid Turbulence

    … higher turbulence intensities per unit Cp (pressure drop coefficient) than the classic plain grid, and the turbulence Reynolds number Reλ is increased by a factor of roughly two. In polymer solutions turbulence dissipation rates and energy spectra were measured using PIV with a high spatial …

    epfl Repository record for The Effects of Fluid Elasticity on Grid Turbulence (opens in a new tab)

  8. Effect of Arterial Wall-Stenosis Compliance on Coronary Diagnostic Parameters

    … Flow Reserve (FFR), which is calculated from pressure measurements across stenosed (blocked) arteries, are often used to determine the functional severity of coronary artery stenosis. This study evaluated the effect of arterial wall-stenosis compliance, with limiting scenarios of stenosis …

    ohiolink Repository record for Effect of Arterial Wall-Stenosis Compliance on Coronary Diagnostic Parameters (opens in a new tab)

  9. Gas liquid separation within a novel axial flow cyclone separator

    … which will predict separation efficiency or pressure drop for all designs of cyclone. A novel design of axial flow cyclone called WELLSEP was examined for the purpose of degassing. This design was not believed to be optimal and no design criteria or performance prediction models were …

    cranfield Repository record for Gas liquid separation within a novel axial flow cyclone separator (opens in a new tab)

  10. Effect of coronary collateral flow on diagnostic parameters: An In vitro study

    … severity of blockage, the flow obstruction and pressure variations caused (functional severity). So, functional severity of coronary stenosis is often assessed using diagnostic parameters. These parameters are evaluated from the combined pressure and/or flow measurements taken at the site of the …

    ohiolink Repository record for Effect of coronary collateral flow on diagnostic parameters: An In vitro study (opens in a new tab)

  11. Flow resistance of screen plate apertures

    … resistance was assessed using the nondimensional pressure drop coefficient (K) across the screen plate, and K was studied by three methods. Computational fluid dynamics (CFD) was used to predict how flow variables and aperture geometry affect K in an idealized screening configuration. Experiments …

    ubc Repository record for Flow resistance of screen plate apertures (opens in a new tab)

  12. Efficacy of New Diagnostic Parameters for Determining Arteriovenous Fistula Functionality: A Numerical Study

    … Fistula (AVF) are based on either flow or pressure. These parameters, namely vascular access blood flow rate (Qa) and ratio of venous pressure to arterial pressure (VAPR) have been found to provide an inaccurate estimate of AVF functionality in the presence of a venous stenosis. These …

    ohiolink Repository record for Efficacy of New Diagnostic Parameters for Determining Arteriovenous Fistula Functionality: A Numerical Study (opens in a new tab)

  13. Shaft resistance: The effects of the cages

    … was ascertained end the validity of using the Pressure Drop Coefficient (P.D.C.) was chocked. Interference effects between the cage and buntons had a profound influence on the vane of the cage P.D.C., this effect varying for different types of bunton arrangement. It was shown aloe, that the …

    glasgow Repository record for Shaft resistance: The effects of the cages (opens in a new tab)

  14. Evaluation of Pulmonary Artery Dysfunction in Congenital Heart Disease Patients using Functional-Anatomical Diagnostic Parameters and 4D MRI

    … non-invasively measuring flow (Q) and (derived) pressure drop. However, its current clinical use is limited to flow assessment only. Further, clinical assessment of structural remodeling within the PAs is limited. This research is focused on improving the diagnosis of dysfunctional main, left, …

    ohiolink Repository record for Evaluation of Pulmonary Artery Dysfunction in Congenital Heart Disease Patients using Functional-Anatomical Diagnostic Parameters and 4D MRI (opens in a new tab)

  15. Influence of Serial Coronary Stenoses on Diagnostic Parameters: An <i>In-vitro</i> Study with Numerical Validation

    … fractional flow reserve (FFR: ratio of pressures distal and proximal to a stenosis). The threshold of FFR has a “gray” zone of 0.75-0.80, below which further clinical intervention is recommended. An alternate diagnostic parameter, pressure drop coefficient (CDP: ratio of trans-stenotic …

    ohiolink Repository record for Influence of Serial Coronary Stenoses on Diagnostic Parameters: An <i>In-vitro</i> Study with Numerical Validation (opens in a new tab)

  16. Effects of hemodynamic stresses on the remodeling parameters in arteriovenous fistula

    … is that wall shear stress (WSS), flow, and pressure can be used to predict the remodeling behavior and thus, the functionality of AVFs over time. To test this hypothesis, three specific aims are formulated:1) To assess the longitudinal effects of WSS on the changes in luminal area and …

    ohiolink Repository record for Effects of hemodynamic stresses on the remodeling parameters in arteriovenous fistula (opens in a new tab)

  17. Guidewire Flow Obstruction Effect on Diagnosis of Coronary Lesion Severity: In-Vitro Experimental and Numerical Study

    The transstenotic pressure drop is one of the important basic fluid mechanics parameters used to assess the coronary stenosis severity along with FFR and CFR. Clinically, the transstenotic pressure or pressure drop and flow are measured by inserting a sensor tipped guidewire of diameter 0.014" …

    ohiolink Repository record for Guidewire Flow Obstruction Effect on Diagnosis of Coronary Lesion Severity: In-Vitro Experimental and Numerical Study (opens in a new tab)

  18. Model-based design and control of directed self-assembly of colloidal particles and protein crystallization

    … fewer mixing elements and a substantially lower pressure drop and shear rate. The mixing effects at the entrances and exits of the mixing elements are enhanced by the introduction of gaps between the elements. The performances of Kenics mixers based on the right-left and right-right …

    hkust Repository record for Model-based design and control of directed self-assembly of colloidal particles and protein crystallization (opens in a new tab)