Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 39 for “"prestressing strand"”.

  1. Development length of prestressing strand

    … Code Requirements on development length of prestressing strands, a major experimental research on bond development of seven-wire prestresssing strands was conducted. Twenty-two full-scale AASHTO Type-I prestressed concrete bridge beams were tested for transfer length and strand end slip at …

    utk-theses Repository record for Development length of prestressing strand (opens in a new tab)

  2. Grade 300 Prestressing Strand and the Effect of Vertical Casting Position

    … was to investigate the influence an increase in strand strength and the effect the as-cast vertical location had on transfer length, development length, and flexural strength and to resolve the discrepancies regarding the definition of the top-bar/strand effect. Two types of test specimens were …

    vt Repository record for Grade 300 Prestressing Strand and the Effect of Vertical Casting Position (opens in a new tab)

  3. An investigation of the variables affecting pullout of seven-wire prestressing strand

    <p>The pullout strength of untensioned prestressing strand is a function of several variables. This study is an attempt to identify and isolate these variables. Reviews of the existing studies of pretensioned and untensioned strand as well as the pullout testing of larger size untensioned strands …

    ut-knoxville Repository record for An investigation of the variables affecting pullout of seven-wire prestressing strand (opens in a new tab)

  4. A Test Method for the Transfer Length of Prestressing Strand in Hollow Core Slabs

    A method for measuring the transfer length of prestressing strand in HCS using a distributed strain sensor (DSS) was proposed. This DSS consists of a strip of material with strain gauges pre-attached to it. The DSS can then be attached to the HCS to measure strain when the strands are released. A …

    umn Repository record for A Test Method for the Transfer Length of Prestressing Strand in Hollow Core Slabs (opens in a new tab)

  5. Flexural Fatigue Behaviour of Corroded Pretensioned Beams and Their Repair Using Carbon Fibre Reinforced Polymer Sheets

    … under monotonic and cyclic axial loading, full strand testing, and corrosion measurements of prestressing strands corroded while embedded in concrete prism. Material testing achieved multiple objectives: (a) it identified the rate of accelerated corrosion of the prestressing strands, (b) it …

    waterloo Repository record for Flexural Fatigue Behaviour of Corroded Pretensioned Beams and Their Repair Using Carbon Fibre Reinforced Polymer Sheets (opens in a new tab)

  6. Investigation of high strength stainless steel prestressing strands

    … program of high-strength stainless steel (HSSS) prestressing strand to be used in prestressed marine bridge piles. The metallurgy for two types of HSSS strand was selected from a previous study of the corrosion resistance, mechanical properties, and feasibility of 6 candidate HSSS drawn wire …

    gatech Repository record for Investigation of high strength stainless steel prestressing strands (opens in a new tab)

  7. Statistical evaluation of transfer and development length of low-relaxation prestressing strands in standard I-shaped pretensioned concrete beams

    … a moratorium on the use of 0.6-inch diameter prestressing strand for pretensioned concrete beams in October of 1988. This moratorium was imposed because of some apparent unconservatism in the code requirements addressing transfer and development lengths of seven-wire prestressing strand. The …

    ttu Repository record for Statistical evaluation of transfer and development length of low-relaxation prestressing strands in standard I-shaped pretensioned concrete beams (opens in a new tab)

  8. Bond Performance of High-Capacity Strands in High Strength Concrete

    <p>18-mm-diameter (0.7-in.) strand has the ability to introduce almost twice the prestressing force of 13-mm-diameter (0.5-in.) strand and 135% of the prestressing force of 15-mm-diameter (0.6-in.) strand, which could result in a significant increase in the span capacity of the current AASHTO bulb …

    utk-theses Repository record for Bond Performance of High-Capacity Strands in High Strength Concrete (opens in a new tab)

  9. Evaluation of Hybrid-Composite Beam for Use in Tide Mill Bridge

    … The beam consists of a concrete arch tied with prestressing strand that is placed within a Fiber-Reinforced Polymer (FRP) box. Behavior in individual HCB's and a three HCB-system was examined to determine the appropriateness of the current design methodology developed by John Hillman and the …

    vt Repository record for Evaluation of Hybrid-Composite Beam for Use in Tide Mill Bridge (opens in a new tab)

  10. Consideration of strand fatigue for load rating prestressed concrete bridges

    … is an investigation of the use of fatigue of the strand in prestressed concrete beams for the load rating of prestressed concrete bridges. The criteria for load rating prestressed concrete bridges are provided by the American Association of State Highway and Transportation Officials in the Manual …

    texas Repository record for Consideration of strand fatigue for load rating prestressed concrete bridges (opens in a new tab)

  11. The effects of integrated exposed strands on the behavior of prestressed concrete piles in integral abutments

    … design of the integral abutments called for the prestressing strands to be cut along the top of the pile. The integration of the pile into the abutment was achieved by pouring the abutment around a length of the pile. This practice has been replaced. The current practice is to leave the …

    ut-knoxville Repository record for The effects of integrated exposed strands on the behavior of prestressed concrete piles in integral abutments (opens in a new tab)

  12. Bond and Material Properties of Grade 270 and Grade 300 Prestressing Strands

    … material properties of grade 270 and grade 300 prestressing strand of various sizes. Tension tests were performed on each type of strand. The data from these tests was used to determine modulus of elasticity, yield stress, ultimate stress, and ultimate elongation for each strand. The yield …

    vt Repository record for Bond and Material Properties of Grade 270 and Grade 300 Prestressing Strands (opens in a new tab)

  13. Pretest 3-D finite element analysis of the girder-to-cap-beam connection of an inverted-tee cap beam designed for seismic loadings

    … A new connection detail utilizing an unstressed, prestressing strand placed through the girders was then modeled and proposed to provide a moment resistant connection and allow a plastic hinge to form in the top of the column. By allowing a plastic hinge to form in the top of the column the system …

    iastate Repository record for Pretest 3-D finite element analysis of the girder-to-cap-beam connection of an inverted-tee cap beam designed for seismic loadings (opens in a new tab)

  14. Nondestructive testing of reinforced and prestressed concrete structures using acoustic waveguides

    … involves the measurement of tensile forces in a prestressing strand in prestressed concrete structures using ultrasonic stress waves. The commonly used 1/2-inch diameter seven-wire prestressing strands are studied. In this study, both experimental measurements and theoretical analysis are …

    wvu Repository record for Nondestructive testing of reinforced and prestressed concrete structures using acoustic waveguides (opens in a new tab)

  15. Development of Improved Connection Details for Voided Slab Bridges

    … joint, where it corrodes the reinforcement and prestressing strand. Ultimately, the failed keys lead to costly repairs and bridge replacements sooner than their proposed lifespan. This research project aimed to develop a more durable longitudinal connection detail by using sub-assemblages to …

    vt Repository record for Development of Improved Connection Details for Voided Slab Bridges (opens in a new tab)

  16. Anchorage of stirrups in prestressed concrete I-girders

    … are oriented parallel to the longitudinal prestressing strands and are not bent around any longitudinal bars. Such detailing does not meet the specifications in the Canadian Highway Bridge Design Code CSA S6-06. An experimental investigation was conducted on full-scale partial sections of a …

    ubc Repository record for Anchorage of stirrups in prestressed concrete I-girders (opens in a new tab) Download PDF for Anchorage of stirrups in prestressed concrete I-girders (opens in a new tab)

Page 1 of 2