Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 70 for “"primary beam"”.
-
Optimization of primary beam for x-ray dual-mode imager comprising radiography and coherent scatter
… devices use both coherently-scattered x rays and primary to acquire images. In our system, the same detector is used for primary and scatter. The primary information being detected post object must be attenuated so that both the primary and scatter are within the detector’s dynamic range. …
-
ISOTOPE HARVESTING OF AQUEOUS PHASE IONS FROM HEAVY-ION FRAGMENTATION FACILITIES FOR THE PRODUCTION OF A Ca-47/Sc-47 GENERATOR
… in the future at the Facility for Rare Isotope Beams (FRIB), a supply of Ca-47, the parent of Sc-47, can be produced on a regular basis when the Ca-48 primary beam is used. While the main function of this accelerated primary beam is to produce a user-specified secondary radioactive beam for …
-
Magnetic sector deflector aberration properties for low- energy electron microscopy
… electrons. This involves the separation of the primary beam and the scattered electrons using a circular magnetic sector deflector. Simulations predict a primary beam probe radius of a few nm, and this is essentially confirmed in experiments carried out with a stand alone magnetic sector …
-
ELECTRON BEAM TESTING OF INTEGRATED CIRCUITS USING A MODIFIED SCANNING ELECTRON MICROSCOPE
… and have smaller structures. The electron beam has been identified as the only usable alternative for probing VLSI devices. The electron beam is a easily positioned, high resolution, nonloading and nondestructive probe. A conventional scanning electron microscope (SEM) can be used for …
-
X-ray extinction in piezo electric crystals
… passes through the crystal in both the secondary beams and the primary beam;Etching the surfaces of the crystal plates decreases their reflecting power for x-rays but also increases the strength of oscillation of the crystal. The effect on quartz is very pronounced, the effect of etching is …
-
Polarization in p-p elastic scattering
… energy cyclotron. Data were taken at five primary beam energies, 500, 467, 425, 367, and 307 MeV, and for the first time hydrogen was used both as polarizer and analyser.
-
Characterization of X-ray transmission and scattering during equine radiology procedures at the Johnson Family Equine Hospital
… of exposure to ionizing radiation, directly from primary beams and indirectly from scattered beams. Hence, radiation workers are enrolled in a radiation dosimetry program to comply with regulations and effectively track exposures. Because X-ray radiation is used daily for diagnostics and …
-
Conservation of charge in secondary electron emission test stand
… electron emission (SEE) can potentially lead to beam instabilities, material degradation and r.f. breakdown. The part SEE studios have deduced secondary electron yield by invoking a conservation of charge without the need to experimentally account for all measurables. In the spatial distribution …
-
The Straggling Green's Function Method for Ion Transport
… and laboratory results for an 56Fe ion beam with average energy at the target of one GeV/amu or more are presented for various targets. Quantities compared are the energy deposited spectra for an Aluminum target and Graphite-Epoxy mix target, the fraction of primary beam surviving and …
-
Spectrometer attachments for the scanning electron microscope
… energy loss spectrum (EELS) analysis for the primary beam penetrating thin samples. Normally, such experiments are only carried out in transmission electron microscopes. Experimental results presented in this theses show that such techniques are feasible inside a conventional SEM, and can be …
-
DIFFERENTIAL CROSS SECTIONS FOR NEUTRAL-NEUTRAL COLLISIONS
… cross sections have been measured over a primary beam energy range of 500eV to 5000eV for the scattering of atomic hydrogen, helium, and oxygen on targets of N(,2), O(,2), H(,2), and He at laboratory angles between 0.08 degrees and 5 degrees. These differential cross sections provide …
-
Collectivity of exotic silicon isotopes
… in East Lansing, Michigan. The secondary beams were produced by the fragmentation of a <super>48</super>Ca primary beam guided onto a high-Z secondary target. De-excitation gamma-rays, indicative of the inelastic process, were detected around the secondary target position with the …
-
Studies of oxide desoption from GaAs by diffuse electron scattering and optical reflectivity
… carried out in a VG V80H MBE system under a As4 beam equivalent pressure of 1.5 x 10⁻⁵ ton. Measurement of diffuse light scattering using a HeNe laser shows an abrupt and non-reversible increase in the scattered light intensity during the oxide desorption. This suggests the surface is …
-
Study of Secondary Electron Emission from Niobium at Cryogenic Temperatures
… distribution from niobium metal due to incident primary electrons. The experiments on the niobium sample are performed in an environment close to that present in a superconducting accelerator cavity. The experiment is performed in a vacuum chamber capable of achieving ultra high vacuum levels of …
-
Study of low energy electron inelastic scattering mechanisms using spin sensitive techniques
… surfaces and thin films. In these experiments, a beam of spin polarized electrons from a GaAs source is directed on the sample surface, and the spin polarization and intensity are measured as a function of energy loss and scattering angle by a Mott electron polarimeter coupled with a concentric …
-
A calibration methodology for energy dispersive X-ray fluorescence measurements based upon synthetically generated reference spectra
… number, X-ray tube voltage, X-ray tube current, primary beam filter, and carpet characteristics. For this application, XRF calibrations must be performed for carpets of all styles and types. However, preparing actual carpet calibration samples is expensive. This research introduced a methodology …
-
No evidence for millimeter continuum source overdensities in the environments of z [greater than approximately] 6 quasars
… of 35 bright quasars at 6 < z < 7 and search the primary beam for excess continuum emission as evidence for early protoclusters. We compare the detection rates of continuum sources at [greater than or equal to] 5σ significance in the fields surrounding the quasars (A [subscript eff] = 4.3 arcmin²) …
-
Electron Energy Spectrometers for the Scanning Electron Microscope
… based upon the use of a circular magnetic sector beam separator, suitable for SEMs that use electric/magnetic field objective lenses. These kinds of SEMs are able to obtain high image resolution at low primary beam voltages (1 kV or less). The magnetic beam spectrometer is designed to capture the …
-
Addressing current limitations in dual-energy computed tomography
… with a spatially-varying pattern, known as a primary beam modulator, to enable single-scan DECT on a conventional CT scanner. Phantom studies demonstrate that PM-DECT retains a high level of spatial resolution compared to conventional CT scans and can achieve electron density values with …
-
An XPS Study of the Effect of Ion Bombardment on Transition Metal Oxides
… Nb2O5, Ta2O5 and WO3. In order to establish the beam induced effects, it is necessary to characterize the unbombarded oxide surface. For each oxide this has been carried out by determination of the binding energies associated with the core-electron levels of the metal and oxygen in various …
Page 1 of 4