Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 77 for “"protection relays"”

  1. Adaptive Reconfiguration of Protection Relays to Accommodate Distributed

    … (DGs) requires the reconfiguration of the protection system of the distribution network (DN) in place. Increased integration of DGs in the DN can cause incorrect tripping and false non-tripping of the overcurrent (OC) protection relays in the DN as well as increased possibilities of faults …

    york Repository record for Adaptive Reconfiguration of Protection Relays to Accommodate Distributed (opens in a new tab)

  2. Design and Implementation of Overcurrent Protection Relays Test Bench

    … employed electromechanical and microprocessor protection relays, manual isolation and industrial circuit breakers, switches, variable autotransformer (VARIAC), voltmeters and ammeters. During the dismantling, a lot of equipment was retrieved for future possible use. This led to the idea of …

    wvu Repository record for Design and Implementation of Overcurrent Protection Relays Test Bench (opens in a new tab)

  3. Remote Monitoring and Control of Protection Relays via Programmable Logic Controller

    … (PLC) to wirelessly monitor and control power protection relays. The technologies surrounding power protection and industrial automation are ever evolving and have developed significantly in recent history. Industrial power applications call for consistent condition monitoring and status …

    calpoly Repository record for Remote Monitoring and Control of Protection Relays via Programmable Logic Controller (opens in a new tab)

  4. Enhancing the performance of distance protection relays under practical operating conditions.

    … the performance of modern numerical distance protection relays under complex, practical fault scenarios and operating conditions, in particular those associated with distance protection of closely-coupled parallel lines. Double-circuit and parallel transmission lines, in various topologies, …

    ukzn Repository record for Enhancing the performance of distance protection relays under practical operating conditions. (opens in a new tab)

  5. Investigating the performance of generator protection relays using a real-time simulator.

    … utilized to perform hardware-in-loop testing of protection relays and power system controllers for some years. However, hardware-in-loop testing of generator protection relays has until recently been limited by a lack of suitable dynamic models of synchronous generators in the real-time …

    ukzn Repository record for Investigating the performance of generator protection relays using a real-time simulator. (opens in a new tab)

  6. Excel-baserad beräkning och dokumentation av distansskyddsinställningar

    … thesis work describes the theory of distance protection relaying in 130 kV meshed distribution networks. The main aim of the thesis was to construct an Excel application for calculation and documentation of the settings for distance protection relays. The program is based on general methods …

    chalmers Repository record for Excel-baserad beräkning och dokumentation av distansskyddsinställningar (opens in a new tab)

  7. A study of the effect of harmonics in the system on the performance of residual current-operated circuit-breakers and electromechanical overcurrent relays

    … (RCCBs) have proved useful devices for the protection of both human beings against ventricular fibrillation and installations against fire. Although they work well with sinusoidal waveforms, there is little published information on their characteristics. Due to shunt connected non-linear …

    aston Repository record for A study of the effect of harmonics in the system on the performance of residual current-operated circuit-breakers and electromechanical overcurrent relays (opens in a new tab)

  8. Alternate Fault testing on a Bus on a Dynamic Position Vessel

    … offers an alternate and safer way to ensure the protection equipment is working properly by using a fault signal using from Programmable Logic Controller in conjunction with the protection relays. A working PSCAD model of Transocean's DEEPWATER CHAMPION was developed using a one line diagram. …

    vt Repository record for Alternate Fault testing on a Bus on a Dynamic Position Vessel (opens in a new tab)

  9. Implementation of the Security-Dependability Adaptive Voting Scheme

    … societal and economical impact. Power system protection relays make up a piece of these limits and can be important factors in preventing or causing a system blackout. The purpose of this thesis is to present a working implementation of an adaptive protection scheme known as the adaptive …

    vt Repository record for Implementation of the Security-Dependability Adaptive Voting Scheme (opens in a new tab)

  10. Impact of series compensation on the perfomance of distance protection on Eskom transmission grid.

    … of series capacitors and their over-voltage protection devices typically the Metal Oxide Varistors and Spark Gaps when installed on transmission lines, several problems are created for the distance protection relays. This is because series capacitors when used on transmission lines can have …

    ukzn Repository record for Impact of series compensation on the perfomance of distance protection on Eskom transmission grid. (opens in a new tab)

  11. Performance comparison of a permissive overreach transfer trip (POTT) scheme over IEC 61850 and hard-wire

    … of systems built from multivendor power protection relays. The standard describes the rules for integration of control, measurement, and protection functions within a power system network at the substation control levels. The standard was created with the idea of eliminating wiring in the …

    utc Repository record for Performance comparison of a permissive overreach transfer trip (POTT) scheme over IEC 61850 and hard-wire (opens in a new tab)

  12. Protection challenges in future converter-dominated power systems : investigation and quantification using a novel flexible modelling and hardware testing platform

    … thesis addresses anticipated (and documented) protection challenges that will be introduced by the domination of power electronics interfaces in future power systems. A flexible and programmable voltage source converter (VSC) model with controllable fault response has been developed and this is …

    strathclyde Repository record for Protection challenges in future converter-dominated power systems : investigation and quantification using a novel flexible modelling and hardware testing platform (opens in a new tab)

  13. Improved models of electric machines for real-time digital simulation

    … digital simulators to closed-loop testing of protection relays designed to protect synchronous machines during internal faults. To evaluate the inductances of synchronous machines, a winding function approach was developed in this thesis which is capable of taking into account both the actual …

    manitoba Repository record for Improved models of electric machines for real-time digital simulation (opens in a new tab)

  14. Proposição de um modelo para análise de fluxo de carga, curto-circuito e simulação de relés de produção

    … of transient phenomenon in operation of protection relays, and calibrate the enterprise's protections relays. For testing the model, some relays, actually, installed at COSERN were used

    brazil-ufrn Repository record for Proposição de um modelo para análise de fluxo de carga, curto-circuito e simulação de relés de produção (opens in a new tab)

  15. Development of a new pole–slip protection function for synchronous machines

    … during a pole-slip condition. All pole-slip protection relays currently on the market use the impedance pole-slip protection method to detect a pole-slip. No commercial relay currently available can predict accurately when a generator is about to experience a damaging pole-slip. All the …

    nwu-za Repository record for Development of a new pole–slip protection function for synchronous machines (opens in a new tab)

  16. Implementation of incremental quantities algorithm and improved distance function for the protection of highly penetrated power systems with inverter-based resources

    Protection relays and their algorithms have shown incorrect operations when facing conditions of low inertia and high penetration of inverter-based resources has been rapidly becoming a topic of interest in the state-of-the-art surrounding power systems reliability and protection. Several studies …

    uniandes Repository record for Implementation of incremental quantities algorithm and improved distance function for the protection of highly penetrated power systems with inverter-based resources (opens in a new tab)

Page 1 of 4