Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 16 of 16 for “"pressurized sample infusion"”.
-
Reaction monitoring using real-time methods
… in low concentration. When coupled with the pressurized sample infusion (PSI) that helps to continuously inject reacting solution to the MS, both an inert-gas atmosphere and real-time reaction monitoring can be achieved. Also collision induced dissociation (CID) of MS can be used to probe the …
-
Charge-tagging synthetic methodologies for mass spectrometric analysis of complex systems
… Through real-time reaction monitoring with pressurized sample infusion, kinetic and dynamic behaviour of reaction byproducts and intermediates is revealed, along with an investigation of catalyst decomposition and the incidence of alkene isomerization. Chapter 3 presents the synthesis of a …
-
Development of real-time mechanistic tools for the elucidation of catalytic reaction mechanisms
… a phosphine catalyst was investigated using pressurized sample infusion electrospray ionization mass spectrometry (PSI-ESI-MS) and proton and phosphorus nuclear magnetic resonance (NMR) experiments. Since ESI-MS only detects charged species, and only the phosphonium intermediates and …
-
Selective analysis of petroleum fractions by mass spectrometry
… detection of phenols in petroleum fractions. Pressurized sample infusion (PSI) was optimized and used for time dependent analyses. PSI ESI-MS was applied to measure O-alkylation of the phenol species leading to rate information about the overall reaction along with dynamic information about …
-
Real-time Investigation of Catalytic Reaction Mechanisms by Mass Spectrometry and Infrared Spectroscopy
… concentration intermediates within reactions. Pressurized sample infusion (PSI) was used for continuous sample infusion into the mass spectrometer, granting the air-free conditions necessary for these reactions to be successful, and resulting in reaction profile data that contains information …
-
Model compounds for monitoring surface reactivity in the gas phase
… mass spectrometry (ESI-MS) coupled with a sample acquisition technique called pressurized sample infusion (PSI). These techniques were chosen because of their ability to handle highly air- and moisture-sensitive compounds as well as their ability to acquire data in real time. In order for …
-
Mechanistic investigation of catalytic organometallic reactions using ESI MS
… oxygen-sensitive reactions in real time named pressurized sample infusion (PSI) was developed, optimized and applied throughout all the projects in the thesis. These techniques were applied to detailed studies of the intramolecular Pauson-Khand reaction (PKR) with Co2CO8 under different …
-
Mechanistic investigations of palladium-catalyzed cross-coupling reactions using advanced mass spectrometric methodologies
… ionization mass spectrometry (ESI-MS) and pressurized sample infusion (PSI), highlighting their advantages and challenges in capturing transient catalytic species. Chapter 2 discusses the inherent limitations of MS in characterizing high molecular weight polymers, a common product of PdCC …
-
Analytical techniques for reaction monitoring, mechanistic investigations, and metal complex discovery
… as well as active intermediate speciation. Pressurized Sample Infusion-Mass Spectrometry (PSI-ESI-MS), ion mobility-mass spectrometry (IMS-MS), and Nuclear Magnetic Resonance (NMR) spectroscopy are powerful analytical techniques capable of reaction monitoring. Contamination from vulcanized …
-
Real-time analysis of ring closing metathesis reactions
… and the real-time aspect was enabled by using pressurized sample infusion (PSI). Observation of the reactants and products was enabled using charge-tagged bis-alkenes of the general formula [Bu2N{(CH2)nCH=CH2}2]+ [PF6]–. These were synthesized in two steps using a generally applicable …
-
Monitoring complex reactions using tandem mass spectrometric methods
… to monitor the SPC in positive ion mode using pressurized sample infusion (PSI) in real time. Full scan, selected ion recording (SIR), product ion scan, neutral loss scan (NLS) and multiple reaction monitoring (MRM) MS/MS methods were applied. Tetrakistriphenylphosphine palladium(0) was the …
-
New methodology for probing catalytic reactions by ESI-MS
… bis(triphenylphosphine)iminium cation. A new sample introduction method named PSI (pressurized sample infusion) was developed for the continuous infusion of air/moisture-sensitive samples into the mass spectrometer. The flow rate can be determined using a modified version of the …
-
Automation of reaction monitoring
… oxo-titanium reaction. This was made possible by Pressurized Sample Infusion Electrospray Ionization Mass Spectrometry (PSI-ESI-MS) coupled with a smartphone colorimetry technique developed herein known as ColorPixel. In Chapter 3 we explore the integration of machine learning with reaction …
-
Mechanistic insight into homogeneous catalytic reactions by ESI-MS
… homogeneous catalysis study. A method named PSI (pressurized sample infusion) was developed to introduce the air and moisture sensitive reaction mixtures to the ESI-MS. The analytical aspects of the method were investigated and optimized. Applicability of the technique was demonstrated through …
-
Mechanistic investigation of the effect of S-based poisons on Pd-catalyzed cross-coupling reactions
… the catalyst poisoning behavior. In this work, pressurized sample infusion - electrospray ionization - mass spectrometry (PSI-ESI-MS) was used to introduce a poison into a reaction flask containing a Pd cross-coupling reaction solution, which was monitored in real-time. The combination of …
-
Real-time mass spectrometric analysis of catalytic reaction mechanisms
Mass spectrometry was used to study two disparate transformations: in an applied project, the supposed degradation of perfluorooctanesulfonate (PFOS); and in a fundamental study, the Suzuki-Miyaura (SM) reaction was investigated in detail. The first investigation revealed that published methods to …