Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"projection domain"”.

  1. Projection-Domain Low-Count Quantitative SPECT (LC-QSPECT) Methods for Radiopharmaceutical Therapies (RPTs)

    … in α-RPT. To address these, we developed a projection-domain low-count quantitative SPECT (LC-QSPECT) method that estimates regional uptake directly from projection data while accounting for multiple image degrading effects in α-RPT. Clinically realistic simulation studies, including an in …

    wustl Repository record for Projection-Domain Low-Count Quantitative SPECT (LC-QSPECT) Methods for Radiopharmaceutical Therapies (RPTs) (opens in a new tab)

  2. Modulation of microtuble dynamics by the microtubule-associated protein MAP1a

    … fragments that contained the microtubule-binding domain were shown to associate with microtubules. MAP1a fragments containing portions of the projection domain promoted growth and stability of microtubules. Truncated fragments containing different regions of the projection domain of MAP1a …

    ottawa-retro Repository record for Modulation of microtuble dynamics by the microtubule-associated protein MAP1a (opens in a new tab)

  3. Algorithms for Quantitative Imaging with Advanced Cone-Beam Computed Tomography Configurations

    … task involving areal BMD quantification in the projection domain. Results show that material decomposition accuracy is highly sensitive to small scatter-induced biases, especially for DE protocols with poor spectral separation. This finding motivated the development of a high-fidelity …

    jhu Repository record for Algorithms for Quantitative Imaging with Advanced Cone-Beam Computed Tomography Configurations (opens in a new tab)

  4. X-ray CT scatter correction by a physics-motivated deep neural network

    … and correct for the scatter in the obtained projection measurements. They incorporate both an initial reconstruction of the object of interest and the scatter-corrupted measurements related to it. They use a common specific deep neural network architecture and a cost function adapted to the …

    uiuc Repository record for X-ray CT scatter correction by a physics-motivated deep neural network (opens in a new tab)

  5. Error-Driven Density Control for Compact Gaussian Splatting under Sparse Supervision

    … density control designed to focus primitives on projection-domain error under sparse-view ambiguity. On the R2-Gaussian benchmark (15 synthetic volumes and three real-world objects evaluated at 25/50/75 views), the tomography method reduces primitive count and improves efficiency: on real data at …

    wilfrid-laurier Repository record for Error-Driven Density Control for Compact Gaussian Splatting under Sparse Supervision (opens in a new tab) Download PDF for Error-Driven Density Control for Compact Gaussian Splatting under Sparse Supervision (opens in a new tab)

  6. Simulation and Modeling for UHR-MDCT and Photon-Counting CT

    … materials: bone and water were performed in projection domain and the bias of estimated line integrals in the presence of single channel scatter were assessed. This scatter study enables improvements in the accuracy of tissue composition and contrast agent quantification in PCCT.

    jhu Repository record for Simulation and Modeling for UHR-MDCT and Photon-Counting CT (opens in a new tab)

  7. Improving cone-beam CT image quality using non-circular orbits

    … bias and identifies the conditions under which a projection-domain proxy metric can guide orbit design. The work spans bench experiments, phantom and cadaver studies on two clinical Siemens robotic C-arm platforms, and simulation studies of spectral CBCT. The methods and findings provide a …

    jhu Repository record for Improving cone-beam CT image quality using non-circular orbits (opens in a new tab) Embargoed until 2027-08-01

  8. IMPROVED IMAGE QUALITY IN CONE-BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED INTERVENTIONS

    … simulation platform to generate realistic CBCT projections (e.g., as training data for deep learning approaches); (ii) a new projection domain statistical noise model to improve the noise-resolution tradeoff in model-based iterative reconstruction (MBIR); (iii) a novel method to avoid CBCT metal …

    jhu Repository record for IMPROVED IMAGE QUALITY IN CONE-BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED INTERVENTIONS (opens in a new tab)

  9. Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy

    … reconstruction or image restoration in the CBCT projections. Performance of three statistical iterative image reconstruction algorithms was compared through the noise-resolution-tradeoff analysis. Results of the comparison study suggested that different algorithms were favored in different …

    utswmed Repository record for Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy (opens in a new tab)

  10. Deep Learning for CT Image Enhancement and Segmentation: Metal Artifact Reduction and Airway Segmentation

    … task in design, and semantic constraint from the projection domain. Domain-adapted instance normalization is employed to bridge the domain gap between these two sources of data since the proposed model is trained on the dataset combined with simulated and clinical metal-affected images. …

    unsw Repository record for Deep Learning for CT Image Enhancement and Segmentation: Metal Artifact Reduction and Airway Segmentation (opens in a new tab)

  11. Study of the function of C-terminal tail of tau and targeted degradation of TDP-43

    … lobar degeneration (FTLD). Tau is a multi-domain protein, comprising an amino terminal proline-rich projection domain, followed by microtubule-binding repeats and a carboxyl terminal tail region (CTTR). Little is known about the functional relevance of the CTTR. In disease, tau becomes …

    unsw Repository record for Study of the function of C-terminal tail of tau and targeted degradation of TDP-43 (opens in a new tab)

  12. Deep Learning Based High-Resolution Statistical Downscaling to Support Climate Impact Modelling

    … dataset to improve Species Distribution Models’ projections. The objectives are connected to the three articles that support this cumulative dissertation. Its scope is limited to the Free State of Saxony, Germany, where local high-resolution climate data and high-quality observations of …

    qucosa-diss

  13. Deep Learning with Constraints and Priors for Improved Subject Clustering, Medical Imaging, and Robust Inference

    … Based on this observation, we propose a dual-domain learning approach to CT metal artifact reduction. We design and implement a novel Radon inversion layer that allows gradients in the image domain to be backpropagated to the projection domain. Experiments conducted on both simulated datasets …

    maryland Repository record for Deep Learning with Constraints and Priors for Improved Subject Clustering, Medical Imaging, and Robust Inference (opens in a new tab)

  14. Data and image domain deep learning for computational imaging

    … We use deep learning in both the sensor data domain and the image domain to develop new fast and efficient algorithms to achieve superior quality imagery. Metal artifacts are ubiquitous in both security and medical applications. They can greatly limit subsequent object delineation and …

    bu Repository record for Data and image domain deep learning for computational imaging (opens in a new tab)

  15. Deep Learning-based CBCT Projection Interpolation, Reconstruction, and Post-processing for Radiation Therapy

    … studies were conducted to reduce the number of projections (sparse sampling) to lower the imaging dose while maintaining good image quality and fast reconstruction speed. Conventionally, a CBCT volume is reconstructed analytically with the Feldkamp Davis Kress (FDK) algorithm that backprojects …

    duke Repository record for Deep Learning-based CBCT Projection Interpolation, Reconstruction, and Post-processing for Radiation Therapy (opens in a new tab)

  16. Redukce šumu v tomografických datech s vysokým rozlišením

    Vzhledem ke komplexnosti procesu akvizice dat výpočetní tomografie (CT) je šum v rentgenových snímcích nevyhnutelný a může vést ke zkreslení získané informace. Proto by měl být co nejvíce potlačen. Dosud se výzkum zaměřoval především na redukci šumu v CT datech u lékařských CT s nízkými dávkami, …

    brno-tech Repository record for Redukce šumu v tomografických datech s vysokým rozlišením (opens in a new tab)

  17. Quantitative SPECT Image Reconstruction using an Accelerated Monte Carlo based Maximum A-Posteriori (MAP) Algorithm

    … medium energy collimator. A comparison in the projection domain was then performed in terms of spatial resolution, sensitivity, image profiles and energy spectra. The study has shown percent differences of between 3−5% in sensitivity between CFD-SIMIND and GATE with mean universal image quality …

    mcmaster Repository record for Quantitative SPECT Image Reconstruction using an Accelerated Monte Carlo based Maximum A-Posteriori (MAP) Algorithm (opens in a new tab)