Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 18 of 18 for “"prompt gamma rays"”.
-
Secondary prompt gamma-rays to improve proton range verification
… of this research is to evaluate the secondary prompt gamma (PG) yield from proton therapy at high characteristic energies from MC model simulations and experimental data. Recent studies indicate that target composition influences PG characteristic energy and yield, and the quantification of PG …
-
Instrumentation of CdZnTe detectors for measuring prompt gamma-rays emitted during particle therapy
… types of tumors. In comparison with the use of X-rays or gamma-rays, particle therapy has the advantage that the dose distribution in the patient can be precisely controlled. Tissue or organs lying near the tumor will be spared. A verification of the treatment plan with the actual dose deposition …
-
Treatment verification in proton therapy based on the detection of prompt gamma-rays
… of range assessment via the detection of prompt gamma-rays, a side product emitted due to proton-tissue interaction. In the first part, the concept of measuring the spatial prompt gamma-ray emission profile with a Compton camera is investigated with a prototype system consisting of a …
-
Radiative neutron capture in I___ß
The prompt gamma rays and induced activity from the reaction I127(n,r)I128 are studied for neutron energy of 0.2 Mev to 1.91 Mev using a NaI(Tl) crstal both as target and detector. The relative cross sections calculated from both the prompt gamma ray and the induced activity data show good …
-
Nuclear methods for real-time range verification in proton therapy based on prompt gamma-ray imaging
… therapy and limits its ultimate aspirations. Prompt gamma rays, a by-product of the irradiation that is correlated to the dose deposition, are reliable signatures for the detection of range deviations and even for three-dimensional in vivo dosimetry. In this work, two methods for Prompt …
-
Monte Carlo Simulation of Thallium-Bromide Semiconductor Detector for Range Verification of a Carbon Ion Radiotherapy Beam through Prompt Gamma-Ray Detection
… to evaluate TlBr performance in the detection of prompt gamma-rays generated from the irradiation of a Polymethyl methacrylate (PMMA) phantom with carbon ions. TlBr was able to detect the prompt gamma ray profiles of three different materials (cortical bone, adipose tissue, PMMA) with correlation …
-
Prompt gamma-ray imaging of nanoparticles for in vivo range verification in proton therapy
… protons with the detection of the characteristic prompt gamma-rays emitted by the nanoparticles. To investigate the feasibility of performing prompt gamma-ray imaging using characteristic gamma rays from nanoparticles, a magnetite (Fe3O4) target was developed in house, consisting of a solution of …
-
Toward the Clinical Application of the Prompt Gamma-Ray Timing Method for Range Verification in Proton Therapy
The prompt gamma-ray timing (PGT) method offers a relatively simple approach for range verification in proton therapy. Starting from the findings of previous experiments, several steps toward a clinical application of PGT have been performed in this work. First of all, several scintillation …
-
Measuring cross-section data for prompt gammas emitted during proton-nucleus collisions
… measurement. The detection of secondary prompt gamma rays have been proposed as an in-situ method to determine the proton range since the location of the prompt gamma emission is strongly correlated with the proton depth dose profile. This correlation has been confirmed in both …
-
Characterization of ²³⁹Pu with coincidence and anticoincidence methods
… and anticoincidence techniques, including gamma-gamma coincidence and Compton suppression, have been used to effectively characterize many isotopes. However, these methods have not been thoroughly applied for ²³⁹Pu determination. Since this isotope has several low intensity gamma rays in …
-
Range uncertainty reductions in proton therapy and associated benefits for patients with brain or skull base tumors
… be achieved in a multitude of different ways. Prompt gamma-ray spectroscopy - i.e., measurements of prompt gamma-rays emitted as a result of proton irradiation - allows proton ranges to be verified in real time. The elemental composition of the irradiated tissue can be determined …
-
In vivo detection of gadolinium by prompt gamma neutron activation analysis: An investigation of the potential toxicity of gadolinium-based contrast agents used in MRI
… <em>in vivo</em> gadolinium (Gd) content by prompt gamma neutron activation analysis (PGNAA). PGNAA is a quantitative measurement technique that is completely non-invasive. Gadolinium has the highest thermal neutron capture cross section of all the stable elements. Gadolinium-based contrast …
-
Lifetime of positive electrons in metals
… the course of a day. A resolution time for the prompt gamma rays of Co⁶⁰ of 0.8 nanoseconds was readily obtained. In addition, the time sorter was characterised by a linear time calibration over the range involved in the lifetime measurements of one to ten nanoseconds. The absolute lifetime of …
-
Development and performance evaluation of detectors in a Compton camera arrangement for ion beam range monitoring in particle therapy
… by means of the detection of secondary prompt gamma rays, resulting from nuclear reactions between the particle beam and the biological tissue. The purpose of our project is to develop and commission an imaging system based on a Compton camera detector arrangement which could monitor in …
-
Development of a prompt γ-ray timing system including a proton bunch monitor for range verification in proton therapy
… approach for range verification, the prompt γ-ray timing (PGT) measures the time distribution of the promptly produced γ-rays using fast uncollimated scintillation detectors. However, the measured time spectra of the prompt γ-rays (PGs) are sensitive to phase instabilities between the …
-
Development of a Gamma-Ray Detector based on Silicon Photomultipliers for Prompt Gamma Imaging and High-Energy Spectroscopy
… positron emission tomography (PET) and prompt gamma imaging (PGI) are the most promising methods for in vivo range verification. PET and PGI are indirect approaches to measure protons penetration depth inside patients because they aim to detect secondary particles resulting from the …
-
A new prompt gamma spectroscopy-based approach for range verification in proton therapy
… biological washout, and the background due to prompt radiation originated from other reaction channels. These issues have been partly resolved by the use of in-beam PET scanners, which measure annihilation photons during the treatment. One of the most advanced versions is the INSIDE (INnovative …