Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 17 of 17 for “"prompt-gamma imaging"”

  1. Positron enhanced prompt gamma imaging

    … cancerous area but instead to healthy tissue. Prompt Gamma Imaging (PGI) is a technique that has been developed to reconstruct the dose deposition, using a Compton Camera (CC). PGI uses the prompt ys produced by inelastic scatters between the proton beam and nuclei within the target. These y …

    cape-town Repository record for Positron enhanced prompt gamma imaging (opens in a new tab)

  2. Towards the application of prompt-gamma imaging in online adaptive proton therapy

    … zusätzliche Verifikationsmethode, wobei sich die Prompt-Gamma-Bildgebung (engl. prompt-gamma imaging, PGI) als besonders vielversprechend erwiesen hat. Diese Dissertation hatte zum Ziel, PGI für die Anwendung in der OAPT weiterzuentwickeln. Der PGI-Workflow wurde wesentlich optimiert und …

    qucosa-diss Repository record for Towards the application of prompt-gamma imaging in online adaptive proton therapy (opens in a new tab)

  3. Automated evaluation of prompt gamma imaging data for treatment verification in adaptive proton therapy

    … thesis investigated the automatic evaluation of prompt gamma imaging (PGI) range verification data using artificial intelligence (AI). For this purpose, AI-based approaches of varying complexity were developed to detect and classify treatment deviations based on realistically simulated PGI data …

    qucosa-diss Repository record for Automated evaluation of prompt gamma imaging data for treatment verification in adaptive proton therapy (opens in a new tab)

  4. Automatic classification of treatment-deviation sources in proton therapy using prompt-gamma-imaging information

    Prompt-gamma imaging (PGI) was proposed in the 2000s as a promising in vivo range-verification method to maintain the physical advantage of proton beams by reducing unwanted range-uncertainties. Recently, PGI with a slit camera has been successfully implemented in clinical application. Despite its …

    qucosa-diss Repository record for Automatic classification of treatment-deviation sources in proton therapy using prompt-gamma-imaging information (opens in a new tab)

  5. A new treatment planning concept accounting for prompt gamma imaging for proton range verification

    … Wasser), oder durch anatomische Veränderungen. Prompt-Gamma-Bildgebung (PG) eröffnet die Möglichkeit, die Protonenreichweite in vivo zu beobachten, indem Prompt-Gammas detektiert werden, die durch Kernrelaxation innerhalb des Strahlengangs emittiert werden. Studien haben gezeigt, dass die …

    lmu-germany Repository record for A new treatment planning concept accounting for prompt gamma imaging for proton range verification (opens in a new tab)

  6. Implementation and characterization of the data acquisition system of a Compton camera for prompt gamma imaging in protontherapy

    … la délivrance de dose en imageant l’émission des gamma prompts issus des collisions inélastiques entre les particules du faisceau et les noyaux cibles. Ceci requiert de détecter les rayons gamma en utilisant une collimation soit mécanique soit électronique résultant de leurs interactions Compton …

    star-france Repository record for Implementation and characterization of the data acquisition system of a Compton camera for prompt gamma imaging in protontherapy (opens in a new tab)

  7. Development of a Gamma-Ray Detector based on Silicon Photomultipliers for Prompt Gamma Imaging and High-Energy Spectroscopy

    … positron emission tomography (PET) and prompt gamma imaging (PGI) are the most promising methods for in vivo range verification. PET and PGI are indirect approaches to measure protons penetration depth inside patients because they aim to detect secondary particles resulting from the …

    trento Repository record for Development of a Gamma-Ray Detector based on Silicon Photomultipliers for Prompt Gamma Imaging and High-Energy Spectroscopy (opens in a new tab)

  8. Evaluierung eines Detektionssystems für prompte Gammastrahlung zur Behandlungskontrolle bei klinischen Protonentherapiebestrahlungen

    … Reichweiteverifikationssystems auf Grundlage von Prompt-Gamma-Imaging (PGI) zur Behandlungskontrolle untersucht. Dafür wurden Messungen mit einem PGI-System während Prostata- und Kopf-Hals-Tumor-Bestrahlungen durchgeführt und retrospektiv ausgewertet. Einerseits konnte dabei mittels PGI die …

    qucosa-diss Repository record for Evaluierung eines Detektionssystems für prompte Gammastrahlung zur Behandlungskontrolle bei klinischen Protonentherapiebestrahlungen (opens in a new tab)

  9. Imagiologia por raios gama espontâneos ortogonais para verificação do alcance de feixes de hélio.

    … to evaluate the applicability of the Orthogonal Prompt Gamma Imaging (O-PGI) technique for in vivo range monitoring of 4He ion beams at energies of 70, 130 and 200 MeV/u through GEANT4 simulations. The methodological approach included modelling a homogeneous PMMA phantom and implementing a …

    coimbro Repository record for Imagiologia por raios gama espontâneos ortogonais para verificação do alcance de feixes de hélio. (opens in a new tab)

  10. Simulação de uma câmara multi-fatia de raios gama para determinação do alcance do feixe de protões em irradiação pélvica

    … vivo monitoring system based on the orthogonal prompt gamma imaging technique. This technique makes use of orthogonal prompt gamma rays, produced in proton-nuclear reactions within the body. Previous simulations and phantom-based experimental results, using 130 MeV proton beams, have shown to …

    coimbro Repository record for Simulação de uma câmara multi-fatia de raios gama para determinação do alcance do feixe de protões em irradiação pélvica (opens in a new tab)

  11. Proton Range Verification for Irradiation of Anthropomorphic Phantoms Implemented in Geant4 Monte Carlo Simulations

    … out: positron emission tomography (PET) and prompt gamma imaging (PGI). PET utilizes the positron emitting isotopes produced during proton interactions to provide real-time imaging and verify the distribution of the dose delivered. PGI, on the other hand, uses prompt gamma-rays emitted from …

    coimbro Repository record for Proton Range Verification for Irradiation of Anthropomorphic Phantoms Implemented in Geant4 Monte Carlo Simulations (opens in a new tab)

  12. Development and performance evaluation of detectors in a Compton camera arrangement for ion beam range monitoring in particle therapy

    … by means of the detection of secondary prompt gamma rays, resulting from nuclear reactions between the particle beam and the biological tissue. The purpose of our project is to develop and commission an imaging system based on a Compton camera detector arrangement which could monitor in …

    lmu-germany Repository record for Development and performance evaluation of detectors in a Compton camera arrangement for ion beam range monitoring in particle therapy (opens in a new tab)

  13. Optimization study of the performance of a LaBr3 monolithic scintillator in a Compton camera system

    … de dispersão de Compton dos raios gama prompt incidentes através de interações nucleares entre o feixe de partículas incidente e o tecido orgânico.A câmara de Compton da Ludwig-Maximilians-Universität Munich (LMU), sob estudo nesta tese, é composta por um detetor de dispersão (que …

    coimbro Repository record for Optimization study of the performance of a LaBr3 monolithic scintillator in a Compton camera system (opens in a new tab)

  14. Monitorização de terapia com protões com imagiologia por raios gama ortogonais: estudo da irradiação na cabeça

    A prototerapia (PT) está a tornar-se cada vez mais uma ferramenta para trata- mento de tumores não metastizados. Isto é devido à capacidade que a PT tem de depositar uma grande quantidade da energia do feixe no final do seu alcance, o pico de Bragg (BP). Apesar de demonstrar resultados clinicamente …

    coimbro Repository record for Monitorização de terapia com protões com imagiologia por raios gama ortogonais: estudo da irradiação na cabeça (opens in a new tab)

  15. Deep Learning-based Onboard Image Guidance and Dose Verification for Radiation Therapy

    … the clinical constraints on acquisition time and imaging dose. Radiation-induced acoustic (RA) imaging and prompt gamma (PG) imaging are two promising methods to reconstruct 3D dose deposition noninvasively in real-time during the treatment, but their images are severely distorted by the …

    duke Repository record for Deep Learning-based Onboard Image Guidance and Dose Verification for Radiation Therapy (opens in a new tab)

  16. Investigations on multilateration of ionoacoustic signals for localisation of the bragg peak in pre-clinical research

    … this form of treatment. While X-rays and gamma rays (photon therapy) are the standard approach, proton therapy has emerged as a valuable alternative. Proton therapy is renowned for its ability to provide a more conformal dose delivery. Proton therapy’s superiority over photon therapy is …

    lmu-germany Repository record for Investigations on multilateration of ionoacoustic signals for localisation of the bragg peak in pre-clinical research (opens in a new tab)