Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 26 for “"pressure modulation"”
-
Reliable experimental setup to test the pressure modulation of Baerveldt Implant tubes for reducing post-operative hypotony
… an increase in the eye’s internal (intraocular) pressure (IOP) above the nominal range of 15 – 20 mm Hg. There are many treatments available for this group of diseases depending on the complexity and stage of nerve degradation. In extreme cases where drugs or laser surgery do not create better …
-
Radiometry of the atmosphere of Mars
… concerned with a project to apply the method of pressure modulation radiometry to measurements of the temperature and water vapour distributions in the atmosphere of Mars. The technique has already been used successfully to measure temperature (and occasionally composition) in the atmospheres of …
-
Design and Validation of a Proportional Throttle Valve System for Liquid-Fuel Active Combustion Control
High-bandwidth fuel modulation is currently one of the most promising methods for active combustion control. To attenuate the large pressure oscillations in the combustion chamber, the fuel is pulsed so that the heat release rate fluctuations damp the pressure oscillations in the combustor. This …
-
Density-Induced Spin-Nematic Squeezing in a Spin-1 Bose-Einstein Condensate
Density or pressure modulation of materials is an important method for tuning and engineering interactions within materials studied in condensed matter systems. This tuning is often used to alter or modify the underlying properties of the material, leading to the crossing of a phase transition or …
-
Characterization of background neutral flows in vacuum test facilities and impacts on hall effect thruster operation
… it has been shown that increases in facility pressure result in artificial increases in device thrust and efficiency due to the ingestion of ambient background neutrals present in the vacuum facility. Although several analytical and semi-empirical models of HET neutral ingestion exist, none …
-
Radiometric measurements of atmospheric temperature
… method of using a cell of carbon dioxide, the pressure of which is periodically modulated, as the spectroscopic element, as suggested by J. T. Houghton and C. D. Rodgers in 1965, is evaluated theoretically and shown to be capable of a temperature discrimination of 1°K with adequate height …
-
A field and Numerical Investigation of the Pressure Pulsing Reagent Delivery Approach
… along paths of least hydraulic resistance. The pressure pulse technology stands among a number of innovative methods that have been developed with the aim of overcoming or mitigating this limitation. The objective of this research was to observe and document differences in saturated groundwater …
-
Optical Cerebral Blood Flow Monitoring of Mice to Men
… Modified Beer-Lambert approach is employed in a pressure modulation scheme, which determines subject-specific contributions of extra-cerebral and cerebral tissues to the DCS/DOS signals by utilizing probe pressure modulation to induce variations in extra-cerebral hemodynamics while cerebral …
-
Investigating the Potential of Sonothermal Modulation in Biomedical Photoacoustic Imaging
… a final image with reduced LAEs. Sonothermal modulation is a technique of inducing small ultrasonic heating spots that locally change the photoacoustic pressure to introduce granularity. In this thesis, simulation toolkits and a prototype test-bed were developed to explore the feasibility of …
-
Optoelectronic, structural, and topological properties of van der Waals layered materials under extreme conditions
… 2D materials, and effects of hydrostatic pressure on 2D and other layered materials. In Chapter 2, we report detailed study on air-degradation of few-layer phosphorene films and field effect transistors, as well as an effective encapsulation method that enhances the stability of devices up …
-
3D Particle Tracking Velocimetry of the Convective Structure in Transient Evaporating Liquid Films
… were subjected to an impulsive superheat via pressure modulation and the development of the resulting convective structure was observed. 2mm films were used for comparison to previous visualization and heat transfer results. Two primary convective structures were observed via 3D-PTV: …
-
Thermodynamics of polymerization, dielectric properties, and a new orientational glass
… studied, as follows. (1) The temperature and pressure modulation effects on structural relaxation have been formulated and simulated. The calculated heat capacity for the modulated conditions shows extra features over that for unmodulated conditions, which may cause misinterpretation of a …
-
Control Of Dry Adhesion Via Mechanics And Structuring
… the dynamic control of adhesion via subsurface pressure modulation was investigated by considering the adhesion of a pillar with an embedded annular chamber that can be pressurized. The location and magnitude of the maximum normal stress at the interface can be tuned by pressurization of the …
-
Carrier Transport Response and Behavior of Semiconductors Having a Gradational Energy Band Gap Due to Gradients in Pressure or Other Physical Properties
… crystal hosting an acoustic wave. Dynamic pressure effects and pressure-induced thermal effects cause two separate transport phenomena in the lattice. First, the conditions under which carriers can be treated as classical particles, and when quantum mechanical phenomena start to play a …
-
Neuromodulation for autonomic disorders
… in multisystem physiological dysfunction. Neuromodulation of the autonomic nervous system has emerged as a potential means of alleviating symptoms in conditions where autonomic dysregulation is either primary or contributory.<br><br>Hypertension remains a leading global cause of morbidity and …
-
Μελέτη των αιμοδυναμικών, ιστολογικών και εργαστηριακών μεταβολών μετά απο εκτεταμένες ηπατεκτομές σε ζωικό πρότυπο
… group A (88.9% vs 44.4%, P<0.05). Portal vein pressure (PVP) and liver function tests in the splenectomy group were significantly lower than in group A immediately after splenectomy and postoperatively until the day of sacrifice. Histological findings in group A clearly illustrate severe …
-
Developing a framework for an adaptive transtibial prosthetic socket using FEA-based tissue injury risk estimation and generalised predictive control
… responsibility of determining safe interface pressure levels solely on the user’s perception. This research entails a set of theoretical studies developing a framework for an automatically adjustable prosthetic socket system enabling estimation of residuum tissue injury risk for safe interface …
-
Investigation of the Mechanical Properties of the Helicobacter pylori Cell Envelope and Maintenance of Helical Shape by Asymmetric Peptidoglycan Synthesis
… length and width changes in response to turgor pressure modulation via osmotic shock are inversely related, with cells becoming longer and narrower after hyper-osmotic shock and shorter and wider after hypo-osmotic shock. In response to hyper-osmotic shock, the major axis appears to be rigid, …
-
Novel pneumatic circuit for the computational control of soft robots
… work. Thirdly, in order to achieve continuous pressure modulation with integrable devices, we designed a soft proportional valve, utilizing the continuous deformation of Magnetorheological Elastomer (MRE) under magnetic flux. Apart from the analogue activation manner, this design also ensures a …
-
Integrating Smart Materials and Adhesion Mechanics for Soft Gripping Mechanisms
… its dry adhesion strength with varied pneumatic pressure. The dry adhesion is tuned in all the approaches because the stress distribution at the adhered interface is altered. For the latter two approaches, dynamic dry adhesion tuning is achieved, either through subsurface stiffness modulation …
Page 1 of 2