Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 82 for “"prestressing strands"”.

  1. Investigation of high strength stainless steel prestressing strands

    … program of high-strength stainless steel (HSSS) prestressing strand to be used in prestressed marine bridge piles. The metallurgy for two types of HSSS strand was selected from a previous study of the corrosion resistance, mechanical properties, and feasibility of 6 candidate HSSS drawn wire …

    gatech Repository record for Investigation of high strength stainless steel prestressing strands (opens in a new tab)

  2. Investigating the Bond of Prestressing Strands in Lightweight Self-Consolidating Concrete

    … behavior provides the benefits of both. Bond of prestressing steel has been a much debated topic since the 1950s. Limited data are available on the transfer and development length of strands cast in SCC and even less for strands cast in LWSCC. The differences in material properties resulting from …

    arkansas Repository record for Investigating the Bond of Prestressing Strands in Lightweight Self-Consolidating Concrete (opens in a new tab)

  3. Effect of partial debonding of prestressing strands on beam end cracking

    The use of shielded, or debonded, strands is an effective technique to reduce high tensile stresses in the end region of prestressed concrete members. However, damage in the ends of prestressed beams with shielded strands has been increasingly experienced during strand detensioning. Guidelines on …

    msu Repository record for Effect of partial debonding of prestressing strands on beam end cracking (opens in a new tab)

  4. Determining Slipping Stress of Prestressing Strands In Piles Embedded In Cip Caps

    … significantly affected by the slipping stress of prestressing strands. In general the ACI 318 Eqn. (12-4) is used to calculate the development length and slipping stress of prestressing strands, yet the validity of this equation for strands in confined sections is not proven. The piles used were …

    south-carolina Repository record for Determining Slipping Stress of Prestressing Strands In Piles Embedded In Cip Caps (opens in a new tab)

  5. Bond and Material Properties of Grade 270 and Grade 300 Prestressing Strands

    … material properties of grade 270 and grade 300 prestressing strand of various sizes. Tension tests were performed on each type of strand. The data from these tests was used to determine modulus of elasticity, yield stress, ultimate stress, and ultimate elongation for each strand. The yield …

    vt Repository record for Bond and Material Properties of Grade 270 and Grade 300 Prestressing Strands (opens in a new tab)

  6. End-region behavior of precast, prestressed concrete I-girders employing 0.7-inch diameter prestressing strands

    … fabricated using 0.5- or 0.6-in. diameter prestressing strands. In recent years, however, it has become of interest to employ larger-diameter 0.7-in. diameter strands to reduce the number of strands and improve the efficiency of pretensioned concrete members. Such a transition requires a …

    texas Repository record for End-region behavior of precast, prestressed concrete I-girders employing 0.7-inch diameter prestressing strands (opens in a new tab)

  7. Two integral girder connections for precast concrete bridges in seismic regions utilizing extended prestressing strands

    … designed utilizing extended girder prestressed strands. The connections were designed to resist positive moments at the girder to cap connection. Positive moments occur at the connection when seismic forces cause upward deflection of the precast girders resulting in tension forces along the …

    iastate Repository record for Two integral girder connections for precast concrete bridges in seismic regions utilizing extended prestressing strands (opens in a new tab)

  8. Performance of precast, prestressed concrete I-girders employing 0.7-in. diameter prestressing strands under shear-critical loading conditions

    … fabricated using 0.5- or 0.6-in. diameter prestressing strands. However, in recent years, potential benefits such as reduced fabrication costs and extended span capabilities have led to an interest in using larger-diameter 0.7-in. strands in the pretensioning industry. Such an increase in …

    texas Repository record for Performance of precast, prestressed concrete I-girders employing 0.7-in. diameter prestressing strands under shear-critical loading conditions (opens in a new tab)

  9. Statistical evaluation of transfer and development length of low-relaxation prestressing strands in standard I-shaped pretensioned concrete beams

    … a moratorium on the use of 0.6-inch diameter prestressing strand for pretensioned concrete beams in October of 1988. This moratorium was imposed because of some apparent unconservatism in the code requirements addressing transfer and development lengths of seven-wire prestressing strand. The …

    ttu Repository record for Statistical evaluation of transfer and development length of low-relaxation prestressing strands in standard I-shaped pretensioned concrete beams (opens in a new tab)

  10. Material Properties of the Grade 300 and Grade 270 Prestressing Strands and their Impact on the Design of Bridges

    … properties of the new Grade 300, low-relaxation prestressing strand. The purpose of this testing was to verify the advertised breaking strengths and relaxation properties of the Grade 300 strand. Additional properties, such as yield strength, modulus of elasticity, and elongation, were also …

    vt Repository record for Material Properties of the Grade 300 and Grade 270 Prestressing Strands and their Impact on the Design of Bridges (opens in a new tab)

  11. Measurement of Transfer and Development Lengths of 0.7 in. Strands on Pretensioned Concrete Elements

    … in. (17.8 mm), Grade 270 (1860), low-relaxation prestressing strands in construction is slow regardless of its advantages over the use of 0.6 in. (15.2 mm) and 0.5 in. (12.7 mm) strands. The limited research data and unavailable design guidelines partially account for the slow utilization. This …

    arkansas Repository record for Measurement of Transfer and Development Lengths of 0.7 in. Strands on Pretensioned Concrete Elements (opens in a new tab)

  12. Effect of rotational stiffness on the behavior of integral abutments on prestressed concrete piles

    … curves. The effect of leaving the pile's prestressing strands protruding in the abutment versus cutting them flush with the top of the pile was an important comparison. Abutments that lacked prestressing strands had larger cracks at the pile-abutment interface. Even though abutments that …

    ut-knoxville Repository record for Effect of rotational stiffness on the behavior of integral abutments on prestressed concrete piles (opens in a new tab)

  13. Seismic Retrofit of Reinforced Concrete Frames with Diagonal Prestressing Cables

    … which involves diagonal bracing of frames with prestressing strands. An experimental research project has been conducted to assess the effectiveness of diagonal prestressing in non-ductile reinforced concrete frame buildings. The experimental program consists of two large-scale single-bay …

    ottawa-retro Repository record for Seismic Retrofit of Reinforced Concrete Frames with Diagonal Prestressing Cables (opens in a new tab)

  14. Field and laboratory performance of prestressed high performance concrete girders for Missouri bridge structures

    … MPa (10,152 psi) and 15.2 mm (0.6 in.) diameter prestressing strands. HPC materials for both girders and cast-in-place deck were studied for both mechanical and material properties."--Abstract, page iii."

    must-thes Repository record for Field and laboratory performance of prestressed high performance concrete girders for Missouri bridge structures (opens in a new tab)

  15. Repair of Impact-Damaged Prestressed Bridge Girders Using Strand Splices and Fabric Reinforced Cementitious Matrix

    … an impact-damaged girder when up to 10% of the prestressing strands are severed. Combined repairs can also be a viable option if more than 10% of the prestressing strands are severed, though as the damage gets more severe, girder replacement becomes a more attractive option.

    vt Repository record for Repair of Impact-Damaged Prestressed Bridge Girders Using Strand Splices and Fabric Reinforced Cementitious Matrix (opens in a new tab)

  16. Calcium Sulfoaluminate Cement Concrete for Prestressed Bridge Girders: Prestressing Losses, Bond, and Strength Behavior

    … the required 4300 psi needed in order to cut the prestressing strands 6.5 hours after casting. Prestress losses were monitored long-term using vibrating wire strain gages cast into the concrete at the level of the prestressing strands and the data was compared to the American Association of State …

    utahstate Repository record for Calcium Sulfoaluminate Cement Concrete for Prestressed Bridge Girders: Prestressing Losses, Bond, and Strength Behavior (opens in a new tab)

  17. Experiments on a Hybrid Composite Beam for Bridge Applications

    … (FRP) shell with a concrete arch tied with steel prestressing strands. The HCB offers advantages in life cycle costs through reduced transportation weight and increased corrosion resistance. By better understanding the system behavior, the proportion of load in each component can be determined, …

    vt Repository record for Experiments on a Hybrid Composite Beam for Bridge Applications (opens in a new tab)

  18. Load Testing Deteriorated Spans of the Hampton Roads Bridge-Tunnel for Load Rating Recommendations

    … carrying girders. Concrete spalling has exposed prestressing strands within the girders allowing corrosion to spread. Some of the more damaged girders have prestressing strands that have completely severed due to the extensive corrosion. The deterioration has caused select girders to fail the …

    vt Repository record for Load Testing Deteriorated Spans of the Hampton Roads Bridge-Tunnel for Load Rating Recommendations (opens in a new tab)

Page 1 of 5