Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"primary airflow"”.

  1. Modeling of Electronically Commutated Motor Controlled Fan-powered Terminal Units

    Empirical models of airflow and power consumption were developed for series and parallel variable air volume fan powered terminal units (FPTUs). An experimental setup and test procedure were developed to test the terminal units over typical operating ranges. The terminal units in this study used …

    tamu Repository record for Modeling of Electronically Commutated Motor Controlled Fan-powered Terminal Units (opens in a new tab)

  2. Modeling of ECM Controlled Series Fan-powered VAV Terminal Units

    … (FPTUs) were developed based on models of the primary, plenum, fan airflow and the fan power consumption. The experimental setups and test procedures were developed respectively for primary, plenum and fan airflow to test each component of the FPTUs at typical design pressures and airflows. Two …

    tamu Repository record for Modeling of ECM Controlled Series Fan-powered VAV Terminal Units (opens in a new tab)

  3. Simulation-based study on CO2-based demand controlled ventilation strategies for multiple zone variable air volume systems

    … control strategies with energy simulation and airflow simulation. For all three control strategies proposed and developed in this research, CO2 sensors, occupancy-sensors, and airflow measurement were used to calculate the required OA rate to each zone. Those zones without any sensors were …

    nebraska Repository record for Simulation-based study on CO2-based demand controlled ventilation strategies for multiple zone variable air volume systems (opens in a new tab)

  4. Performance of ECM Controlled VAV Fan Powered Terminal Units

    Empirical performance models of fan airflow, primary airflow and power consumption were developed for series and parallel variable air volume fan powered terminal units. An experimental setup and test procedure were created to test the terminal units at typical design pressures and airflows. Each …

    tamu Repository record for Performance of ECM Controlled VAV Fan Powered Terminal Units (opens in a new tab)

  5. Biomechanical Models of Human Upper and Tracheal Airway Functionality

    … tract, in other words, the airway, is the primary airflow path for several physiological activities such as coughing, breathing, and sneezing. Diseases can impact airway functionality through various means including cancer of the head and neck, Neurological disorders such as Parkinson's …

    ucf Repository record for Biomechanical Models of Human Upper and Tracheal Airway Functionality (opens in a new tab)

  6. Bench-scale fire toxicity measurements of polymers and cables

    … of secondary air into the furnace tube at low primary flows which alters the preset fire conditions. This can be partially overcome by the use of an orifice plate with appropriate outlet size. Thus Casico power cable has been investigated in the steadystate tube furnace using under-ventilated …

    cent-lancashire Download PDF for Bench-scale fire toxicity measurements of polymers and cables (opens in a new tab)

  7. Modelování proudění vzduchu ve spalovací komoře ZKG

    Náplní předkládané práce je popis chemických a fyzikálních vlastností biomasy, metod energetických přeměn biomasy, procesů probíhajících při spalování biomasy a především proudění spalovacího vzduchu. Součástí této práce je modelování proudění spalovacího vzduchu spalovací komorou pomocí metody …

    brno-tech Repository record for Modelování proudění vzduchu ve spalovací komoře ZKG (opens in a new tab)