Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 43 for “"prestressed girders"”
-
End zone design for Alabama deep prestressed girders
Deep prestressed concrete bridge girders are becoming increasingly popular due to their ability to span longer distances and reduce the total cost of bridge projects. However, these girders have frequently been subject to end zone cracking during the transfer of prestress forces despite being …
-
Longitudinal Crack Analysis in Concrete Prestressed Girders: Justification and Implementation
… the integrity of a composite deck pretensioned/prestressed bridge girder after horizontal cracks were discovered at the web-flange interface. This study was accomplished by installing strain gages on an AASHTO Type III girder, obtaining variable loading values, and analyzing the results. Results …
-
PREDICTION OF CAMBER IN PRESTRESSED GIRDERS USING FINITE ELEMENT METHODS.
Abstract not available
-
End-Region Evaluation of Hybrid Ultra-High-Performance Concrete/Conventional Concrete Prestressed Girders
In prestressed concrete girders, the end-regions are often susceptible to high internal forces induced by prestressing, resulting in crack propagation. Resisting these forces necessitates a substantial amount of reinforcing steel, leading to complicated design and congested formwork. Despite this …
-
Design and Behavior of Precast, Prestressed Girders Made Continuous — An Analytical and Experimental Study
… have recognized the benefits of making precast, prestressed multi-girder bridges continuous by connecting the girders with a continuity diaphragm. Although there is widespread agreement on the benefits of continuous construction, there has not been as much agreement on either the methods used for …
-
Bridge Instrumentation and the Development of Non-Destructive and Destructive Techniques Used to Estimate Residual Tendon Stress in Prestressed Girders
… determining the residual prestress force of prestressed concrete bridge girders. For bridges that have yet to be constructed, outfitting girders with instrumentation is a highly effective means of determining residual prestress force in prestressed concrete bridge girders. This constitutes …
-
Investigation of Transfer Length, Development Length, Flexural Strength and Prestress Loss Trend in Fully Bonded High Strength Lightweight Prestressed Girders
… of high performance normal weight composite girders, Virginia Department of Transportation has sought to exploit the use of high strength lightweight composite concrete (HSLWC) girders to achieve economies brought about by the reduction of dead loads in bridges. Transfer Length measurements …
-
Experimental investigation of prestressed Tx-girders with high strength shear reinforcement
… focuses on evaluating the shear behavior of prestressed I-girders reinforced with high-strength steel stirrups in comparison to conventional Grade 60 reinforcement. Four full-scale Tx-62 prestressed girders were tested at the Ferguson Structural Engineering Laboratory. Each girder was tested …
-
FIELD TEST AND ANALYSIS OF TWO PRESTRESSED CONCRETE BRIDGES AFTER DECK REPLACEMENT WITH FRP PANELS
… fifty years. They are short span bridges with prestressed concrete girders. Until late 2001, they had conventional reinforced concrete decks, which have been replaced with fiber reinforced polymer (FRP) decks. Two girders in bridge B-0171 were replaced with new prestressed girders. These …
-
Structural Evaluation of Prestressed Self-Consolidating Concrete Bridge Girders Using Limestone Aggregates
… concrete (SCC) using limestone aggregates for prestressed girder applications. To fulfill the objective of this research, three full-scale prestressed girders were fabricated and tested to evaluate transfer length, prestress losses, camber, flexural behavior and strength, flexural rigidity, and …
-
Threaded rod continuity system for precast prestressed girder bridges
… recalls the earlier research on Precast Prestressed Girders Continuity System done at the University of Nebraska and introduces a new design detail by placing Threaded Rod (TR) above the girder top flange. The new TR continuity system has all the advantages of post-tensioning continuity …
-
COLUMN LOAD BALANCING IN PRESTRESSED CONCRETE BUILDING
… in axial loads. The cable profiles in the prestressed girders are designed not only for moment balancing but also to transfer evenly the shearing forces in the girders to the twin columns in each cluster. The influence and the analysis of the load distribution in successive floors due to …
-
Shear Behavior of Prestressed Concrete Girders and Structural Health monitoring using Fiber Bragg Grating Sensors
This research deals with six Prestressed girders that were tested to observe the shear behavior and investigate the failure mode. Three of the girders had a top slab of eight inches and were constructed with TXDOT specifications. The other three were constructed without the top slab with AASHTO …
-
A Compilation of Research on Self-Consolidating Concrete for Prestressed Bridge Girders
… can be utilized to improve fabrication of prestressed girders. SCC has been used in the precast industry with a satisfactory performance. This was achieved by reducing fabrication time, decreasing health hazards due to excessive noise, and a much better finishing on the surface of the …
-
Computational modeling of prestress transfer, end-region cracks and shear behavior in prestressed concrete I-girders employing large-diameter strands
Prestressed concrete girders are commonly fabricated with 0.5-in. (12.7-mm) or 0.6-in. (15.2-mm) diameter prestressing strands. Recent interest in the use of larger (0.7-in. (17.8-mm) diameter) strands has been driven by potential benefits associated with reduction of the required number of strands …
-
Effect of strand debonding on end cracking in pre-tensioned concrete beams
… of strand debonding. 24 small-scale prestressed concrete beam units were tested and used for the calibration of nonlinear finite element models simulating concrete-strand bond behavior, while two models of AASHTO box girders were established to investigate an incident of end cracking …
-
3D Printing for Prestressed Concrete
… production in the world are on precast and prestressed girders. These girders are used in bridges, buildings and other structural systems. This necessitates a broadened focus to include 3D printing technology for the prestressed industry.To mitigate this gap, this research has taken the …
-
Adaptation of prestressed concrete to modular girder bridge design for advanced base construction
The design of a series of precast prestressed concrete bridges for Naval advanced base construction is presented in this thesis. Girder type concrete bridges composed of modular prestressed girders of I).0, 60, 80, 100 and 120 foot spans have been conceived, in so far as possible, to reduce the …
-
Shear Strength of Full-Scale Prestressed Lightweight Concrete Girders with Composite Decks
… there were twelve tests on six full-scale, prestressed girders with composite decks designed to provide answers to some of those uncertainties. The variables considered were concrete density, concrete compressive strength, effective shear depth, shear span-to-effective depth ratio, the …
-
Shear stress evaluation and limits for the prestressed concrete girders end region
… of various types of pretensioned concrete girders. The proposed analytical models account for differences in geometry and boundary conditions across girder types. The research comprises experimental testing, finite element analysis, database analysis, and analytical evaluations of shear …
Page 1 of 3