Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 25 for “"prosthetic valves"”.

  1. A Cost-Effective Method for Fabricating Prosthetic Valves for Patient-Specific In-Vitro Studies

    … models less representative of patient-specific valves. These difficulties can be overcome using particle image velocimetry (PIV) in tandem with a mock circulatory loop (MCL). Although this system enables direct experimentation and evaluation of patient-specific hemodynamics, challenges remain, …

    unt Repository record for A Cost-Effective Method for Fabricating Prosthetic Valves for Patient-Specific In-Vitro Studies (opens in a new tab)

  2. Drag Reduction in Prosthetic Aortic Valves Using High Polymer Additives

    Presently used prosthetic valves although capable of restoring the patient to a nearly normal life may cause significant hemodynamic complications, many of which are directly related to turbulent flow in and around the valve. The ultimate solution is to develop new prosthetic valve designs. …

    clemson Repository record for Drag Reduction in Prosthetic Aortic Valves Using High Polymer Additives (opens in a new tab)

  3. Design and Testing of a Linearly Actuated Pulsatile Pump for Ventricular Assist

    … the LAPP has a single translating part plus two prosthetic valves. To aid in the design process, numerical models were developed using the commercial software packages COMSOL and FLUENT. Bench-top testing loops were also developed. The LAPP has been shown to be capable of providing pulsatile flow …

    houston Repository record for Design and Testing of a Linearly Actuated Pulsatile Pump for Ventricular Assist (opens in a new tab)

  4. Development, testing, and evaluation of the central-flow, double- leaflet heart valve

    A review of the literature revealed that 1) all prosthetic heart valves to date are plagued by certain problems, 2) all prosthetic valves in current clinical use are central-occlusion valves which do not effectively simulate natural valve action, and 3) the development of a true central-flow valve …

    vt Repository record for Development, testing, and evaluation of the central-flow, double- leaflet heart valve (opens in a new tab)

  5. In vitro comparative hydrodynamic study of heart valve bioprostheses under accelerated fatigue conditions and under physiological conditions

    … hydrodynamic performance of these prosthetic valves is compared when tested using each machine, in order to assess the determining conditions that exist for each case, and try to correlate them.</p><p>Pressure drop and pulsatile flow across valves are measured, using a real-time …

    njit Repository record for In vitro comparative hydrodynamic study of heart valve bioprostheses under accelerated fatigue conditions and under physiological conditions (opens in a new tab)

  6. Characterization of pulse duplicator model for testing of heart valves

    … of a pulse duplicator system for testing of prosthetic valves is described. The performance characteristics were evaluated by computing the input impedance of the system from the measured pressure and flow signals for different simulation configurations. The study has been further extended to …

    njit Repository record for Characterization of pulse duplicator model for testing of heart valves (opens in a new tab)

  7. Design and Development of a Novel Implantable Prosthetic Vein Valve

    … results from damaged (incompetent) one-way vein valves in leg veins. These valves normally allow forward flow of blood to the heart, and prevent blood from pooling at the feet. However, incompetent valves allow reflux of blood, causing clinical problems. There are few effective clinical therapies …

    gatech Repository record for Design and Development of a Novel Implantable Prosthetic Vein Valve (opens in a new tab)

  8. Interplay of Cardiovascular Disease and Renal Disease

    … disease. Chapters 2 and 3 focus on the optimal prosthetic valve in dialysis patients requiring valve replacement surgery. Chapter 2 is a systematic review and meta-analysis comparing the short and long-term outcomes of two prosthetic valves implanted in dialysis patients. Chapter 3 is a survey …

    mcmaster Repository record for Interplay of Cardiovascular Disease and Renal Disease (opens in a new tab)

  9. The Sheep as a Translational Model for Next Generation Valve Replacement Devices: A Multimodal Cardiac Imaging Study

    … valve replacement devices, or transcatheter valves, has ushered in a new era in the treatment of patients with valvular disease. Prior to clinical study, regulators require comprehensive in vivo safety studies of novel cardiac devices in large animal models. The domestic sheep model has been …

    umn Repository record for The Sheep as a Translational Model for Next Generation Valve Replacement Devices: A Multimodal Cardiac Imaging Study (opens in a new tab)

  10. Development of an In Vitro System for Evaluation of Prosthetic Vein Valves

    … exercise. In a healthy individual, the vein valves and muscle pumps of the extremities combine to allow for a reduction in venous pressure during exercise. Consistent high pressure in the leg can lead to disability, pain, and ulcer formation. Typical causes of chronic venous insufficiency are …

    clemson Repository record for Development of an In Vitro System for Evaluation of Prosthetic Vein Valves (opens in a new tab)

  11. Transcatheter and Surgical Aortic Valve Replacement for Severe Aortic Stenosis: Insights from Cardiovascular Magnetic Resonance Imaging

    … patient selection and the development of novel prosthetic valves to improve outcomes. Cardiovascular Magnetic Resonance (CMR) imaging is the investigative modality of choice for such a purpose. Objectives: To compare the impact of SAVR and TAVI upon aortic stiffness, right ventricular function …

    whiterose Download PDF for Transcatheter and Surgical Aortic Valve Replacement for Severe Aortic Stenosis: Insights from Cardiovascular Magnetic Resonance Imaging (opens in a new tab)

  12. Prosthetic Vein Valve: Delivery and In Vitro Evaluation

    … that affects the superficial and deep vein valves of the legs. When the valves become incompetent they allow reflux and subsequent pooling of blood. Current clinical therapies are only moderately; and therefore, the need for a better solution remains. Prosthetic venous valves were …

    gatech Repository record for Prosthetic Vein Valve: Delivery and In Vitro Evaluation (opens in a new tab)

  13. MACROPHAGE SECRETOME REGULATION OF AORTIC VALVE INTERSTITIAL CELLS

    … by this disease is total replacement with prosthetic valves. This presents a huge challenge for biomedical engineers as no functional tissue engineered replacement has been created. The closest biological analogue currently used for total valve replacement are porcine valves. Like their …

    cornell Repository record for MACROPHAGE SECRETOME REGULATION OF AORTIC VALVE INTERSTITIAL CELLS (opens in a new tab)

  14. Parametric design investigation on geometric orifice area and coaptation area of polymeric heart valves

    … cases to substitute the native valve with either prosthetic or mechanical heart valves. Prosthetic heart valves are designed after the native valves and can mimic the behavior of the native valves without disturbing the blood flow. However, their lifespan is limited to 10 to 15 years. Therefore, …

    ttu Repository record for Parametric design investigation on geometric orifice area and coaptation area of polymeric heart valves (opens in a new tab)

  15. Influence of anatomic valve conditions and coronary flow on aortic sinus hemodynamics

    … to evaluate the hemodynamic impacts of different prosthetic aortic valve implantations. In this work, experimental methods have been developed to study a broad range of aortic valve conditions, and computational models were also employed to validate and enhance experimental findings. An in vitro …

    colostate Repository record for Influence of anatomic valve conditions and coronary flow on aortic sinus hemodynamics (opens in a new tab)

  16. Characterisation of haemodynamic and vascular dysfunction in bicuspid aortic valve disease using advanced cardiovascular magnetic resonance imaging techniques

    … shear stress. By contrast, all subjects with bioprosthetic AVR had residual abnormal helical flow patterns (mainly marked right-handed helical flow), with similar rotational flow values to native BAV. Wall shear stress post-bioprosthetic AVR showed a similar pattern.</p> <p>These findings point …

    oxford Repository record for Characterisation of haemodynamic and vascular dysfunction in bicuspid aortic valve disease using advanced cardiovascular magnetic resonance imaging techniques (opens in a new tab)

  17. New diagnostic perspectives for cardiovascular infections – impact of FISHseq

    … performed within three specific CVI categories: prosthetic valve endocarditis (PVE), nonvalvular cardiovascular device-related infections (NCDI) and native valve endocarditis (NVE). In all three publications, retrospective analyses were performed. In each study surgically explanted material …

    fu-berlin Repository record for New diagnostic perspectives for cardiovascular infections – impact of FISHseq (opens in a new tab)

  18. Echokardiographische Langzeitbeurteilung der Funktion von perkutan implantierten Aortenklappenprothesen bei hochgradiger Aortenklappenstenose

    Hintergrund: Die Aortenklappenstenose stellt die häufigste therapiebedürftige Erkrankung der Herzklappen in den industrialisierten Ländern dar. Durch TAVI (transcatheter aortic valve implantation) ergibt sich für Hochrisikopatienten mit hochgradiger Aortenklappenstenose eine Therapiealternative zur …

    fu-berlin Repository record for Echokardiographische Langzeitbeurteilung der Funktion von perkutan implantierten Aortenklappenprothesen bei hochgradiger Aortenklappenstenose (opens in a new tab)

  19. The haemolytic complications of prosthetic heart valve replacement

    A study of the haemolytic complications of prosthetic heart valve replacement forms the subject of this thesis. A chronic traumatic intra-vascular haemolysis is the principal complication and its investigation constitutes the major part of this study. The history of haemolysis with intrcardiac …

    glasgow Download PDF for The haemolytic complications of prosthetic heart valve replacement (opens in a new tab)

Page 1 of 2