Results 1 to 20 of 362 for “"pressure-volume"”
-
Miniature Implantable Telemetry System for Pressure-Volume Cardiac Monitoring
… Currently, no fully implantable left-ventricle pressure--volume (PV) telemetry systems have been implemented for Safety Pharmacology assessment applications. A fully implantable PV telemetry system would not only allow safety pharmacologists to better determine a drugs effect on the heart over …
-
Mathematical Modelling of Brain Haemodynamics and Pressure-Volume Compensation
… which requires an accurate understanding of pressure-volume interactions inside the cranium. This thesis used a hydrodynamic model representing the circulation of cerebral fluids to investigate the relationships between intracranial pressure (ICP) and cerebral blood volume (CBV) changes. The …
-
Pressure-volume-temperature-composition properties of complex spherical molecules
… the studies have been restricted to the low pressure region. The temperature and pressure dependence of the excess volume is particularly useful information. In practice there is no convenient method for measuring the pressure derivative of the excess Gibbs free energy other than that of …
-
Pressure, volume, temperature, and density relations in the critical region. --.
… Studies of the critical temperature-critical pressure region, where the two phases interchange, have been most fruitful in obtaining data on the nature of the differences between them. [...] Dynamic structure hypotheses have been satisfactory in explaining many of the critical phenomena. Among …
-
The Pressure-Volume Relationship and Hysteresis Loss in Stirling Refrigerators
… consist of several spaces in which a volume of gas undergoes expansion and compression. This is also known as a ‘gas spring’. In such a space, heat transfer occurs due to the cyclic temperature difference between the working gas and the adjacent walls. This causes cyclic heat …
-
Non-pharmacological heart failure therapies : evaluation by ventricular pressure-volume loops
… therapy were investigated by left ventricular pressure-volume loop analyses. We demonstrated that restrictive mitral annuloplasty effectively restored mitral leaflet coaptation without inducing significant acute changes in ventricular function. This indicates that this procedure can be safely …
-
The pressure, volume, and temperature behavior of water at negative pressures
… Many workers thus investigated pure gases to pressures of 7,000 psi (22). Others have measured the p-v-T behavior of pure liquids to 150,000 psi (4). It has been known for many years that a liquid column will sustain large tensile stresses (2, 7, 30, 33). Several investigators have made …
-
A neurogenic component in the capacitance vessel pressure-volume response of the dog
This document only includes an excerpt of the corresponding thesis or dissertation. To request a digital scan of the full text, please contact the Ruth Lilly Medical Library's Interlibrary Loan Department (rlmlill@iu.edu).
-
The pressure, volume, and temperature behavior of liquid n-Dodecane at negative pressures
… under suitable conditions, to occupy a larger volume than that associated with equilibrium, The pressure on the liquid is then less than the vapor pressure and often less than zero. However, a liquid subjected to negative pressure is metastable; in time it will change spontaneously to a two …
-
Pressure, volume, temperature, and composition properties of liquid n-alkane mixtures at elevated pressures
… coefficients, latent heat of vaporization, vapor pressure, and vapor-liquid equilibrium in mixtures. To date it has not been found. One attempt to write a specific equation of state has been made for chlorodifluoromethane (36), for example, to densities up to 2.3 times the critical density. This …
-
Development of an implantable system to measure the pressure-volume relationship in ambulatory rodent hearts
… testing of an implantable device to measure the pressure-volume (PV) relationship in the hearts of conscious, untethered rats is presented. Volume is measured using a tetrapolar catheter positioned in the left-ventricle which emits a 20kHz current field across the LV blood pool and parallel heart …
-
The pressure-volume-temperature behavior and the effect of pressure on crystallization kinetics of polyethylene resins /
… by several parameters, in particular the pressure and the temperature history during solidification. Therefore, the study of the influence of pressure and temperature on crystallization kinetics is important. In this study, the crystallization kinetics and the PVT behavior of various …
-
Pressure, volume and flow: studies of ventricular, valvular and vascular haemodynamics in the human cardiovascular system
BACKGROUND: Pressure, volume and flow form the three pillars of quantification in cardiovascular physiology. Newer approaches to their assessment provide opportunities to further assess their interactions. METHODS: 4 projects were conducted. Project 1 evaluated mechanisms of myocardial oxygen …