Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 310 for “"proton beam"”.
-
The 2nd generation proton beam writing
Proton beam writing (PBW) has the ability to fabricate high aspect ratio 3D micro/nano-structures with precise edges, smooth and straight side-walls. The newly developed 2nd generation PBW line has a very high lens demagnification (857 ? 130). An orthogonal free-standing grid with high side wall …
-
Waveguide fabrication using proton beam writing
Proton beam writing (P-beam writing) is an emerging direct-write lithographic technique that is being developed at the Centre for Ion Beam Applications (CIBA). Evolved from nuclear microscopy techniques less than a decade ago, it now boasts a wide spectrum of possible niche application areas, …
-
Control and characterization of a cyclotron proton beam
The cyclotron proton beam accelerator at the University of Missouri Research Reactor (MURR) is used for positron emission tomography (PET) applications. Pharmaceutical radioisotopes are produced and delivered to local hospitals for cancer diagnosis and nuclear imaging. The proton beam's energy is …
-
Searching for new physics with Fermilab’s proton beam
Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2025-10-20 without embargo terms
-
Proton beam writing applications in microfluidics and nanoimprint lithography
This thesis describes the development of proton beam writing for microfluidic applications.In first part of the thesis we used a focused beam of protons to fabricate throughdirect writing microfluidic structures in solid sheets of poly(methylmethacrylate)PMMA resist. The microchannels have been …
-
NANOFABRICATION USING OPTIMIZED PROTON BEAM WRITING AND MASKED ION LITHOGRAPHY
Proton Beam Writing (PBW) is a direct-write lithographic technique featuring minimal proximity effect coupled with uniform energy deposition in thin polymer layers. In this thesis, we present an optimized approach to nanofabrication using PBW. A spot size of 13 nm × 32 nm (STIM) was achieved using …
-
Fabrication of proton beam micromachined scaffolds for cell behaviour studies
… polymethylmethacrylate (PMMA) with a focused proton beam, typically 1 MeV protons with a beam spot size of 1??1A?m2. We observed that BAE (Bovine Aortic Endothelial) cells naturally aligned with and were guided along 3D ridges and grooves. By means of cell speed calculation, we found that BAE …
-
SINGLE CRYSTAL DIAMOND NANOFABRICATION AND MODIFICATION THROUGH PROTON BEAM WRITING
In this thesis, proton beam writing (PBW) was used to form a pattern in a resist material (e.g. HSQ), which was spin-coated on a Si or diamond substrate. After development, the resist pattern was employed as a mask to conduct reactive ion etching (RIE) to obtain Si or diamond nano-structures. …
-
METAL MOLD FABRICATION BY PROTON BEAM WRITING AND ITS APPLICATIONS
… this gap. Firstly, an advanced technology named proton beam writing was used in our research. Proton beam writing (PBW) is a mask-less, 3D fabrication lithographic technique which is developed at the Center for Ion Beam Applications (CIBA), Department of Physics, National University of Singapore. …
-
Stray Radiation Dose from X-ray and Proton Beam Radiation Therapies
… characterize the stray radiation from external beam radiation therapy, including megavoltage x-ray therapy and proton therapy. Chapter 1 gives a brief primer on radiation therapy and a summary of the state of knowledge regarding stray radiation exposures. In Chapter 2, we developed an analytical …
-
Evaluation of a Novel 3D Proton Beam Tracking System Utilizing Radar Imaging
<p>Proton therapy, a form of cancer treatment that involves the use of high-energy protons to destroy cancerous tissue, currently lacks a standardized method for physical quality assurance of the proton beam’s location, instead relying fully on computational simulations. The present thesis reports, …
-
Design and Simulation of a Passive-Scattering Nozzle in Proton Beam Radiotherapy
Proton beam radiotherapy is an emerging treatment tool for cancer. Its basic principle is to use a high-energy proton beam to deposit energy in a tumor to kill the cancer cells while sparing the surrounding healthy tissues. The therapeutic proton beam can be either a broad beam or a narrow beam. In …
-
The relative biological effectiveness (RBE) of a 200–MeV clinical proton beam
… proved to be beneficial over the last 10 years. Protons are regarded as being more advantageous because of their distinctive physical depth dose distribution that allows dose conformation to the tumor while sparing normal tissue. In this study, the relative biological effectiveness (RBE) values …
-
Radiation retinopathy and optic neuropathy after proton beam therapy of choroidal melanoma
… retinopathy and optic neuropathy after proton beam irradiation in choroidal melanomas in a long-term follow-up with the focus on determining incidence rates, risk factors and visual prognosis. Methods: We evaluated 1085 patients with choroidal melanomas who received proton beam therapy …
-
Feasibility of in-beam MR imaging for actively scanned proton beam therapy
Proton therapy (PT) is expected to greatly benefit from the integration with magnetic resonance imaging (MRI). This holds true especially for moving tumors, as the combination allows tumor motion tracking and subsequently a gated treatment or real-time treatment adaptation. At the time of starting …
-
DEVELOPMENT OF AN ELECTRON IMPACT GAS ION SOURCE FOR PROTON BEAM WRITING APPLICATIONS
… found to be comparable to the injecting electron beam reduced brightness. This leads to the design of a compact proton beam lithography, with sub-10 nm writing feature, and writing speed comparable to Electron Beam Lithography.
-
Feasibility of On-line Proton Beam Range Verification with Positron Emission Tomography Imaging
… imaging has been adopted clinically to verify proton beam range (BR) in proton therapy. Conventional approaches use off-line verification that verifies BR after delivery of full dose of a treatment fraction. This verification can be used to check the accuracy of current therapy retrospectively, …
Page 1 of 16